Carescape
Catalogue number Monitor B650, listed by GE Healthcare Finland OY, Finland, under Oximeter. 70 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (46), Jiangsu (7), Beijing (5). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Tianjin Choice Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 12 |
| Taijia Medical Electronics (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| EMI (Dongguan) Asia Limited | Dongguan | Guangdong | Contract manufacturer | 9 |
| Wuhan Strong Electronics | Wuhan | Hubei | Contract manufacturer | 6 |
| Regent Electron Suzhou Co., Ltd. | Wujiang | Jiangsu | Contract manufacturer | 5 |
| Dongguan Ruibaolian Medical Science & Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 4 |
| Dongguan Kepler Special Cabling Company Limited | Dongguan | Guangdong | Contract manufacturer | 3 |
| Measurement Specialties Chengdu | Chengdu | Sichuan | Contract manufacturer | 3 |
| Beijing Kingst Commercial & Trade Co., Ltd. | Beijing | Beijing | Contract manufacturer | 2 |
| Suzhou Meccan Import and Export Corp. | Suzhou | Jiangsu | Contract manufacturer | 71 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
Showing 12 of 70. All 70 manufacturers in China registered for Oximeter
Record
| Listed by | GE Healthcare Finland OY, Finland |
|---|---|
| FDA product code | DQA |
| Device type | Oximeter |
| Device class | Class 2 |
| Regulation | 21 CFR 870.2700 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K131223 |
| Record published | 2016-06-03 |
| Record revised | 2021-11-10 (version 6) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Storage environment humidity 10 to 90 % RH; Handling environment humidity 10 to 90 % RH; Storage environment temperature -20 to 60 °C; Handling environment atmospheric pressure 70 to 106 KiloPascal; Storage environment atmospheric pressure 50 to 106 KiloPascal; Handling environment temperature 10 to 35 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Monitor B650 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Unimed | Unimed Medical Supplies Inc | 2,838 |
| APK | APK Technology Co., Ltd. | 2,678 |
| ChoiceMMed | Beijing Choice Electronic Technology Co., Ltd. | 151 |
| Nellcor | Covidien LP | 138 |
| Nonin | Nonin Medical, Inc. | 129 |
| Orantech | Orantech Inc. | 97 |
| Med-link | Shenzhen MED-Link Electronics Tech Co., Ltd. | 93 |
| Welch Allyn, Inc. | Welch Allyn, Inc. | 66 |
| Medichoice | Owens & Minor Distribution, Inc. | 62 |
| Caremed | Shenzhen Caremed Medical Technology Co., Ltd. | 55 |
| Sensoronics | Sensoronics Incorporated | 53 |
| Virtuox | Healthcare Logistics Systems | 36 |
Showing 12 of 1,063. All products under Oximeter
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K132696 | 2013-09-27 |
| K103802 | 2011-08-02 |
| K101871 | 2010-10-04 |
| K093881 | 2010-03-12 |
| K081870 | 2008-07-31 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| GE Healthcare Finland OY | 510(k) number | 2018-05-25 | Class II | Software design | When multiple CARESCAPE Monitor B650 units are connected to the same network and a network overload occurs for a prolonged time, the monitors may simultaneously restart as designed. The monitor restart will not be completed until the netwo | 69231 units | |
| GE Medical Systems, LLC | 510(k) number | 2015-05-04 | Class II | Software design | The heart rate could be calculated from pacer pulses without indication that pacemaker detection is OFF in some combinations of Bx50 monitors, a PDM, and CIC/CSCS. Then the monitor does not show the Pacer Off message and there may not be an | 110 (83 units US, 27 units OUS) | 2015-09-15 |
| GE Medical Systems, LLC | 510(k) number | 2014-06-13 | Class II | Software design | Partial loss of monitoring with the CARESCAPE Monitor B850, B650 or B450. When connecting the PDM (Patient Data Module) to the CARESCAPE B850, B650 or B450 monitor with software version 2 the PDM may not start communicating to the monitor | 41,992 (20,509 US; 21,483 OUS) | 2016-09-07 |
| GE Medical Systems, LLC | 510(k) number | 2014-02-28 | Class II | Software design | GE Healthcare has recently become aware of potential safety issues associated with the CARESCAPE Monitor B850 and CARESCAPE Monitor B650. These issues include both NIBP (Non-Invasive Blood Pressure) and Bed to Bed Issues. | 676 units OUS | 2015-04-29 |