Abiomed 14fr Low Profile Introducer

The Abiomed 14 Fr Low Profile Introducer Set provides vascular access for introducing and removing the Impella CP catheter and ancillary devices. It is a sterile, single-use prescription…

Registry build 21.09.26

The Abiomed 14 Fr Low Profile Introducer Set provides vascular access for introducing and removing the Impella CP catheter and ancillary devices. It is a sterile, single-use prescription set containing an introducer sheath and tapered dilator compatible with a 0.035 inch guidewire.

The sheath remains in the vessel after the dilator is removed. Its proximal hub includes a hemostasis valve, three-way stopcock, flush port and suture pad. A coil-reinforced polymer sheath body provides the 14 Fr insertion profile, with a stainless-steel reinforcement coil supporting radiographic visibility.

Listed Item

Kit, Low Profile, 14Fr, 25cm,Sheath Lock

Insertion Components

The set includes an access guidewire, supplemental dilators and a Luer adaptor. The tapered dilator tip has a hydrophilic coating to aid insertion. The subject sheath is available in 13 and 25 cm lengths, with the dilator hub connecting to the sheath hub.

13manufacturers in China registered for this device type
1catalogue number
6510(k) clearances naming this product code
28recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Beijing (3), Shanghai (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DYB
Manufacturer City Province Registered as Device types
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Tianjin Demax Medical Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 5
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Shanghai INT Medical Instruments Co., Ltd. Shanghai Shanghai Contract manufacturer 10
Lepu Medical Technology (Beijing) Co., Ltd. Beijing Beijing Manufacturer 7
Beijing Target Medical Technologies Inc. Beijing Beijing Contract manufacturer 7
Beijing Demax Medical Technology Co., Ltd. Beijing Beijing Manufacturer 5
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Tianjin Ethylene Oxide Sterilization Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 4
Shanghai Microport EP Medtech Co., Ltd. Shanghai Shanghai Manufacturer 3
Becton Dickinson Medical Devices Co., Ltd. Suzhou Suzhou Jiangsu Contract manufacturer 2
Cardiocycle Medical(Suzhou) Co., Ltd. Suzhou Jiangsu Complaint-file establishment 1

Showing 12 of 13. All 13 manufacturers in China registered for Introducer, Catheter

Record

Regulatory record for Abiomed 14Fr Low Profile Introducer
Listed by Abiomed, Inc., United States
FDA product code DYB
Device type Introducer, Catheter
Device class Class 2
Regulation 21 CFR 870.1340
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K222113
Record published 2024-05-13

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Abiomed 14Fr Low Profile Introducer
Catalogue number Size Status
1000458 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Demax Beijing Demax Medical Technology Co., Ltd. 2,841
Arrow Teleflex Medical LLC 1,036
Prelude IDeal™ Merit Medical Systems, Inc. 294
Fast-Cath™ St. Jude Medical 213
Flexor Cook Incorporated 182
Prelude Ease™ Merit Medical Systems, Inc. 176
Performer Cook Incorporated 174
VSI Teleflex Medical LLC 154
Peel-Away Cook Incorporated 153
OptiSeal™ Greatbatch Medical 127
Brilliant Lepu Medical Technology (Beijing) Co., Ltd. 122
Super Sheath Togo Medikit Co., Ltd. 122

Showing 12 of 439. All products under Introducer, Catheter

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252766 2025-10-08
K241708 2024-08-06
K222113 2022-10-13
K202330 2020-12-07
K201116 2020-06-15
K192769 2019-11-18

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Abiomed 14Fr Low Profile Introducer
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Abiomed, Inc. 510(k) number 2023-05-26 Class II Under Investigation by firm There was one complaint that the sidearm of the device detached during explant of a pump. When the sidearms are subjected to heat, humidity and articulation, a silicone oil contaminant that was unintentionally introduced during manufacturi 37 units

Recalls

17 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2026-06-11 Class I Under Investigation by firm A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are 1,540 units
2026-06-11 Class I Under Investigation by firm A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are 35,430 units
2026-06-11 Class I Under Investigation by firm A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are 1,574 units
2026-06-11 Class I Under Investigation by firm A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are 5,017 units
2026-06-11 Class I Under Investigation by firm A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are 8,382 units
2026-06-11 Class I Under Investigation by firm A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are 87,277 units
2026-06-11 Class I Under Investigation by firm A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are 557 units
2026-06-11 Class I Under Investigation by firm A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are 383 units
2026-06-11 Class I Under Investigation by firm A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are 196 units
2026-06-11 Class I Under Investigation by firm A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are 96 units
2026-06-11 Class I Under Investigation by firm A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are 846 units
2026-06-11 Class I Under Investigation by firm A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are 1,223 units
2026-06-11 Class I Under Investigation by firm A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are 117 units
2026-05-22 Class I Under Investigation by firm Potential for thrombus formation during prolonged use of the introducer. 3 units
2026-05-22 Class I Under Investigation by firm Potential for thrombus formation during prolonged use of the introducer. 17 units
2026-05-22 Class I Under Investigation by firm Potential for thrombus formation during prolonged use of the introducer. 168 units
2026-05-22 Class I Under Investigation by firm Potential for thrombus formation during prolonged use of the introducer. 7 units
2023-11-07 Class II Process control Hole(s) to the outer pouch of the Introducer Kits (both trayed and non-trayed) may compromise the sterile barrier of the Introducer Kits. Non-sterile product exposes patients to the possibility of the introduction of micro-organisms into th 3 single units
2023-11-07 Class II Process control Hole(s) to the outer pouch of the Introducer Kits (both trayed and non-trayed) may compromise the sterile barrier of the Introducer Kits. Non-sterile product exposes patients to the possibility of the introduction of micro-organisms into th 717 single units; 1906 within sets
2023-11-07 Class II Process control Hole(s) to the outer pouch of the Introducer Kits (both trayed and non-trayed) may compromise the sterile barrier of the Introducer Kits. Non-sterile product exposes patients to the possibility of the introduction of micro-organisms into th 1784 single units
2023-11-07 Class II Process control Hole(s) to the outer pouch of the Introducer Kits (both trayed and non-trayed) may compromise the sterile barrier of the Introducer Kits. Non-sterile product exposes patients to the possibility of the introduction of micro-organisms into th
2023-11-07 Class II Process control Hole(s) to the outer pouch of the Introducer Kits (both trayed and non-trayed) may compromise the sterile barrier of the Introducer Kits. Non-sterile product exposes patients to the possibility of the introduction of micro-organisms into th 2551 units within set
2023-11-07 Class II Process control Hole(s) to the outer pouch of the Introducer Kits (both trayed and non-trayed) may compromise the sterile barrier of the Introducer Kits. Non-sterile product exposes patients to the possibility of the introduction of micro-organisms into th 2 units within kit
2023-11-07 Class II Process control Hole(s) to the outer pouch of the Introducer Kits (both trayed and non-trayed) may compromise the sterile barrier of the Introducer Kits. Non-sterile product exposes patients to the possibility of the introduction of micro-organisms into th 1 unit within kit
2023-11-07 Class II Process control Hole(s) to the outer pouch of the Introducer Kits (both trayed and non-trayed) may compromise the sterile barrier of the Introducer Kits. Non-sterile product exposes patients to the possibility of the introduction of micro-organisms into th 4 single units
2023-11-07 Class II Process control Hole(s) to the outer pouch of the Introducer Kits (both trayed and non-trayed) may compromise the sterile barrier of the Introducer Kits. Non-sterile product exposes patients to the possibility of the introduction of micro-organisms into th 193 single units; 1034 units within kits
2023-11-07 Class II Process control Hole(s) to the outer pouch of the Introducer Kits (both trayed and non-trayed) may compromise the sterile barrier of the Introducer Kits. Non-sterile product exposes patients to the possibility of the introduction of micro-organisms into th 84 units within kits

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer