Hypotension Decision Assist (HDA)

Hypotension Decision Assist (HDA) is clinical decision-support software for anesthesia professionals managing blood pressure during surgery. It receives continuous arterial-pressure…

Registry build 21.09.26

Hypotension Decision Assist (HDA) is clinical decision-support software for anesthesia professionals managing blood pressure during surgery. It receives continuous arterial-pressure waveforms and cardiovascular measurements from a separate multiparameter patient monitor. Its indicated patient group is adults aged eighteen or older whose arterial pressure is continuously monitored.

HDA presents graphs and numerical values, compares mean arterial pressure with clinician-set targets, and indicates when pressure is outside the selected range. Users can mark vasopressor administration and volume challenges on the pressure trend to place those events alongside the measurements.

Listed Item

Hypotension Decision Assist HDA-OR2 is a clinical decision support Software as a Medical Device (SaMD) that is installed upon a medically-rated touch-screen tablet computer. HDA-OR2 connects to a multi-parameter patient monitor supplied by other manufacturers, from which it acquires vital signs data continuously including the arterial blood pressure waveform and cardiovascular-related numeric parameters. HDA-OR2 continually processes this data to display, in graphical charts and numeric format, vital signs data and derived variables including mean arterial pressure (MAP), heart rate, systolic and diastolic blood pressure, cardiac output and systemic vascular resistance. HDA-OR2 compares MAP to user set targets to indicate when MAP is above or below the target range. It allows the user to mark the administration of vasopressors and volume challenges to the MAP trend.

Computer and Signal Processing

The software runs on a medical-grade touch-screen computer connected to the vital-signs monitor. It derives mean arterial pressure, cardiac output, systolic and diastolic pressure, and heart rate from the incoming arterial waveform. The display also includes systemic vascular resistance.

5manufacturers in China registered for this device type
2catalogue numbers in this listing
2510(k) clearances naming this product code

Who Else Makes It

Concentrated in Guangdong (4), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code DXG
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Orantech Inc. Shenzhen Guangdong Contract manufacturer 40
Shenzhen Comen Medical Instruments Co., Ltd. Shenzhen Guangdong Contract manufacturer 24

Record

Regulatory record for Hypotension Decision Assist (HDA)
Listed by Directed Systems Ltd, United Kingdom
FDA product code DXG
Device type Computer, Diagnostic, Pre-Programmed, Single-Function
Device class Class 2
Regulation 21 CFR 870.1435
Establishment Specification developer, Manufacturer
510(k) K190955
Record published 2020-06-22
Record revised 2026-07-21 (version 5)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries serial number

Catalogue Numbers

Catalogue numbers for Hypotension Decision Assist (HDA)
Catalogue number Size Status
HDA-OR1 In distribution
HDA-OR2 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
LiDCO Ltd Lidco Ltd. 133
LiDCO Lidco Ltd. 32
Transonic Transonic Systems, Inc. 31
Computer, Diagnostic, Pre-Programmed, Single-Function Edwards Lifesciences Technology Sarl 23
Retia Medical Retia Medical, LLC 17
EV1000 Edwards Lifesciences Technology Sarl 11
Computer, Diagnostic, Pre-Programmed, Single-Function GE Healthcare Finland OY 5
Pediasat Edwards Lifesciences Technology Sarl 4
LiDCO Masimo Corporation 4
ICU Medical ICU Medical, Inc 4
Cnap® Monitor 500 HD Cnsystems Medizintechnik GmbH 4
Vigileo Edwards Lifesciences Technology Sarl 3

Showing 12 of 39. All products under Computer, Diagnostic, Pre-Programmed, Single-Function

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K212529 2021-11-23
K190955 2019-11-27

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer