070 Access System
070 Access System; Contains Tenzing 7 delivery catheter (00853799007541) and 070 Catheter (00853799007459)
Who Else Makes It
Concentrated in Shanghai (4), Jiangsu (2). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Covidien Medical Products (Shanghai) Manufacturing LLC | Shanghai | Shanghai | Contract manufacturer | 8 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Shanghai Wallaby Medical Technologies Co., Inc. | Shanghai | Shanghai | Contract manufacturer | 5 |
| Shanghai Heartcare Medical Technology Corporation Limited | Shanghai | Shanghai | Manufacturer | 2 |
Record
| Listed by | Route 92 Medical, Inc., United States |
|---|---|
| FDA product code | QJP |
| Device type | Catheter, Percutaneous, Neurovasculature |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1250 |
| Record published | 2024-05-17 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Gen 1 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Saya 86 | Asahi Intecc Co., Ltd. | 12 |
| Cereglide | Cerenovus, Inc. | 9 |
| Branchor X | Asahi Intecc Co., Ltd. | 9 |
| Stellar Guide Catheter | Balt USA, LLC | 8 |
| Esperance | Shanghai Wallaby Medical Technologies Co., Inc. | 6 |
| Fubuki XF | Asahi Intecc Co., Ltd. | 5 |
| Fubuki XF-R | Asahi Intecc Co., Ltd. | 4 |
| Apro 45 Intermediate Catheter | Alembic LLC | 4 |
| Apro 55 Intermediate Catheter | Alembic LLC | 4 |
| 87 NeuGlide Catheter | Piraeus Medical, Inc. | 4 |
| ACCESS25 Delivery Microcatheter | Penumbra Inc. | 4 |
| Midway | Penumbra Inc. | 4 |
Showing 12 of 54. All products under Catheter, Percutaneous, Neurovasculature
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K240529 | 2024-10-02 |
| K231583 | 2023-08-15 |
| K222743 | 2022-10-04 |
| K210635 | 2021-07-27 |
| K203043 | 2020-11-11 |
| K201518 | 2020-08-14 |
| K200121 | 2020-04-18 |
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Route 92 Medical, Head Quarters | UDI-DI | 2024-03-08 | Class I | Process control | Their is the potential for distal tip separation at the proximal marker band of the delivery catheters | 117 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.