ComboMap Pressure and Flow System

Catalogue number 6800, listed by Volcano Corporation, United States, under Catheter, Ultrasound, Intravascular. 4 manufacturers in China are registered for this product code.

Registry build 21.09.26
4manufacturers in China registered for this device type
1catalogue number
14510(k) clearances naming this product code
10recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code OBJ
Manufacturer City Province Registered as Device types
Philips Ultrasound (Shanghai) Co., Ltd. Shanghai Shanghai Contract manufacturer 5
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Jiangsu Tingsn Technology Co., Ltd. Nanjing Jiangsu Manufacturer 4
Nanjing Shuangwei Biotechnology Co., Ltd. Nanjing Jiangsu Contract manufacturer 1

Record

Regulatory record for ComboMap Pressure and Flow System
Listed by Volcano Corporation, United States
FDA product code OBJ
Device type Catheter, Ultrasound, Intravascular
Device class Class 2
Regulation 21 CFR 870.1200
Establishment Specification developer, Complaint-file establishment, Manufacturer
Record published 2016-12-08
Record revised 2022-01-26 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for ComboMap Pressure and Flow System
Catalogue number Size Status
6800 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arrow Teleflex Medical LLC 27
Acist HDi® HD Ivus System Acist Medical Systems, Inc. 8
Soundstar Biosense Webster, Inc. 6
OptiCross Boston Scientific Corporation 4
Busse Hospital Disposables Robert Busse & Co., Inc. 4
Acist HDi® System Console Acist Medical Systems, Inc. 4
OptiCross™ 6 Boston Scientific Corporation 3
7 Fr PV-Catheter CD Leycom 3
NES Reprocessed Visions PV.014P RX Digital Ivus Catheter North East Scientific Inc 3
OptiCross™ 6 HD Boston Scientific Corporation 2
Acist HDi® Bed Rail Mount Acist Medical Systems, Inc. 2
4 Fr PV Catheter CD Leycom 2

Showing 12 of 63. All products under Catheter, Ultrasound, Intravascular

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K160583 2016-10-26
K153094 2015-12-31
K152829 2015-11-19
K150442 2015-09-04
K143701 2015-08-26
K121273 2012-09-10
K120697 2012-04-05
K092596 2009-12-10
K080891 2008-05-12
K073473 2008-01-14
K071554 2008-01-04
K071660 2007-08-31
K051337 2005-08-18
K050995 2005-06-20

Recalls

8 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-06-13 Class II Reports of IVUS catheter and guide wire entanglement during radial-to-peripheral procedures, due to catheter use without appropriate sheath and/or guide catheter, which may require further intervention, such as surgical removal; Firm is res 233,817
2022-05-13 Class III Process control Digital IVUS catheter instructions for use ( IFU) do not contain contrainidications 7,520 units
2022-05-13 Class III Process control Digital IVUS catheter instructions for use ( IFU) do not contain contrainidications 14.031 units
2018-10-17 Class II Under Investigation by firm Visions PV.035 Intravascular Ultrasound (IVUS) Catheters (catalog number 88901 adnd81234) due to the potential inability to pass the guidewire through the y-port of the catheter. 6870 units 2021-04-30
2018-10-17 Class II Under Investigation by firm Visions PV.035 Intravascular Ultrasound (IVUS) Catheters (catalog number 88901 adnd81234) due to the potential inability to pass the guidewire through the y-port of the catheter. 1240 units 2021-04-30
2017-11-03 Class II Software design On certain Impacted Systems, an unexpected Microsoft Windows Security dialog may appear during use, and the users response to the dialog may adversely affect the subsequent operation of the device. 1166 Units 2023-10-20
2017-03-29 Class II Under Investigation by firm High complaint rates of kinking near the junction of the proximal shaft to telescope section of the catheter. Kinking could result in disruption of normal clinical workflow or loss of imaging. 718 total devices 2017-06-21
2017-03-29 Class II Under Investigation by firm High complaint rates of kinking near the junction of the proximal shaft to telescope section of the catheter. Kinking could result in disruption of normal clinical workflow or loss of imaging. 718 total units 2017-06-21
2016-04-25 Class II Software in the Use Environment Volcano has become aware of an incompatibility issue between Impacted Systems and hospital network scans. In specific circumstances, an impacted System will encounter unexpected data from the hospital network and be forced to reboot 5875 (2685 in US; 3190 ROW) 2018-01-02
2015-06-04 Class II Labeling mix-ups During a relabeling procedure at the manufacturing facility, the products were labeled with a shelf life in accordance with the date of the relabeling and not in accordance with the original shelf life date at the time of manufacture 162 total devices (included both products) 2015-10-27

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer