Xhibit
KIT, Down Converter, Active Antenna
10manufacturers in China registered for this device type
3catalogue numbers in this listing
Who Else Makes It
Concentrated in Guangdong (6), Jiangsu (1), Hebei (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Linxens Healthcare (Tianjin) Co., Ltd. | Jinnan District | Tianjin | Contract manufacturer | 7 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Orantech Inc. | Shenzhen | Guangdong | Contract manufacturer | 40 |
| Shenzhen Comen Medical Instruments Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Contec Medical Systems Co., Ltd. | Qinhuangdao | Hebei | Manufacturer | 22 |
| Guangdong Biolight Meditech Co., Ltd. | Zhuhai | Guangdong | Manufacturer | 19 |
| Shandong Corecare Technology Limited | Jinan | Shandong | Manufacturer | 2 |
Record
| Listed by | Spacelabs Healthcare (Washington), Inc |
|---|---|
| FDA product code | DSI |
| Device type | Detector And Alarm, Arrhythmia |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1025 |
| 510(k) | K141156 |
| Record published | 2018-08-10 |
| Record revised | 2023-10-05 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, manufacturing date, serial number |
| Storage | Storage environment temperature -40 to 75 °C |
| Distribution end date | 2016-12-08 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Xhibit Central | In distribution | |
| Xhibit Central | In distribution | |
| 96102 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Trulink | Spacelabs Healthcare (Washington), Inc | 160 |
| Fukuda Denshi | Fukuda Denshi Co., Ltd. | 30 |
| Q-Tel RMS | Mortara Instrument, Inc. | 20 |
| Detector And Alarm, Arrhythmia | Philips Medical Systems Hsg | 20 |
| ECG Electrodes | Philips Medical Systems Hsg | 19 |
| Seeq™ | Medtronic, Inc. | 18 |
| Life Sensing Instruments, Inc. | Life Sensing Instruments, Inc. | 17 |
| NIBP Cuffs | Philips Medical Systems Hsg | 14 |
| Waveline EZ+ | Avante | 11 |
| BodyGuardian | Preventice Technologies, Inc. | 10 |
| BodyGuardian Kit | Preventice Technologies, Inc. | 8 |
| Waveline Pro+ | Avante | 7 |
Showing 12 of 112. All products under Detector And Alarm, Arrhythmia
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Spacelabs Healthcare Ltd. | 510(k) number | 2026-06-04 | Class II | Unknown/Undetermined by firm | Due to off-the-shelf display port component that has audio/video failures | 6074 | |
| Spacelabs Healthcare Ltd. | 510(k) number | 2019-08-30 | Class II | Software Manufacturing/Software Deployment | The firm received reports of loss of audio alarm after a power failure or cable disconnection. The loss of audio for a telemetry patient could delay the recognition of an alarm condition. | 2197 units | 2024-04-18 |
| Spacelabs Healthcare Ltd. | 510(k) number | 2016-10-18 | Class II | Software design | The firm received reports of telemetry SpO2 numerics dropping off the Xhibit Central display. Desaturation, high, and low limit alarms work normally. | 348 units (292 units in the US and 56 units outside the US) | 2017-04-03 |
| Spacelabs Healthcare Ltd. | 510(k) number | 2016-08-25 | Class II | Software design | The firm received multiple reports of Xhibit Telemetry System going offline or locking up. In addition, short-duration asystole alarms may not display an audio and visual alarm as reported from a single Canadian hospital. | 798 units total (488 units in the US and 310 units outside U | 2017-03-13 |
| Spacelabs Healthcare Ltd. | 510(k) number | 2016-02-26 | Class II | Software in the Use Environment | The firm has received one report of values for patient height and weight being switched when input at the Xhibit Central Station, Model 96102, causing a bedside monitor Body Surface Area (BSA) calculation to be in error. | total 1075 units (614 units in the US and 461 outside the US | 2016-10-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.