Indeflator
PLUS 30 PRIORITY PACK Accessory Kit includes INDEFLATOR PLUS 30 Inflation Device 30 atm 10 cc / Rotating Hemostatic Valve .096 " / Guide Wire Introducer / Torque Device
Who Else Makes It
Concentrated in Guangdong (2), Jiangsu (1), Fujian (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Forefront Medical Technology (Jiangsu) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 14 |
| Forefront (Xiamen) Medical Devices Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 8 |
| Tianjin Demax Medical Technology Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 5 |
| Sunny Medical Device (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 11 |
| Beijing Demax Medical Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 5 |
| Shenzhen Antmed Co., Ltd. | Dongguan | Guangdong | Manufacturer | 4 |
Record
| Listed by | Abbott Vascular, United States |
|---|---|
| FDA product code | MAV |
| Device type | Syringe, Balloon Inflation |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1650 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2016-08-05 |
| Record revised | 2024-08-26 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Store in a dry, dark, cool place. |
| Distribution end date | 2023-01-20 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1000186-115 | In distribution | |
| 1000184 | In distribution | |
| 1000186 | In distribution | |
| 1000185-115 | Withdrawn | |
| 1000183 | Withdrawn | |
| 1000185 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Demax | Beijing Demax Medical Technology Co., Ltd. | 18 |
| Everest™ | Medtronic, Inc. | 16 |
| basixCOMPAK™ | Merit Medical Systems, Inc. | 16 |
| QL Disposable Inflation Device | Atrion Medical Products, Inc. | 15 |
| basixTOUCH™ | Merit Medical Systems, Inc. | 12 |
| Fluent™ inflation device | Vascular Solutions LLC | 10 |
| DeRoyal | Deroyal Industries, Inc. | 4 |
| QL Locking Syringe Device | Atrion Medical Products, Inc. | 4 |
| QL® Inflation Device | Atrion Medical Products, Inc. | 4 |
| Sphere™ Inflation Device | Atrion Medical Products, Inc. | 3 |
| Medex | ICU Medical, Inc | 3 |
| DiamondTOUCH™ | Merit Medical Systems, Inc. | 3 |
Showing 12 of 39. All products under Syringe, Balloon Inflation
Recalls Naming This Product
7 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Abbott Vascular | UDI-DI | 2024-11-06 | Class II | Component change control | Inflation Device used during cardiovascular procedures may leak in the indeflator at the hose rotating luer or at the gauge, which could lead to air embolism. | 1,418 |
| Abbott Vascular | UDI-DI | 2024-11-06 | Class II | Component change control | Inflation Device used during cardiovascular procedures may leak in the indeflator at the hose rotating luer or at the gauge, which could lead to air embolism. | 3,673 |
| Abbott Vascular | UDI-DI | 2024-11-06 | Class II | Component change control | Inflation Device used during cardiovascular procedures may leak in the indeflator at the hose rotating luer or at the gauge, which could lead to air embolism. | 4,975 |
| Abbott Vascular | UDI-DI | 2022-03-11 | Class II | Component change control | Due to an increase in complaint trend for leaks and intermittent/loose connections. | 17 lots |
| Abbott Vascular | UDI-DI | 2022-03-11 | Class II | Component change control | Due to an increase in complaint trend for leaks and intermittent/loose connections. | 23 lots |
| Abbott Vascular | UDI-DI | 2022-03-11 | Class II | Component change control | Due to an increase in complaint trend for leaks and intermittent/loose connections. | 6 lots |
| Abbott Vascular | UDI-DI | 2022-03-11 | Class II | Component change control | Due to an increase in complaint trend for leaks and intermittent/loose connections. | 7 lots |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2024-11-06 | Class II | Component change control | Inflation Device used during cardiovascular procedures may leak in the indeflator at the hose rotating luer or at the gauge, which could lead to air embolism. | 23,407 |
| 2022-03-11 | Class II | Component change control | Due to an increase in complaint trend for leaks and intermittent/loose connections. | 131 lots |
| 2018-07-03 | Class II | Incorrect or no expiration date | Incorrect expiration being entered for one lot. | 26 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.