Introducer, Catheter

Intrdcr 206211 10PK 6F 11CM Inpt Shth OB

Registry build 21.09.26
13manufacturers in China registered for this device type
79catalogue numbers in this listing
3510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Beijing (3), Shanghai (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DYB
Manufacturer City Province Registered as Device types
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Tianjin Demax Medical Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 5
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Shanghai INT Medical Instruments Co., Ltd. Shanghai Shanghai Contract manufacturer 10
Lepu Medical Technology (Beijing) Co., Ltd. Beijing Beijing Manufacturer 7
Beijing Target Medical Technologies Inc. Beijing Beijing Contract manufacturer 7
Beijing Demax Medical Technology Co., Ltd. Beijing Beijing Manufacturer 5
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Tianjin Ethylene Oxide Sterilization Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 4
Shanghai Microport EP Medtech Co., Ltd. Shanghai Shanghai Manufacturer 3
Becton Dickinson Medical Devices Co., Ltd. Suzhou Suzhou Jiangsu Contract manufacturer 2
Cardiocycle Medical(Suzhou) Co., Ltd. Suzhou Jiangsu Complaint-file establishment 1

Showing 12 of 13. All 13 manufacturers in China registered for Introducer, Catheter

Record

Regulatory record for Introducer, Catheter
Listed by Medtronic, Inc., United States
FDA product code DYB
Device type Introducer, Catheter
Device class Class 2
Regulation 21 CFR 870.1340
Establishment Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K132617
Record published 2017-02-02
Record revised 2024-03-20 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number
Storage Storage environment temperature up to 40 °C
Packaging Pack of 5, pack of 10
Sizes Catheter gauge 5 to 9 Fr; length 11 to 23 cm; outer diameter 0.81 to 0.97 mm
Distribution end date 2024-12-13

Catalogue Numbers

Catalogue numbers for Introducer, Catheter
Catalogue number Size Status
206211 Length 11.0 cm In distribution
6211-S5 Introducer inner diameter 11 French In distribution
6208-S1 Introducer inner diameter 8 French In distribution
6211-S1 Introducer inner diameter 11 French In distribution
207211 Length 11.0 cm In distribution
6210-S1 Introducer inner diameter 10.5 French In distribution
040044A Length 11.0 cm In distribution
6211-S1 Introducer inner diameter 3.7 mm (11 French) In distribution
6210-S5 Introducer inner diameter 10.5 French In distribution
6212-S1 Introducer inner diameter 12 French In distribution
6214-S1 Introducer inner diameter 14 French In distribution
6214-S1 Introducer inner diameter 14 French In distribution
6207-S1 Introducer inner diameter 2.3 mm (7 French) In distribution
6210-S5 Introducer inner diameter 10.5 French In distribution
6207-S5 Introducer inner diameter 2.3 mm (7 French) In distribution
6212S5 Introducer inner diameter 12 French In distribution
6209-S5 Introducer inner diameter 9 French In distribution
673311 Outer Diameter 0.97 mm In distribution
6210-S1 Introducer inner diameter 10.5 French In distribution
6214-S1 Introducer inner diameter 4.7 mm (14 French) In distribution
205211A Length 11.0 cm In distribution
6209-S5 Introducer inner diameter 9 French In distribution
6209-S1 Introducer inner diameter 9 French In distribution
6214-S5 Introducer inner diameter 14 French In distribution
6207-S5 Introducer inner diameter 7 French In distribution
6211-S5 Introducer inner diameter 3.7 mm (11 French) In distribution
6209-S1 Introducer inner diameter 3.0 mm (9 French) In distribution
205211 Catheter Gauge 5.0 Fr In distribution
6207-S5 Introducer inner diameter 7 French In distribution
6209-S1 Introducer inner diameter 9 French In distribution
6210-S5 Introducer inner diameter 3.5 mm (10.5 French) In distribution
6211-S1 Introducer inner diameter 11 French In distribution
653311 Outer Diameter 0.97 mm In distribution
6208-S5 Introducer inner diameter 2.7 mm (8 French) In distribution
6211-S5 Introducer inner diameter 11 French In distribution
6209-S5 Introducer inner diameter 3.0 mm (9 French) In distribution
6210-S1 Introducer inner diameter 3.5 mm (10.5 French) In distribution
040037A Length 11.0 cm In distribution
6214-S5 Introducer inner diameter 4.7 mm (14 French) In distribution
6208-S5 Introducer inner diameter 8 French In distribution
040049A Outer Diameter 0.97 mm In distribution
207211A Length 11.0 cm In distribution
6212-S5 Introducer inner diameter 12 French In distribution
693311 Length 11.0 cm In distribution
6212-S1 Introducer inner diameter 12 French In distribution
663311 Length 11.0 cm In distribution
6208-S1 Introducer inner diameter 2.7 mm (8 French) In distribution
6214-S5 Introducer inner diameter 14 French In distribution
6208-S1 Introducer inner diameter 8 French In distribution
6207-S1 Introducer inner diameter 7 French In distribution
040042A Catheter Gauge 6.0 Fr In distribution
206211A Length 11.0 cm In distribution
6208-S5 Introducer inner diameter 8 French In distribution
6207-S1 Introducer inner diameter 7 French In distribution
6209-D1 Introducer inner diameter 9 French Withdrawn
6207S1S Introducer inner diameter 7 French Withdrawn
6207-D1 Introducer inner diameter 7 French Withdrawn
6209S5S Introducer inner diameter 9 French Withdrawn
6208S5S Introducer inner diameter 8 French Withdrawn
6207D1S Introducer inner diameter 7 French Withdrawn
6210S5S Introducer inner diameter 10.5 French Withdrawn
207223 Catheter Gauge 7.0 Fr Withdrawn
683311 Length 11.0 cm Withdrawn
EP008591 Sheath length 60cm Withdrawn
208223 Catheter Gauge 8.0 Fr Withdrawn
6211-D1 Introducer inner diameter 11 French Withdrawn
6207S5S Introducer inner diameter 7 French Withdrawn
206223 Catheter Gauge 6.0 Fr Withdrawn
040047A Length 11.0 cm Withdrawn
683323 Outer Diameter 0.97 mm Withdrawn
209211 Length 11.0 cm Withdrawn
6211S5S Introducer inner diameter 11 French Withdrawn
6210-D1 Introducer inner diameter 10.5 French Withdrawn
6208-D1 Introducer inner diameter 8 French Withdrawn
008591 Outer Diameter 0.81 mm Withdrawn
6209S1S Introducer inner diameter 9 French Withdrawn
693323 Outer Diameter 0.97 mm Withdrawn
673323 Length 23.0 cm Withdrawn
208211 Catheter Gauge 8.0 Fr Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Demax Beijing Demax Medical Technology Co., Ltd. 2,841
Arrow Teleflex Medical LLC 1,036
Prelude IDeal™ Merit Medical Systems, Inc. 294
Fast-Cath™ St. Jude Medical 213
Flexor Cook Incorporated 182
Prelude Ease™ Merit Medical Systems, Inc. 176
Performer Cook Incorporated 174
VSI Teleflex Medical LLC 154
Peel-Away Cook Incorporated 153
OptiSeal™ Greatbatch Medical 127
Brilliant Lepu Medical Technology (Beijing) Co., Ltd. 122
Super Sheath Togo Medikit Co., Ltd. 122

Showing 12 of 439. All products under Introducer, Catheter

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K152054 2015-08-07
K132617 2014-04-30
K132030 2013-09-27

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Introducer, Catheter
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Medtronic, Inc. 510(k) number 2013-07-08 Class II Packaging change control Medtronic identified a specific labeling issue for specific lots of Mullins Transseptal Catheter Introducer Sheath, model 008551, in which packages labeled as Mullins 7F (French) may actually contain an 8F(French) dilator. Medtronic is req 269 2014-03-06
Medtronic Vascular 510(k) number 2008-10-07 Not classified Nonconforming Material/Component Failure to insert the guidewire through the 18 gauge introducer needle 1,830 2011-06-07
Medtronic Vascular 510(k) number 2008-10-07 Not classified Nonconforming Material/Component Failure to insert the guidewire through the 18 gauge introducer needle 2,585 units 2011-06-07
Medtronic Vascular 510(k) number 2008-10-07 Not classified Nonconforming Material/Component Failure to insert the guidewire through the 18 gauge introducer needle 1,805 units 2011-06-07
Medtronic Vascular 510(k) number 2008-10-07 Not classified Nonconforming Material/Component Failure to insert the guidewire through the 18 gauge introducer needle 335 units 2011-06-07

Recalls

1 of these is Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2015-02-23 Class I Nonconforming Material/Component Clinicians observed debris, appearing to originate from the hemostasis valve on the proximal end of the Steerable Sheath, outside of the patients bodies. 151 (4 US, 147 OUS) 2015-10-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer