Carto Vizigo

The CARTO VIZIGO 8.5F Bi-Directional Guiding Sheath introduces cardiovascular catheters into the heart, including access to the left heart through the interatrial septum. A rotating handle…

Registry build 21.09.26

The CARTO VIZIGO 8.5F Bi-Directional Guiding Sheath introduces cardiovascular catheters into the heart, including access to the left heart through the interatrial septum. A rotating handle collar bends the flexible tip in either direction to help position the catheter.

Four electrodes along the sheath shaft enable visualization with compatible CARTO 3 electrophysiology navigation systems. A radiopaque tip marker also permits visualization with fluoroscopy.

Listed Item

CARTO VIZIGO Bi-Directional Guiding Sheath

Fluid and Catheter Access

A hemostasis valve limits blood loss during catheter introduction or exchange. The side port has a three-way stopcock for aspiration or infusion, and distal vent holes facilitate aspiration. The sheath family offers small, medium and large curve options.

13manufacturers in China registered for this device type
2catalogue numbers in this listing
3510(k) clearances naming this product code
12recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Beijing (3), Shanghai (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DYB
Manufacturer City Province Registered as Device types
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Tianjin Demax Medical Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 5
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Shanghai INT Medical Instruments Co., Ltd. Shanghai Shanghai Contract manufacturer 10
Lepu Medical Technology (Beijing) Co., Ltd. Beijing Beijing Manufacturer 7
Beijing Target Medical Technologies Inc. Beijing Beijing Contract manufacturer 7
Beijing Demax Medical Technology Co., Ltd. Beijing Beijing Manufacturer 5
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Tianjin Ethylene Oxide Sterilization Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 4
Shanghai Microport EP Medtech Co., Ltd. Shanghai Shanghai Manufacturer 3
Becton Dickinson Medical Devices Co., Ltd. Suzhou Suzhou Jiangsu Contract manufacturer 2
Cardiocycle Medical(Suzhou) Co., Ltd. Suzhou Jiangsu Complaint-file establishment 1

Showing 12 of 13. All 13 manufacturers in China registered for Introducer, Catheter

Record

Regulatory record for Carto Vizigo
Listed by Biosense Webster, Inc., United States
FDA product code DYB
Device type Introducer, Catheter
Device class Class 2
Regulation 21 CFR 870.1340
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K170997
Record published 2026-05-11

Specifications

Specifications
MRI safety MR Unsafe
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Storage Storage environment temperature 41 to 77 °F; Special storage condition: Do not use if package is damaged; Special storage condition: Keep out of direct sunlight; Storage environment temperature 5 to 25 °C; Special storage condition: Keep Dry

Catalogue Numbers

Catalogue numbers for Carto Vizigo
Catalogue number Size Status
D138505 In distribution
D138504 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Demax Beijing Demax Medical Technology Co., Ltd. 2,841
Arrow Teleflex Medical LLC 1,036
Prelude IDeal™ Merit Medical Systems, Inc. 294
Fast-Cath™ St. Jude Medical 213
Flexor Cook Incorporated 182
Prelude Ease™ Merit Medical Systems, Inc. 176
Performer Cook Incorporated 174
VSI Teleflex Medical LLC 154
Peel-Away Cook Incorporated 153
OptiSeal™ Greatbatch Medical 127
Brilliant Lepu Medical Technology (Beijing) Co., Ltd. 122
Super Sheath Togo Medikit Co., Ltd. 122

Showing 12 of 439. All products under Introducer, Catheter

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K231412 2023-07-10
K170997 2017-07-25
K001139 2000-05-10

Recalls Naming This Product

7 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Carto Vizigo
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Biosense Webster, Inc. 510(k) number 2024-02-16 Class II Under Investigation by firm Due to a manufacturing issue, device under process validation phase were inadvertently mixed into the main manufacturing process. 853 units
Biosense Webster, Inc. 510(k) number 2023-02-21 Class II Under Investigation by firm Incorrect labeling; specifically, the product name, lot number and product code on the carton label for Bi-Directional Guiding Sheaths does not match the inner label pouch 277
Biosense Webster, Inc. 510(k) number 2023-02-21 Class II Under Investigation by firm Incorrect labeling; specifically, the product name, lot number and product code on the carton label for Bi-Directional Guiding Sheaths does not match the inner label pouch 316 units
Biosense Webster, Inc. 510(k) number 2022-06-29 Class II Material/Component Contamination Outside packaging for a device indicated for introducing cardiovascular catheters into the heart, sustained water damage, which may have affected the sterile barrier of the product inside. Devices with a compromised sterile barrier could b 98
Biosense Webster, Inc. 510(k) number 2021-02-26 Class II Device Design There is a potential for the hemostatic valve to dislodge while introducing the dilator or device into the sheath. This could result in minor bleeding and/or embolism 71,473 units
Biosense Webster, Inc. 510(k) number 2021-02-26 Class II Device Design There is a potential for the hemostatic valve to dislodge while introducing the dilator or device into the sheath. This could result in minor bleeding and/or embolism
Biosense Webster, Inc. 510(k) number 2021-02-26 Class II Device Design There is a potential for the hemostatic valve to dislodge while introducing the dilator or device into the sheath. This could result in minor bleeding and/or embolism

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2006-11-17 Not classified Other Biosense Webster, Inc. has received a number of complaints regarding the radiopaque tip separating or partially detaching from the PREFACE Sheath during use in the left atrium. 26,173 2009-06-25
2006-11-17 Not classified Other Biosense Webster, Inc. has received a number of complaints regarding the radiopaque tip separating or partially detaching from the PREFACE Sheath during use in the left atrium. 401 2009-06-25
2006-11-17 Not classified Other Biosense Webster, Inc. has received a number of complaints regarding the radiopaque tip separating or partially detaching from the PREFACE Sheath during use in the left atrium. 182 2009-06-25
2006-11-17 Not classified Other Biosense Webster, Inc. has received a number of complaints regarding the radiopaque tip separating or partially detaching from the PREFACE Sheath during use in the left atrium. 4565 2009-06-25
2006-11-17 Not classified Other Biosense Webster, Inc. has received a number of complaints regarding the radiopaque tip separating or partially detaching from the PREFACE Sheath during use in the left atrium. 996 2009-06-25

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer