Refinity ST Rotational Ivus Catheter
Catalogue number 89900, listed by Philips Image Guided Therapy Corporation, United States, under Catheter, Ultrasound, Intravascular. 4 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Philips Ultrasound (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 5 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Jiangsu Tingsn Technology Co., Ltd. | Nanjing | Jiangsu | Manufacturer | 4 |
| Nanjing Shuangwei Biotechnology Co., Ltd. | Nanjing | Jiangsu | Contract manufacturer | 1 |
Record
| Listed by | Philips Image Guided Therapy Corporation, United States |
|---|---|
| FDA product code | OBJ |
| Device type | Catheter, Ultrasound, Intravascular |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1200 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K160583 |
| Record published | 2016-11-09 |
| Record revised | 2025-01-22 (version 10) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: Keep dry; Special storage condition: Keep away from sunlight |
| Sizes | Length 135 cm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 89900 | Length 135 cm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arrow | Teleflex Medical LLC | 27 |
| Acist HDi® HD Ivus System | Acist Medical Systems, Inc. | 8 |
| Soundstar | Biosense Webster, Inc. | 6 |
| OptiCross | Boston Scientific Corporation | 4 |
| Busse Hospital Disposables | Robert Busse & Co., Inc. | 4 |
| Acist HDi® System Console | Acist Medical Systems, Inc. | 4 |
| OptiCross™ 6 | Boston Scientific Corporation | 3 |
| 7 Fr PV-Catheter | CD Leycom | 3 |
| NES Reprocessed Visions PV.014P RX Digital Ivus Catheter | North East Scientific Inc | 3 |
| OptiCross™ 6 HD | Boston Scientific Corporation | 2 |
| Acist HDi® Bed Rail Mount | Acist Medical Systems, Inc. | 2 |
| 4 Fr PV Catheter | CD Leycom | 2 |
Showing 12 of 63. All products under Catheter, Ultrasound, Intravascular
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K251103 | 2025-05-09 |
| K200812 | 2020-09-02 |
| K200410 | 2020-05-22 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Volcano Corporation | 510(k) number | 2017-03-29 | Class II | Under Investigation by firm | High complaint rates of kinking near the junction of the proximal shaft to telescope section of the catheter. Kinking could result in disruption of normal clinical workflow or loss of imaging. | 718 total units | 2017-06-21 |
| Volcano Corporation | 510(k) number | 2017-03-29 | Class II | Under Investigation by firm | High complaint rates of kinking near the junction of the proximal shaft to telescope section of the catheter. Kinking could result in disruption of normal clinical workflow or loss of imaging. | 718 total devices | 2017-06-21 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.