Micro-Stick Setmicro-Stick SET

4F (1.0MM ID) X 9CM4F (1.0MM ID) Regular Micro-Stick® Introducer SET Withintroducer SE Stainless Steel Guidewirestainle With Radiopaque Tipwith Radiopaq

Registry build 21.09.26
13manufacturers in China registered for this device type
31catalogue numbers in this listing
2510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Jiangsu (5), Beijing (3), Shanghai (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DYB
Manufacturer City Province Registered as Device types
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Tianjin Demax Medical Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 5
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Shanghai INT Medical Instruments Co., Ltd. Shanghai Shanghai Contract manufacturer 10
Lepu Medical Technology (Beijing) Co., Ltd. Beijing Beijing Manufacturer 7
Beijing Target Medical Technologies Inc. Beijing Beijing Contract manufacturer 7
Beijing Demax Medical Technology Co., Ltd. Beijing Beijing Manufacturer 5
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Tianjin Ethylene Oxide Sterilization Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 4
Shanghai Microport EP Medtech Co., Ltd. Shanghai Shanghai Manufacturer 3
Becton Dickinson Medical Devices Co., Ltd. Suzhou Suzhou Jiangsu Contract manufacturer 2
Cardiocycle Medical(Suzhou) Co., Ltd. Suzhou Jiangsu Complaint-file establishment 1

Showing 12 of 13. All 13 manufacturers in China registered for Introducer, Catheter

Record

Regulatory record for Micro-Stick Setmicro-Stick SET
Listed by Medical Components Inc, United States
FDA product code DYB
Device type Introducer, Catheter
Device class Class 2
Regulation 21 CFR 870.1340
Establishment Contract manufacturer, Reprocessor, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2019-06-05
Record revised 2022-07-15 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Packaging Inner box of 10, box of 4, box of 10, box
Distribution end date 2025-03-03

Catalogue Numbers

Catalogue numbers for Micro-Stick Setmicro-Stick SET
Catalogue number Size Status
DMR190411 In distribution
DMR190521 In distribution
DMR190422 In distribution
DMR190522 In distribution
MR190421 In distribution
DMR190511 In distribution
DMR190512 In distribution
DMR190421 In distribution
DMR190503 In distribution
DMR190412 In distribution
MR192422 Withdrawn
JT130400000 Withdrawn
MR192421 Withdrawn
MR190412 Withdrawn
MR190404 Withdrawn
RMS19421 Withdrawn
MR192511 Withdrawn
MR190512 Withdrawn
AAC19601 Withdrawn
MR192512 Withdrawn
MR192411 Withdrawn
RMS19411 Withdrawn
MR190503 Withdrawn
MR192522 Withdrawn
MR193521 Withdrawn
JT120400000 Withdrawn
JT120500000 Withdrawn
MR190422 Withdrawn
JT130500000 Withdrawn
MR190411 Withdrawn
MR192521 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Demax Beijing Demax Medical Technology Co., Ltd. 2,841
Arrow Teleflex Medical LLC 1,036
Prelude IDeal™ Merit Medical Systems, Inc. 294
Fast-Cath™ St. Jude Medical 213
Flexor Cook Incorporated 182
Prelude Ease™ Merit Medical Systems, Inc. 176
Performer Cook Incorporated 174
VSI Teleflex Medical LLC 154
Peel-Away Cook Incorporated 153
OptiSeal™ Greatbatch Medical 127
Brilliant Lepu Medical Technology (Beijing) Co., Ltd. 122
Super Sheath Togo Medikit Co., Ltd. 122

Showing 12 of 439. All products under Introducer, Catheter

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K130687 2013-08-15
K124046 2013-06-03

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-05-05 Class II Labeling mix-ups This recall has been initiated due to the product labeled with the incorrect expiration date. VS203 Lot# MBZX140 (100 units); VS303 Lot # MBZL450 (60 unit 2017-06-16

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer