Nasal Alar Sp02 Sensor
The Assurance® Nasal Alar SpO2™ Sensor is indicated for single patient use for continuous noninvasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate…
The Assurance® Nasal Alar SpO2™ Sensor is indicated for single patient use for continuous noninvasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate from the nasal ala of adult and pediatric patients, (weighing > 30kg). The sensor can be used in a variety of healthcare environments where compatible pulse oximetry monitors are indicated for use, under professional supervision. The Assurance® Nasal Alar SpO2™ Sensor is for use with compatible pulse oximeters. These include: Nellcor OxiMax and Oxisensor II compatible monitors and Philips FAST compatible monitors.
Who Else Makes It
Concentrated in Guangdong (46), Jiangsu (7), Beijing (5). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Tianjin Choice Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 12 |
| Taijia Medical Electronics (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| EMI (Dongguan) Asia Limited | Dongguan | Guangdong | Contract manufacturer | 9 |
| Wuhan Strong Electronics | Wuhan | Hubei | Contract manufacturer | 6 |
| Regent Electron Suzhou Co., Ltd. | Wujiang | Jiangsu | Contract manufacturer | 5 |
| Dongguan Ruibaolian Medical Science & Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 4 |
| Dongguan Kepler Special Cabling Company Limited | Dongguan | Guangdong | Contract manufacturer | 3 |
| Measurement Specialties Chengdu | Chengdu | Sichuan | Contract manufacturer | 3 |
| Beijing Kingst Commercial & Trade Co., Ltd. | Beijing | Beijing | Contract manufacturer | 2 |
| Suzhou Meccan Import and Export Corp. | Suzhou | Jiangsu | Contract manufacturer | 71 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
Showing 12 of 70. All 70 manufacturers in China registered for Oximeter
Record
| Listed by | Xhale Assurance, Inc. |
|---|---|
| FDA product code | DQA |
| Device type | Oximeter |
| Device class | Class 2 |
| Regulation | 21 CFR 870.2700 |
| Record published | 2017-03-17 |
| Record revised | 2021-11-10 (version 3) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Packaging | Box of 24, carton of 6, shipping carton of 6, case of 20 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 301-11214 | In distribution | |
| 0303 | In distribution | |
| 0201-A01 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Unimed | Unimed Medical Supplies Inc | 2,838 |
| APK | APK Technology Co., Ltd. | 2,678 |
| ChoiceMMed | Beijing Choice Electronic Technology Co., Ltd. | 151 |
| Nellcor | Covidien LP | 138 |
| Nonin | Nonin Medical, Inc. | 129 |
| Orantech | Orantech Inc. | 97 |
| Med-link | Shenzhen MED-Link Electronics Tech Co., Ltd. | 93 |
| Welch Allyn, Inc. | Welch Allyn, Inc. | 66 |
| Medichoice | Owens & Minor Distribution, Inc. | 62 |
| Caremed | Shenzhen Caremed Medical Technology Co., Ltd. | 55 |
| Sensoronics | Sensoronics Incorporated | 53 |
| Virtuox | Healthcare Logistics Systems | 36 |
Showing 12 of 1,063. All products under Oximeter
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2019-05-08 | Class II | Device Design | These Instructions for Use has missing instructions related to the checking and changing of the application site procedure. | 701,272 devices total | 2022-04-25 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.