UltraviewSL

91496 Uvsl Command Module - Masimo

Registry build 21.09.26
5manufacturers in China registered for this device type
2catalogue numbers in this listing

Who Else Makes It

Concentrated in Guangdong (4), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code DXG
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Orantech Inc. Shenzhen Guangdong Contract manufacturer 40
Shenzhen Comen Medical Instruments Co., Ltd. Shenzhen Guangdong Contract manufacturer 24

Record

Regulatory record for UltraviewSL
Listed by Spacelabs Healthcare (Washington), Inc
FDA product code DXG
Device type Computer, Diagnostic, Pre-Programmed, Single-Function
Device class Class 2
Regulation 21 CFR 870.1435
510(k) K103142
Record published 2017-03-10
Record revised 2019-01-31 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, serial number
Storage Storage environment temperature -40 to 75 °C; Storage environment humidity 0 to 95 % RH
Distribution end date 2019-01-31

Catalogue Numbers

Catalogue numbers for UltraviewSL
Catalogue number Size Status
91496 Withdrawn
91496 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
LiDCO Ltd Lidco Ltd. 133
LiDCO Lidco Ltd. 32
Transonic Transonic Systems, Inc. 31
Computer, Diagnostic, Pre-Programmed, Single-Function Edwards Lifesciences Technology Sarl 23
Retia Medical Retia Medical, LLC 17
EV1000 Edwards Lifesciences Technology Sarl 11
Computer, Diagnostic, Pre-Programmed, Single-Function GE Healthcare Finland OY 5
Pediasat Edwards Lifesciences Technology Sarl 4
LiDCO Masimo Corporation 4
ICU Medical ICU Medical, Inc 4
Cnap® Monitor 500 HD Cnsystems Medizintechnik GmbH 4
Vigileo Edwards Lifesciences Technology Sarl 3

Showing 12 of 39. All products under Computer, Diagnostic, Pre-Programmed, Single-Function

Recalls Naming This Product

9 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of UltraviewSL
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Spacelabs Healthcare Ltd. 510(k) number 2026-03-26 Class II Process control Due to a manufacturing issue (i.e. malfunctioning of electrical Leakage tester). 57
Spacelabs Healthcare Ltd. 510(k) number 2026-02-27 Class II Component change control Multi-parameter command module has a circuit board issue and when in Auto mode, Cardiac Output (CO) measurement may activate early, resulting in Bad Curve error with no CO measurement or Irregular Curve error with CO measurement not automat 1790
Spacelabs Healthcare Ltd. 510(k) number 2023-04-12 Class II Component change control Command modules will display the following when parameter processing is suspended, depending on software version: 1) Older versions will have waveforms present with no alarms, 2) Newer versions have waveforms absent with no alarms. This may 1,088
Spacelabs Healthcare Ltd. 510(k) number 2016-07-01 Class II Vendor change control The firm has received multiple reports of the Non-Invasive Blood Pressure (NIBP) parameter becoming non-functional with an associated message (No Reading). In addition, there is one of the following three error messages: Inflate Error, HW E 3801 modules and 116 PCBAs & valves distributed in the US; 1 2017-05-22
Spacelabs Healthcare Ltd. 510(k) number 2015-04-21 Class II Software design Modules resetting. This failure mode happens when the Spacelabs Command Module is configured with the Masimo SpO2 option (-M), the Spacelabs Respiration option (-R) and the Masimo SpO2 PCBA, PN: 010-1136-02. With these two options and the M 1973 units total (1345 modules in the US and 604modules inte 2015-11-16
Spacelabs Healthcare Ltd. 510(k) number 2015-04-17 Class II Software design Ultraview SL Command Modules which were upgraded with the Masimo SpO2 Option, Model 91496-M was affected. Customer reported that during the time that the module is resetting (~10 seconds), monitoring of all parameters will be suspended. Up 1999 units total (1932 in the US and 67 international) 2015-11-13
Spacelabs Healthcare Ltd. 510(k) number 2014-05-08 Class II Software Manufacturing/Software Deployment A software anomaly causes temperature alarm limits to change to limits which are not physiologically possible and result in nuisance false positive alarms. 64 devices 2014-06-03
Spacelabs Healthcare Ltd. 510(k) number 2011-11-03 Not classified Process change control NIBP pump inside the Ultraview SL Command Module, Model 91496, became loose. The pump is suspended by the air hoses and electrical connections, but there can be enough movement to
damage internal components and cause the module to fail.
6722 units worldwide (3598 units in US and 3124 units outsid 2012-09-19
Spacelabs Healthcare Ltd. 510(k) number 2011-07-13 Not classified Software design One Spacelabs Medical Ultraview SL Command Module, Model 91496, was removed from customer due to software error. one unit 2012-01-20

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer