Conquest® 40

Conquest® 40 PTA Dilatation Catheter 10 mm x 80 mm, 75 cm catheter

Registry build 21.09.26
5manufacturers in China registered for this device type
29catalogue numbers in this listing
6510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Jiangsu (3), Guangdong (2).

Chinese manufacturers registered for FDA product code LIT
Manufacturer City Province Registered as Device types
OrbusNeich Medical (Shenzhen) Co., Ltd. Shenzhen Guangdong Complaint-file establishment 5
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Brosmed Medical Co., Ltd. Dongguan Guangdong Contract manufacturer 4
Kossel Medtech (Suzhou) Co., Ltd. Suzhou Jiangsu Manufacturer 4
DK Medical Technology Co., Ltd. Suzhou Jiangsu Manufacturer 3

Record

Regulatory record for Conquest® 40
Listed by Bard Peripheral Vascular, Inc., United States
FDA product code LIT
Device type Catheter, Angioplasty, Peripheral, Transluminal
Device class Class 2
Regulation 21 CFR 870.1250
Establishment Specification developer, Complaint-file establishment, Manufacturer
Record published 2016-08-19
Record revised 2024-04-17 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Distribution end date 2022-12-02

Catalogue Numbers

Catalogue numbers for Conquest® 40
Catalogue number Size Status
CQF75108 Balloon Length, 80 Millimeter In distribution
CQF5094 Balloon Length, 40 Millimeter In distribution
CQF50810 Balloon Length, 100 Millimeter In distribution
CQF7583 Balloon Diameter, 8 Millimeter In distribution
CQF75102 Catheter Shaft Length, 75 Centimeter In distribution
CQF75104 Balloon Length, 40 Millimeter In distribution
CQF7588 Balloon Diameter, 8 Millimeter In distribution
CQF50610 Catheter Shaft Length, 50 Centimeter In distribution
CQF75610 Balloon Length, 100 Millimeter In distribution
CQF5068 Catheter Shaft Length, 50 Centimeter In distribution
CQF7594 Catheter Shaft Length, 75 Centimeter In distribution
CQF5062 Balloon Diameter, 6 Millimeter In distribution
CQF5078 Catheter Shaft Length, 50 Centimeter In distribution
CQF5092 Balloon Length, 20 Millimeter In distribution
CQF5084 Balloon Diameter, 8 Millimeter In distribution
CQF5042 Balloon Length, 20 Millimeter In distribution
CQF5074 Balloon Length, 40 Millimeter In distribution
CQF5083 Balloon Length, 30 Millimeter In distribution
CQF7558 Balloon Length, 80 Millimeter In distribution
CQF7582 Balloon Length, 20 Millimeter In distribution
CQF50510 Balloon Diameter, 5 Millimeter In distribution
CQF5082 Balloon Length, 20 Millimeter In distribution
CQF5048 Balloon Length, 80 Millimeter In distribution
CQF7578 Balloon Length, 80 Millimeter In distribution
CQF7548 Catheter Shaft Length, 75 Centimeter In distribution
CQF5088 Balloon Diameter, 8 Millimeter In distribution
CQF5046 Balloon Length, 60 Millimeter Withdrawn
CQF5076 Balloon Diameter, 7 Millimeter Withdrawn
CQF5086 Catheter Shaft Length, 50 Centimeter Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Parafleet SC 018 PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 1,460
Jade Plus PTA Balloon Dilatation Catheter / Jade Plus 18 OTW OrbusNeich Medical (Shenzhen) Co., Ltd. 832
Jade PTA Balloon Dilatation Catheter OrbusNeich Medical (Shenzhen) Co., Ltd. 667
Parafleet SC 014 PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 572
Minerva PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 504
Advocate Arravasc, Ltd. 441
Ultraverse® 035 PTA Dilatation Catheter Bard Peripheral Vascular, Inc. 361
Polux PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 359
Advance Cook Incorporated 355
Pacific™ Plus Medtronic, Inc. 347
EverCross™ ev3, Inc. 316
Achilles NC PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 297

Showing 12 of 167. All products under Catheter, Angioplasty, Peripheral, Transluminal

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K192318 2019-10-03
K142261 2014-09-24
K131199 2013-05-30
K120971 2012-04-19
K120722 2012-04-19
K120660 2012-03-15

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-08-14 Class II Labeling mix-ups The catheter packaging incorrectly listed the balloon size as 8mm X 20mm instead of the intended size 8mm X 40mm. If undetected, the user will advance the longer than expected balloon to the lesion. The potential exists that upon inflation 286 Units 2021-02-26

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer