Powerwand™ XL-REC
The POWERWAND XL-REC Introducer with Extended Dwell Catheter. *Power Injectable. *ZERO-EDGE transitions. *Radiopaque
Who Else Makes It
Concentrated in Jiangsu (5), Beijing (3), Shanghai (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Mehow Innovative (Huizhou) Ltd. | Huizhou | Guangdong | Contract manufacturer | 11 |
| Tianjin Demax Medical Technology Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 5 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Shanghai INT Medical Instruments Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Lepu Medical Technology (Beijing) Co., Ltd. | Beijing | Beijing | Manufacturer | 7 |
| Beijing Target Medical Technologies Inc. | Beijing | Beijing | Contract manufacturer | 7 |
| Beijing Demax Medical Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 5 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Tianjin Ethylene Oxide Sterilization Technology Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 4 |
| Shanghai Microport EP Medtech Co., Ltd. | Shanghai | Shanghai | Manufacturer | 3 |
| Becton Dickinson Medical Devices Co., Ltd. Suzhou | Suzhou | Jiangsu | Contract manufacturer | 2 |
| Cardiocycle Medical(Suzhou) Co., Ltd. | Suzhou | Jiangsu | Complaint-file establishment | 1 |
Showing 12 of 13. All 13 manufacturers in China registered for Introducer, Catheter
Record
| Listed by | ICU Medical, Inc, United States |
|---|---|
| FDA product code | DYB |
| Device type | Introducer, Catheter |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1340 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K131300 |
| Record published | 2017-05-30 |
| Record revised | 2025-03-18 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Storage | Handling environment temperature 32 to 104 °F; Special storage condition: Protect from direct contact with sun, water and humidity |
| Packaging | Overpack of 12, shipper box of 10 |
| Sizes | Catheter gauge 4 Fr; length 6 cm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 4Fr x 6cm | Catheter Gauge 4 Fr | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Demax | Beijing Demax Medical Technology Co., Ltd. | 2,841 |
| Arrow | Teleflex Medical LLC | 1,036 |
| Prelude IDeal™ | Merit Medical Systems, Inc. | 294 |
| Fast-Cath™ | St. Jude Medical | 213 |
| Flexor | Cook Incorporated | 182 |
| Prelude Ease™ | Merit Medical Systems, Inc. | 176 |
| Performer | Cook Incorporated | 174 |
| VSI | Teleflex Medical LLC | 154 |
| Peel-Away | Cook Incorporated | 153 |
| OptiSeal™ | Greatbatch Medical | 127 |
| Brilliant | Lepu Medical Technology (Beijing) Co., Ltd. | 122 |
| Super Sheath | Togo Medikit Co., Ltd. | 122 |
Showing 12 of 439. All products under Introducer, Catheter
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Access Scientific, Inc. | 510(k) number | 2013-08-16 | Class II | Labeling Change Control | Access Scientific is recalling the POWERWAND Saftey Introducer with Extended Dwell Catheter because it is mislabeled. | 160 units | 2013-09-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.