Emboguard
The EMBOGUARD Balloon Guide Catheter guides an intravascular catheter into a selected vessel in the neurovascular system. Its balloon provides temporary vascular occlusion during…
The EMBOGUARD Balloon Guide Catheter guides an intravascular catheter into a selected vessel in the neurovascular system. Its balloon provides temporary vascular occlusion during angiographic procedures.
The filing also identifies the catheter as a conduit for retrieval devices. The described construction includes a compliant distal balloon, an eccentric inflation lumen, a radiopaque marker and a bifurcated proximal luer hub.
Listed Item
EMBOGUARD Balloon Guide Catheter
Construction
The device shaft has a hydrophilic coating near the distal end, and the product label provides its dimensions. The FDA summary identifies the subject device as EMBOGUARD Balloon Guide Catheter.
Who Else Makes It
Concentrated in Shanghai (4), Jiangsu (2). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Covidien Medical Products (Shanghai) Manufacturing LLC | Shanghai | Shanghai | Contract manufacturer | 8 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Shanghai Wallaby Medical Technologies Co., Inc. | Shanghai | Shanghai | Contract manufacturer | 5 |
| Shanghai Heartcare Medical Technology Corporation Limited | Shanghai | Shanghai | Manufacturer | 2 |
Record
| Listed by | Neuravi Limited, Ireland |
|---|---|
| FDA product code | QJP |
| Device type | Catheter, Percutaneous, Neurovasculature |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1250 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K212340 |
| Record published | 2021-12-22 |
| Record revised | 2024-04-23 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| BG8795U | In distribution | |
| BG8785U | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Saya 86 | Asahi Intecc Co., Ltd. | 12 |
| Cereglide | Cerenovus, Inc. | 9 |
| Branchor X | Asahi Intecc Co., Ltd. | 9 |
| Stellar Guide Catheter | Balt USA, LLC | 8 |
| Esperance | Shanghai Wallaby Medical Technologies Co., Inc. | 6 |
| Fubuki XF | Asahi Intecc Co., Ltd. | 5 |
| Fubuki XF-R | Asahi Intecc Co., Ltd. | 4 |
| Apro 45 Intermediate Catheter | Alembic LLC | 4 |
| Apro 55 Intermediate Catheter | Alembic LLC | 4 |
| 87 NeuGlide Catheter | Piraeus Medical, Inc. | 4 |
| ACCESS25 Delivery Microcatheter | Penumbra Inc. | 4 |
| Midway | Penumbra Inc. | 4 |
Showing 12 of 54. All products under Catheter, Percutaneous, Neurovasculature
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K233924 | 2024-04-18 |
| K212340 | 2021-12-17 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.