Nuvision NAV Ultrasound Catheter

The Nuvision NAV Ultrasound Catheter provides intracardiac and intraluminal images of the heart, great vessels and other devices in the heart. It is a sterile, single-use 10F imaging…

Registry build 21.09.26

The Nuvision NAV Ultrasound Catheter provides intracardiac and intraluminal images of the heart, great vessels and other devices in the heart. It is a sterile, single-use 10F imaging catheter that also supplies location information to a compatible CARTO 3 navigation system.

A two-dimensional acoustic array and integrated electronics at the distal tip produce real-time two-dimensional, three-dimensional and multiplane views. Handle knobs independently control catheter deflection and transducer rotation, with the imaging field extending sideways from the tip.

Listed Item

NUVISION NAV Ultrasound Catheter, 10F

Compatible Systems

The catheter is validated for the GE Vivid S70N ultrasound system and CARTO 3 with CARTOSOUND 4D, connected through the specified cables. It provides imaging guidance and location, not treatment delivery.

4manufacturers in China registered for this device type
2catalogue numbers in this listing
9510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code OBJ
Manufacturer City Province Registered as Device types
Philips Ultrasound (Shanghai) Co., Ltd. Shanghai Shanghai Contract manufacturer 5
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Jiangsu Tingsn Technology Co., Ltd. Nanjing Jiangsu Manufacturer 4
Nanjing Shuangwei Biotechnology Co., Ltd. Nanjing Jiangsu Contract manufacturer 1

Record

Regulatory record for Nuvision NAV Ultrasound Catheter
Listed by Biosense Webster, Inc., United States
FDA product code OBJ
Device type Catheter, Ultrasound, Intravascular
Device class Class 2
Regulation 21 CFR 870.1200
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K223766
Record published 2023-07-03

Specifications

Specifications
MRI safety MR Unsafe
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Storage Special storage condition: Liquid-tight (catheter shaft only); Special storage condition: Keep away from Sunlight; Storage environment temperature -30 to 60 °C; Special storage condition: Keep dry; Special storage condition: Do not use if package is damaged; Handling environment humidity 10 to 90 % RH

Catalogue Numbers

Catalogue numbers for Nuvision NAV Ultrasound Catheter
Catalogue number Size Status
FG11656 In distribution
FG12081 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arrow Teleflex Medical LLC 27
Acist HDi® HD Ivus System Acist Medical Systems, Inc. 8
Soundstar Biosense Webster, Inc. 6
OptiCross Boston Scientific Corporation 4
Busse Hospital Disposables Robert Busse & Co., Inc. 4
Acist HDi® System Console Acist Medical Systems, Inc. 4
OptiCross™ 6 Boston Scientific Corporation 3
7 Fr PV-Catheter CD Leycom 3
NES Reprocessed Visions PV.014P RX Digital Ivus Catheter North East Scientific Inc 3
OptiCross™ 6 HD Boston Scientific Corporation 2
Acist HDi® Bed Rail Mount Acist Medical Systems, Inc. 2
4 Fr PV Catheter CD Leycom 2

Showing 12 of 63. All products under Catheter, Ultrasound, Intravascular

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K241540 2024-06-28
K240050 2024-06-12
K223766 2023-02-16
K140318 2014-03-12
K112050 2011-11-18
K101138 2010-06-22
K091352 2009-12-04
K092064 2009-08-07
K070242 2007-05-15

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2015-09-10 Class II Device Design Image disappeared from the cardiac ultrasound system when the CARTO 3 EP Navigation System needed restarting while the patient was experiencing pericardial effusion. Affects the CARTOSOUND Module of the CARTO 3 EP Navigation System when us 1035 (U.S.) 2016-05-13

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer