Mullins Transseptal

Introducer 008551 Mullin Tran Cath 7F AD

Registry build 21.09.26
13manufacturers in China registered for this device type
5catalogue numbers in this listing
3510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Beijing (3), Shanghai (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DYB
Manufacturer City Province Registered as Device types
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Tianjin Demax Medical Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 5
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Shanghai INT Medical Instruments Co., Ltd. Shanghai Shanghai Contract manufacturer 10
Lepu Medical Technology (Beijing) Co., Ltd. Beijing Beijing Manufacturer 7
Beijing Target Medical Technologies Inc. Beijing Beijing Contract manufacturer 7
Beijing Demax Medical Technology Co., Ltd. Beijing Beijing Manufacturer 5
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Tianjin Ethylene Oxide Sterilization Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 4
Shanghai Microport EP Medtech Co., Ltd. Shanghai Shanghai Manufacturer 3
Becton Dickinson Medical Devices Co., Ltd. Suzhou Suzhou Jiangsu Contract manufacturer 2
Cardiocycle Medical(Suzhou) Co., Ltd. Suzhou Jiangsu Complaint-file establishment 1

Showing 12 of 13. All 13 manufacturers in China registered for Introducer, Catheter

Record

Regulatory record for Mullins Transseptal
Listed by Medtronic, Inc., United States
FDA product code DYB
Device type Introducer, Catheter
Device class Class 2
Regulation 21 CFR 870.1340
Establishment Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K791963
Record published 2017-02-02
Record revised 2024-11-19 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Sizes Outer diameter 0.64 to 0.81 mm; catheter gauge 6 to 8 Fr
Distribution end date 2024-11-14

Catalogue Numbers

Catalogue numbers for Mullins Transseptal
Catalogue number Size Status
008531 Outer Diameter 0.64 mm Withdrawn
008550 Outer Diameter 0.81 mm Withdrawn
008551 60 CM Sheath Length Withdrawn
008532 Outer Diameter 0.64 mm Withdrawn
008552 60 CM Sheath Length Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Demax Beijing Demax Medical Technology Co., Ltd. 2,841
Arrow Teleflex Medical LLC 1,036
Prelude IDeal™ Merit Medical Systems, Inc. 294
Fast-Cath™ St. Jude Medical 213
Flexor Cook Incorporated 182
Prelude Ease™ Merit Medical Systems, Inc. 176
Performer Cook Incorporated 174
VSI Teleflex Medical LLC 154
Peel-Away Cook Incorporated 153
OptiSeal™ Greatbatch Medical 127
Brilliant Lepu Medical Technology (Beijing) Co., Ltd. 122
Super Sheath Togo Medikit Co., Ltd. 122

Showing 12 of 439. All products under Introducer, Catheter

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K152054 2015-08-07
K132617 2014-04-30
K132030 2013-09-27

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Mullins Transseptal
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Medtronic, Inc. 510(k) number 2013-07-08 Class II Packaging change control Medtronic identified a specific labeling issue for specific lots of Mullins Transseptal Catheter Introducer Sheath, model 008551, in which packages labeled as Mullins 7F (French) may actually contain an 8F(French) dilator. Medtronic is req 269 2014-03-06

Recalls

1 of these is Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2015-02-23 Class I Nonconforming Material/Component Clinicians observed debris, appearing to originate from the hemostasis valve on the proximal end of the Steerable Sheath, outside of the patients bodies. 151 (4 US, 147 OUS) 2015-10-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer