Pacific Xtreme

Pacific Xtreme is an over-the-wire balloon catheter for dilating narrowing in the femoral, popliteal and infrapopliteal arteries. The catheter has a proximal hub, dual-lumen coaxial shaft…

Registry build 21.09.26

Pacific Xtreme is an over-the-wire balloon catheter for dilating narrowing in the femoral, popliteal and infrapopliteal arteries. The catheter has a proximal hub, dual-lumen coaxial shaft and distal dilatation balloon.

A hydrophilic coating covers the catheter. It accepts guidewires up to 0.018 inch and is compatible with 4F or 5F introducer sheaths, depending on balloon diameter and length.

Listed Item

Cath PCU040300090 PCU US 04.00L300UL0900

Length Options

Usable catheter lengths are 90 and 130 cm. The described peripheral artery indications apply to balloon lengths of 150, 200, 250 and 300 mm. The device is designed for limited contact with circulating blood during the procedure.

5manufacturers in China registered for this device type
55catalogue numbers in this listing
3510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Jiangsu (3), Guangdong (2).

Chinese manufacturers registered for FDA product code LIT
Manufacturer City Province Registered as Device types
OrbusNeich Medical (Shenzhen) Co., Ltd. Shenzhen Guangdong Complaint-file establishment 5
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Brosmed Medical Co., Ltd. Dongguan Guangdong Contract manufacturer 4
Kossel Medtech (Suzhou) Co., Ltd. Suzhou Jiangsu Manufacturer 4
DK Medical Technology Co., Ltd. Suzhou Jiangsu Manufacturer 3

Record

Regulatory record for Pacific Xtreme
Listed by Medtronic, Inc., United States
FDA product code LIT
Device type Catheter, Angioplasty, Peripheral, Transluminal
Device class Class 2
Regulation 21 CFR 870.1250
Establishment Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K103464
Record published 2016-04-28
Record revised 2020-07-20 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Storage Special storage condition: Store at controlled room temperature, in a dry place. Do not expose to organic solvents (e.g. alcohol), ionizing radiati
Sizes Outer diameter 4 to 7 mm; length 150 to 300 mm
Distribution end date 2024-05-22

Catalogue Numbers

Catalogue numbers for Pacific Xtreme
Catalogue number Size Status
PCU050150130 Outer Diameter 5.0 mm In distribution
PCU050150090 Outer Diameter 5.0 mm In distribution
PCU040250130 Outer Diameter 4.0 mm In distribution
PCU040250130 Balloon Diameter 4 MM In distribution
PCU050200090 Balloon Length 200 MM In distribution
PCU040150130 Length 150.0 mm In distribution
PCU060150090 Balloon Diameter 6 MM In distribution
PCU040200090 Length 200.0 mm In distribution
PCU060300130 Balloon Length 300 MM In distribution
PCU040250090 Balloon Diameter 4 MM In distribution
PCU060300090 Balloon Diameter 6 MM In distribution
PCU070150090 Outer Diameter 7.0 mm In distribution
PCU040150090 Balloon Diameter 4 MM In distribution
PCU060250130 Balloon Length 250 MM In distribution
PCU060300130 Outer Diameter 6.0 mm In distribution
PCU040150130 Balloon Diameter 4 MM In distribution
PCU060200090 Balloon Length 200 MM In distribution
PCU060150130 Outer Diameter 6.0 mm In distribution
PCU040300130 Length 300.0 mm In distribution
PCU040300130 Balloon Length 300 MM In distribution
PCU070200090 Length 200.0 mm In distribution
PCU070150130 Outer Diameter 7.0 mm In distribution
PCU070200130 Balloon Diameter 7 MM In distribution
PCU050150090 Balloon Diameter 5 MM In distribution
PCU040300130 Length 300.0 mm In distribution
PCU060250090 Length 250.0 mm In distribution
PCU050300090 Length 300.0 mm In distribution
PCU050250090 Length 250.0 mm In distribution
PCU060150090 Length 150.0 mm In distribution
PCU060200130 Outer Diameter 6.0 mm In distribution
PCU050200130 Length 200.0 mm In distribution
PCU050200130 Outer Diameter 5.0 mm In distribution
PCU060150130 Outer Diameter 6.0 mm In distribution
PCU050150130 Length 150.0 mm In distribution
PCU050250090 Balloon Length 250 MM In distribution
PCU070150130 Length 150.0 mm In distribution
PCU050300130 Outer Diameter 5.0 mm In distribution
PCU040250130 Length 250.0 mm In distribution
PCU040250090 Outer Diameter 4.0 mm In distribution
PCU060200090 Outer Diameter 6.0 mm In distribution
PCU070150090 Balloon Length 150 MM In distribution
PCU060150130 Outer Diameter 6.0 mm In distribution
PCU050300090 Outer Diameter 5.0 mm In distribution
PCU070250130 Outer Diameter 7.0 mm In distribution
PCU050250130 Outer Diameter 5.0 mm In distribution
PCU040150130 Length 150.0 mm In distribution
PCU050300130 Outer Diameter 5.0 mm In distribution
PCU060250130 Outer Diameter 6.0 mm In distribution
PCU070250130 Length 250.0 mm In distribution
PCU060200130 Length 200.0 mm In distribution
PCU050300130 Outer Diameter 5.0 mm In distribution
PCU060200130 Length 200.0 mm In distribution
PCU040300090 Outer Diameter 4.0 mm Withdrawn
PCU060150090 Outer Diameter 6.0 mm Withdrawn
PCU060300090 Outer Diameter 6.0 mm Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Parafleet SC 018 PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 1,460
Jade Plus PTA Balloon Dilatation Catheter / Jade Plus 18 OTW OrbusNeich Medical (Shenzhen) Co., Ltd. 832
Jade PTA Balloon Dilatation Catheter OrbusNeich Medical (Shenzhen) Co., Ltd. 667
Parafleet SC 014 PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 572
Minerva PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 504
Advocate Arravasc, Ltd. 441
Ultraverse® 035 PTA Dilatation Catheter Bard Peripheral Vascular, Inc. 361
Polux PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 359
Advance Cook Incorporated 355
Pacific™ Plus Medtronic, Inc. 347
EverCross™ ev3, Inc. 316
Achilles NC PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 297

Showing 12 of 167. All products under Catheter, Angioplasty, Peripheral, Transluminal

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K213631 2021-12-15
K121265 2012-05-22
K103464 2010-12-22

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Pacific Xtreme
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
ev3, Inc. 510(k) number 2020-08-26 Class II Under Investigation by firm Labeling discrepancy for the Rated Burst Pressure (RBP) value. 4286 devices 2023-06-09

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-11-10 Class II Process control Medtronic identified an issue with specific models and lots of the PowerCross.018 Over the Wire (OTW) Percutaneous Transluminal Angioplasty (PTA) Dilatation Catheter. During an unrelated manufacturing inspection of scrapped products, an ou 315 2017-08-02

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer