Vascular Access Introducer Set

2 catalogue numbers from CLI-224-055, listed by Galt Medical Corp., United States, under Percutaneous Sheath Introducer Kit. 2 manufacturers in China are registered for this product code.

Registry build 21.09.26
2manufacturers in China registered for this device type
2catalogue numbers in this listing
2recalls on this code

Who Else Makes It

Concentrated in Zhejiang (1), Shanghai (1).

Chinese manufacturers registered for FDA product code OFL
Manufacturer City Province Registered as Device types
GRI Medical & Electronic Technology Co., Ltd. Jiaxing Zhejiang Contract manufacturer 71
Shanghai INT Medical Instruments Co., Ltd. Shanghai Shanghai Contract manufacturer 10

Record

Regulatory record for Vascular Access Introducer Set
Listed by Galt Medical Corp., United States
FDA product code OFL
Device type Percutaneous Sheath Introducer Kit
Device class Class 2
Regulation 21 CFR 870.1340
Establishment Contract manufacturer, Repacker / relabeller, Complaint-file establishment, Manufacturer
Premarket notification Exempt
Record published 2018-02-06
Record revised 2024-03-20 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Ethylene Oxide
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date, serial number
Packaging Shipper box of 50, shelf box of 5
Sizes Catheter gauge 5 to 6 Fr

Catalogue Numbers

Catalogue numbers for Vascular Access Introducer Set
Catalogue number Size Status
CLI-224-055 Catheter Gauge 5 Fr In distribution
CLI-224-065 Catheter Gauge 6 Fr In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Micro-Introducer Kit Galt Medical Corp. 53
Micro-Access Tearaway Introducer Kit Galt Medical Corp. 49
Tearaway Introducer Kit Galt Medical Corp. 35
Stiffen Micro-Introducer Kit Galt Medical Corp. 28
Elite Transitionless Micro-Introducer Kit Galt Medical Corp. 24
Valved Tearaway Kit Galt Medical Corp. 24
Typenex Introducer Set Typenex Medical, LLC 23
Transitionless Micro-Introducer Kit Galt Medical Corp. 20
Transitionless Stiffen Micro-Introducer Kit Galt Medical Corp. 19
Seamless™ B. Braun Medical Inc. 19
Stradis Stradis Healthcare 16
TVS LPA Galt Medical Corp. 13

Showing 12 of 40. All products under Percutaneous Sheath Introducer Kit

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2025-03-27 Class II Process control Due to a potential open seal in the sterile barrier packaging. 4,280 kits
2025-03-27 Class II Process control Due to a potential open seal in the sterile barrier packaging. 490 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer