Truwave, Vamp Plus
19 catalogue numbers from PXVP1089, listed by Edwards Lifesciences Technology Sarl, United States, under Catheter, Continuous Flush. 5 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (1), Guangdong (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shanghai Wallaby Medical Technologies Co., Inc. | Shanghai | Shanghai | Contract manufacturer | 5 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Suzhou Hengrui Hongyuan Medical Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
| Vascupatent Medical (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 1 |
Record
| Listed by | Edwards Lifesciences Technology Sarl, United States |
|---|---|
| FDA product code | KRA |
| Device type | Catheter, Continuous Flush |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1210 |
| Establishment | Contract manufacturer, Specification developer, Manufacturer |
| 510(k) | K142749 |
| Record published | 2016-09-03 |
| Record revised | 2018-12-05 (version 5) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: STORE IN A COOL, DRY PLACE. |
| Packaging | Shipper of 10, shipper of 5 |
| Sizes | Total volume 3 ml |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| PXVP1089 | Total Volume: 3 cc, Length: 67 Inch (170 Centimeter) | In distribution |
| T490007A | TOTAL VOLUME: 3 MILLILITER, LENGTH: 67 INCH (170 CENTIMETER) | In distribution |
| PXVPL0113 | Volume 3 cc; Length 84 inches | In distribution |
| PXVPL0097 | 85 in (216 cm) | In distribution |
| PXVP0765 | Total Volume: 3 cc, Length: 76 Inch (193 Centimeter) | In distribution |
| PXVP1072 | Total Volume: 3 cc, Length: 87 Inch (221 Centimeter) | In distribution |
| T001691M | Volume 3 cc, Length 215 cm | In distribution |
| PXVP2284 | TOTAL VOLUME: 3 CC, LENGTH: 84 INCH (210 CENTIMETER) | In distribution |
| T430023M | 3 CC Length 215 cm | In distribution |
| PXVP0778 | TOTAL VOLUME: 3 CC, LENGTH: 90 INCH (230 CENTIMETER) | In distribution |
| PXVP0686 | Total Volume 3 ml | In distribution |
| PXVP1071 | Total Volume: 3 cc, Length: 87 Inch (221 Centimeter) | In distribution |
| PXVP1073 | TOTAL VOLUME: 3 CC, LENGTH: 87 INCH (221 CENTIMETER) | In distribution |
| PXVP0550 | Total Volume: 3 cc, Length: 91 Inch (231 Centimeter) | In distribution |
| PXVP1087 | Total Volume 3 ml | In distribution |
| PXVP0812 | Total Volume 3 ml | In distribution |
| PXVPL0030 | Total Volume: 3 cc, Length: 86 Inch (218 Centimeter) | In distribution |
| PXVPL0111 | Volume 3 cc; Length 84 inches | In distribution |
| PXVP23X3AT3 | Total Volume 3 ml | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Fountain® | Merit Medical Systems, Inc. | 154 |
| PulseSpray | AngioDynamics, Inc. | 149 |
| Merit Maestro® | Merit Medical Systems, Inc. | 143 |
| Phenom™ Catheter | Cathera, Inc. | 103 |
| UniFuse | AngioDynamics, Inc. | 84 |
| CXI | Cook Incorporated | 48 |
| Uni-Fuse+ | AngioDynamics, Inc. | 32 |
| Prowler | Medos International Sàrl | 27 |
| Truwave, Vamp | Edwards Lifesciences Technology Sarl | 26 |
| ICU Medical | ICU Medical, Inc | 21 |
| Cantata | Cook Incorporated | 20 |
| Deltran | Utah Medical Products, Inc. | 19 |
Showing 12 of 149. All products under Catheter, Continuous Flush
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K181684 | 2018-11-08 |
| K180275 | 2018-10-24 |
| K173586 | 2018-04-05 |
| K161962 | 2016-11-28 |
Recalls Naming This Product
11 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Edwards Lifesciences Technology Sarl | UDI-DI | 2023-10-04 | Class II | Device Design | Their is the potential for flushing difficulties during setup of the pressure monitoring kit with pressure transducer. | 168,014 units | |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2021-05-26 | Class II | Under Investigation by firm | There is a potential that the pressure tubing may detach from the blood sampling system | 460 units | 2023-12-14 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2021-05-26 | Class II | Under Investigation by firm | There is a potential that the pressure tubing may detach from the blood sampling system | 700 units | 2023-12-14 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2021-05-26 | Class II | Under Investigation by firm | There is a potential that the pressure tubing may detach from the blood sampling system | 290 units | 2023-12-14 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2021-05-26 | Class II | Under Investigation by firm | There is a potential that the pressure tubing may detach from the blood sampling system | 2,000 units | 2023-12-14 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2021-05-26 | Class II | Under Investigation by firm | There is a potential that the pressure tubing may detach from the blood sampling system | 1,679 units | 2023-12-14 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2021-05-26 | Class II | Under Investigation by firm | There is a potential that the pressure tubing may detach from the blood sampling system | 990 units | 2023-12-14 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2021-05-26 | Class II | Under Investigation by firm | There is a potential that the pressure tubing may detach from the blood sampling system | 50 units | 2023-12-14 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2021-05-26 | Class II | Under Investigation by firm | There is a potential that the pressure tubing may detach from the blood sampling system | 90 units | 2023-12-14 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2015-07-31 | Class II | Device Design | Flow restriction issues in a trifurcated IV set included in the pressure transducer kits. A restriction of the flow of IV fluid would result in either an inability to prime the system before use or difficulty in flushing the line after a bl | 13,077 (U.S.) and 12,306 (International) | 2016-07-08 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2013-01-30 | Class II | Process change control | The device is being recalled because the firm has received multiple complaints related to incorrect assembly that may result in dilution of blood samples. | 30,467 | 2016-03-10 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2009-02-09 | Not classified | Software design | Cardiac output measurements were unavailable and the following message is displayed in the Vigilance monitor: “Fault. CCO Catheter Verification. Use Bolus Mode”. | 2,728 units | 2011-04-11 |
| 2009-02-09 | Not classified | Software design | Cardiac output measurements were unavailable and the following message is displayed in the Vigilance monitor: “Fault. CCO Catheter Verification. Use Bolus Mode”. | 107 units | 2011-04-11 |
| 2009-02-09 | Not classified | Software design | Cardiac output measurements were unavailable and the following message is displayed in the Vigilance monitor: “Fault. CCO Catheter Verification. Use Bolus Mode”. | 35 units | 2011-04-11 |