SABER.014 PTA Dilatation Catheter

SABER.014 is an over-the-wire balloon catheter for dilating peripheral vascular stenoses, including femoral, popliteal and infrapopliteal arteries. It is also used for postdilation of…

Registry build 21.09.26

SABER.014 is an over-the-wire balloon catheter for dilating peripheral vascular stenoses, including femoral, popliteal and infrapopliteal arteries. It is also used for postdilation of peripheral balloon-expandable or self-expanding stents and is not for coronary arteries.

The coaxial-lumen catheter carries a semicompliant distal balloon and tracks over a 0.014 inch guidewire. Its tapered tip assists entry and stenosis crossing, while a dual-layer hydrophilic coating provides balloon lubricity.

Listed Item

PTA, OTW, 1.5 x 120, 150cm

Balloon Positioning

Radiopaque bands mark the balloon’s dilating section. The SABER.014 range offers 90 cm and 150 cm working lengths, balloon diameters from 1.25 to 5.0 mm and lengths from 15 to 300 mm. Balloon diameter varies with pressure according to its compliance chart.

5manufacturers in China registered for this device type
105catalogue numbers in this listing
1510(k) clearance
6recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Guangdong (2).

Chinese manufacturers registered for FDA product code LIT
Manufacturer City Province Registered as Device types
OrbusNeich Medical (Shenzhen) Co., Ltd. Shenzhen Guangdong Complaint-file establishment 5
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Brosmed Medical Co., Ltd. Dongguan Guangdong Contract manufacturer 4
Kossel Medtech (Suzhou) Co., Ltd. Suzhou Jiangsu Manufacturer 4
DK Medical Technology Co., Ltd. Suzhou Jiangsu Manufacturer 3

Record

Regulatory record for SABER.014 PTA Dilatation Catheter
Listed by Cordis US Corp., United States
FDA product code LIT
Device type Catheter, Angioplasty, Peripheral, Transluminal
Device class Class 2
Regulation 21 CFR 870.1250
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K221832
Record published 2023-07-05
Record revised 2025-09-05 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for SABER.014 PTA Dilatation Catheter
Catalogue number Size Status
47040020M In distribution
47015120M In distribution
47040200M In distribution
47025100S In distribution
47025080S In distribution
47025040S In distribution
47035100M In distribution
47040040M In distribution
47035120M In distribution
47040100M In distribution
47025150S In distribution
47050200S In distribution
47025200M In distribution
47050020S In distribution
47020200S In distribution
47025020S In distribution
47035020M In distribution
47020150M In distribution
47035080M In distribution
47040020S In distribution
47040150M In distribution
47050120S In distribution
47035040M In distribution
47020200M In distribution
47030020S In distribution
47025100M In distribution
47030150S In distribution
47035120S In distribution
47035150S In distribution
47040080M In distribution
47015020M In distribution
47030120M In distribution
47050150S In distribution
47020080M In distribution
47050250M In distribution
47050100M In distribution
47015020S In distribution
47012015S In distribution
47020100S In distribution
47030300S In distribution
47020150S In distribution
47020300S In distribution
47050200M In distribution
47050040M In distribution
47025080M In distribution
47015120S In distribution
47020020S In distribution
47030100M In distribution
47020250M In distribution
47030080M In distribution
47035300S In distribution
47030250S In distribution
47025020M In distribution
47030040S In distribution
47030300M In distribution
47050080M In distribution
47040150S In distribution
47030020M In distribution
47015080M In distribution
47030080S In distribution
47020300M In distribution
47040120M In distribution
47025200S In distribution
47035020S In distribution
47030100S In distribution
47030200M In distribution
47050080S In distribution
47040250M In distribution
47050150M In distribution
47050100S In distribution
47015040M In distribution
47020120M In distribution
47020100M In distribution
47025250S In distribution
47050300M In distribution
47050120M In distribution
47050040S In distribution
47025120M In distribution
47050020M In distribution
47040250S In distribution
47035200M In distribution
47035300M In distribution
47030150M In distribution
47040040S In distribution
47035250S In distribution
47020120S In distribution
47035100S In distribution
47015080S In distribution
47015015S In distribution
47040200S In distribution
47040300S In distribution
47025150M In distribution
47040100S In distribution
47020080S In distribution
47025120S In distribution
47025040M In distribution
47020020M In distribution
47015015M In distribution
47020040S In distribution
47040120S In distribution
47035150M In distribution
47015040S In distribution
47035200S In distribution
47030200S In distribution
47020040M In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Parafleet SC 018 PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 1,460
Jade Plus PTA Balloon Dilatation Catheter / Jade Plus 18 OTW OrbusNeich Medical (Shenzhen) Co., Ltd. 832
Jade PTA Balloon Dilatation Catheter OrbusNeich Medical (Shenzhen) Co., Ltd. 667
Parafleet SC 014 PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 572
Minerva PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 504
Advocate Arravasc, Ltd. 441
Ultraverse® 035 PTA Dilatation Catheter Bard Peripheral Vascular, Inc. 361
Polux PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 359
Advance Cook Incorporated 355
Pacific™ Plus Medtronic, Inc. 347
EverCross™ ev3, Inc. 316
Achilles NC PTA Balloon Dilatation Catheter Brosmed Medical Co., Ltd. 297

Showing 12 of 167. All products under Catheter, Angioplasty, Peripheral, Transluminal

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K221832 2022-08-22

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2021-07-19 Class II Under Investigation by firm The balloon protective sheath may potentially be contaminated with a foreign material left over from the manufacturing process. The contaminant may transfer over from the sheath to the balloon. 8 units 2023-02-16
2020-01-08 Class II Pending Cordis is recalling one (1) lot of POWERFLEX P3 PTA Dilatation Catheter due to the potential for body/shaft voids in the proximal seal area. 89 units 2023-01-13
2019-10-04 Class II Process control Product was manufactured utilizing an expired inner body. 21 units 2020-12-14
2018-09-05 Class II Process control Product may not meet the internal manufacturing shaft subassembly burst strength specification (Failure of the Burst Shaft Test). 162 units total (74 units in USA) 2021-02-11
2014-12-22 Class II Labeling design One unit from a demo lot of POWERFLEX PRO PTA Dilatation Catheter was left at a hospital and was not sterilized. 120 2015-07-09
2005-05-11 Not classified Other During competitive product testing, wire movement difficulties were observed in Powerflex P3 units. Due to the possibility of user inconvenience, Cordis is recalling the six affected lots of Powerflex P3. There is no patient impact. 48 units 2008-11-20

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer