Introducer Kit for Impella®

Hemostatic Peel Away Introducer System with Infusion Sideport, 14F 13 cm and 25 cm

Registry build 21.09.26
13manufacturers in China registered for this device type
11catalogue numbers in this listing
14510(k) clearances naming this product code
37recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Beijing (3), Shanghai (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DYB
Manufacturer City Province Registered as Device types
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Tianjin Demax Medical Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 5
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Shanghai INT Medical Instruments Co., Ltd. Shanghai Shanghai Contract manufacturer 10
Lepu Medical Technology (Beijing) Co., Ltd. Beijing Beijing Manufacturer 7
Beijing Target Medical Technologies Inc. Beijing Beijing Contract manufacturer 7
Beijing Demax Medical Technology Co., Ltd. Beijing Beijing Manufacturer 5
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Tianjin Ethylene Oxide Sterilization Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 4
Shanghai Microport EP Medtech Co., Ltd. Shanghai Shanghai Manufacturer 3
Becton Dickinson Medical Devices Co., Ltd. Suzhou Suzhou Jiangsu Contract manufacturer 2
Cardiocycle Medical(Suzhou) Co., Ltd. Suzhou Jiangsu Complaint-file establishment 1

Showing 12 of 13. All 13 manufacturers in China registered for Introducer, Catheter

Record

Regulatory record for Introducer Kit for Impella®
Listed by Oscor Inc., United States
FDA product code DYB
Device type Introducer, Catheter
Device class Class 2
Regulation 21 CFR 870.1340
Establishment Contract manufacturer, Contract steriliser, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K122084
Record published 2019-09-24
Record revised 2026-06-11 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date, manufacturing date
Storage Storage environment temperature 5 to 30 °C
Sizes Length 6 to 30 cm
Distribution end date 2019-07-29

Catalogue Numbers

Catalogue numbers for Introducer Kit for Impella®
Catalogue number Size Status
0052-3025 Sheath Length 13 cm In distribution
0052-3014 Length 13 cm In distribution
0052-3000 Length 13 cm In distribution
0052-3001 Length 30 cm In distribution
0052-3006 Length 6 cm In distribution
0052-3015 Length 25 cm In distribution
0052-3021 Length 30 cm In distribution
0052-3025 Sheath Length 13 cm Withdrawn
0052-3014 Length 13 cm Withdrawn
0052-3021 Length 30 cm Withdrawn
0052-3015 Length 25 cm Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Demax Beijing Demax Medical Technology Co., Ltd. 2,841
Arrow Teleflex Medical LLC 1,036
Prelude IDeal™ Merit Medical Systems, Inc. 294
Fast-Cath™ St. Jude Medical 213
Flexor Cook Incorporated 182
Prelude Ease™ Merit Medical Systems, Inc. 176
Performer Cook Incorporated 174
VSI Teleflex Medical LLC 154
Peel-Away Cook Incorporated 153
OptiSeal™ Greatbatch Medical 127
Brilliant Lepu Medical Technology (Beijing) Co., Ltd. 122
Super Sheath Togo Medikit Co., Ltd. 122

Showing 12 of 439. All products under Introducer, Catheter

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K210627 2021-06-03
K151951 2015-09-22
K140917 2014-07-09
K140406 2014-04-17
K130633 2014-02-13
K122958 2012-12-13
K122960 2012-12-13
K122084 2012-08-29
K120459 2012-06-29
K101497 2010-10-20
K090114 2009-06-04
K073100 2007-11-30
K890277 1989-03-10
K831751 1983-10-20

Recalls Naming This Product

6 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.

Recalls naming the identifiers of Introducer Kit for Impella®
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Oscor Inc. 510(k) number 2026-06-10 Class I Device Design Due to manufacturing issues, there is a potential for the 14Fr and 23Fr introducer sheaths to leak from the sidearm, under the sheath cap, and along the hub score lines in the hub region. 355 units
Oscor Inc. 510(k) number 2026-06-10 Class I Device Design Due to manufacturing issues, there is a potential for the 14Fr and 23Fr introducer sheaths to leak from the sidearm, under the sheath cap, and along the hub score lines in the hub region. 1332 units
Oscor Inc. 510(k) number 2026-06-10 Class I Device Design Due to manufacturing issues, there is a potential for the 14Fr and 23Fr introducer sheaths to leak from the sidearm, under the sheath cap, and along the hub score lines in the hub region. 32,934 units
Abiomed, Inc. UDI-DI 2023-11-07 Class II Process control Hole(s) to the outer pouch of the Introducer Kits (both trayed and non-trayed) may compromise the sterile barrier of the Introducer Kits. Non-sterile product exposes patients to the possibility of the introduction of micro-organisms into th 717 single units; 1906 within sets
Abiomed, Inc. UDI-DI 2023-11-07 Class II Process control Hole(s) to the outer pouch of the Introducer Kits (both trayed and non-trayed) may compromise the sterile barrier of the Introducer Kits. Non-sterile product exposes patients to the possibility of the introduction of micro-organisms into th 193 single units; 1034 units within kits
AngioDynamics, Inc. 510(k) number 2021-02-22 Class II Under Investigation by firm AngioDynamics, Inc. is recalling a specific batch of AngioDynamics Implantable Infusion Port kits and Valved introducers that may have potential for compromised sterility of the device. Only the specific product/lot of the kit identified be 337 units, (14 boxes of 5, 267 units each kit) 2022-07-19

Recalls

32 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2021-12-22 Class II Process control There is potential for separation between the threaded hub and threaded cap at the proximal end of the device. 549 units
2021-03-10 Class II Under Investigation by firm Potential for open seal on sterile product 500 devices 2023-08-08
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 34 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 21 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 61 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 124 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 8 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 255 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 215 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 11 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 26 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 1,729 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 87 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 991 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 70 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 59 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 45 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 16 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 21 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 991 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 76 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 22 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 186 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 55 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 74 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 156 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 566 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 20 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 30 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 1,269 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 33 2019-07-26
2016-10-05 Class II Nonconforming Material/Component Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use. 110 2019-07-26
2008-07-03 Not classified Process design Difficulty breaking the sheath hub and subsequently to peel the sheath off for Introducer Set, Adelante size 7F. 396 2008-12-09
2005-09-13 Not classified Other Sheath size is larger than dilator size causing insertion difficulties. 6985 2012-07-08

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer