ACE

RC ACE 64, 127cm

Registry build 21.09.26
5manufacturers in China registered for this device type
14catalogue numbers in this listing
25510(k) clearances naming this product code
7recalls on this code

Who Else Makes It

Concentrated in Shanghai (3), Jiangsu (2). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code NRY
Manufacturer City Province Registered as Device types
Covidien Medical Products (Shanghai) Manufacturing LLC Shanghai Shanghai Contract manufacturer 8
Sterigenics Shanghai ETO Ltd. Shanghai Shanghai Contract manufacturer 65
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Suzhou Zenith Vascular Scitech Limited Suzhou Jiangsu Manufacturer 6
Shanghai Wallaby Medical Technologies Co., Inc. Shanghai Shanghai Contract manufacturer 5

Record

Regulatory record for ACE
Listed by Penumbra Inc., United States
FDA product code NRY
Device type Catheter, Thrombus Retriever
Device class Class 2
Regulation 21 CFR 870.1250
Establishment Manufacturer, Exporter
510(k) K142458
Record published 2020-05-06
Record revised 2026-02-25 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date, serial number

Catalogue Numbers

Catalogue numbers for ACE
Catalogue number Size Status
5MAXACE068-R In distribution
5MAXACE064L127 In distribution
5MAXACE064 In distribution
5MAXACE068KIT In distribution
5MAXACE068L120 In distribution
5MAXACE064L115 In distribution
5MAXACE068L127 In distribution
5MAXACE068L125 In distribution
5MAXACE068 In distribution
5MAXACE064L120 In distribution
5MAXACE068KIT-R In distribution
5MAXACE064KIT In distribution
5MAXACE064L125 In distribution
5MAXACE068L115 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Penumbra System Penumbra Inc. 100
RED 43 Penumbra Inc. 18
Solitaire™ X-Pack Micro Therapeutics, Inc. 14
Raptor Aspiration Catheter Balt USA, LLC 13
Cereglide Cerenovus, Inc. 13
Solitaire™ Micro Therapeutics, Inc. 9
Solitaire™ X Micro Therapeutics, Inc. 9
RED 68 Penumbra Inc. 9
Riptide™ Micro Therapeutics, Inc. 9
Zoom™ Reperfusion Catheter Imperative Care Inc. 9
CaptureTM Micro Therapeutics, Inc. 8
Esperance Shanghai Wallaby Medical Technologies Co., Inc. 6

Showing 12 of 80. All products under Catheter, Thrombus Retriever

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K250690 2026-06-10
K242104 2025-02-13
K222808 2022-12-20
K211654 2021-08-16
K211411 2021-07-01
K203440 2021-05-20
K202251 2020-08-31
K191946 2020-02-27
K190010 2019-06-16
K190464 2019-04-26
K182522 2018-10-12
K173761 2018-08-17
K180008 2018-06-20
K162901 2017-04-20
K161640 2016-07-12
K161064 2016-06-12
K160449 2016-05-25
K152541 2016-01-13
K151623 2015-08-06
K142458 2015-05-22
K133317 2014-05-13
K113163 2011-11-23
K100769 2010-05-21
K090752 2009-09-21
K072718 2007-12-28

Recalls

5 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-06-03 Class II Under Investigation by firm Due to manufacturing issues, reperfusion catheters may fractures
2020-12-15 Class I Process design The catheter may become susceptible to distal tip damage during use. Distal tip damage in conjunction with pressurization of contrast injection may result in potential vessel damage, and subsequent patient injury or death. 0 catheters 2024-05-14
2020-12-15 Class I Process design The catheter may become susceptible to distal tip damage during use. Distal tip damage in conjunction with pressurization of contrast injection may result in potential vessel damage, and subsequent patient injury or death. 3,368 catheters 2024-05-14
2020-12-15 Class I Process design The catheter may become susceptible to distal tip damage during use. Distal tip damage in conjunction with pressurization of contrast injection may result in potential vessel damage, and subsequent patient injury or death. 15 catheters 2024-05-14
2020-12-15 Class I Process design The catheter may become susceptible to distal tip damage during use. Distal tip damage in conjunction with pressurization of contrast injection may result in potential vessel damage, and subsequent patient injury or death. 27,499 catheters 2024-05-14
2017-06-09 Class I Component change control Penumbra has identified an issue in these four lots involving a raw material component of the delivery wire. This issue could result in breakage of the delivery wire, which could potentially lead to serious patient injury or death. 155 units 2019-05-09
2010-10-25 Not classified Process control Reperfusion catheter may fail at the mid-shaft joint and may break off. If the segment cannot be removed, it may result in blocked blood flow, requiring emergency medical treatment. 61 2011-06-01

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer