Rainbow® DCI-dc3 SpCO® SpMet® SpO2 Adult Direct Connect Reusable Sensor

rainbow DCI-dc3 SpCO SpMet SpO2 Adult Direct Connect Reusable Sensor

Registry build 21.09.26
70manufacturers in China registered for this device type
1catalogue number
77510(k) clearances naming this product code
14recalls on this code

Who Else Makes It

Concentrated in Guangdong (46), Jiangsu (7), Beijing (5). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DQA
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Tianjin Choice Medical Device Co., Ltd. Tianjin Tianjin Contract manufacturer 12
Taijia Medical Electronics (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 10
EMI (Dongguan) Asia Limited Dongguan Guangdong Contract manufacturer 9
Wuhan Strong Electronics Wuhan Hubei Contract manufacturer 6
Regent Electron Suzhou Co., Ltd. Wujiang Jiangsu Contract manufacturer 5
Dongguan Ruibaolian Medical Science & Technology Co., Ltd. Dongguan Guangdong Contract manufacturer 4
Dongguan Kepler Special Cabling Company Limited Dongguan Guangdong Contract manufacturer 3
Measurement Specialties Chengdu Chengdu Sichuan Contract manufacturer 3
Beijing Kingst Commercial & Trade Co., Ltd. Beijing Beijing Contract manufacturer 2
Suzhou Meccan Import and Export Corp. Suzhou Jiangsu Contract manufacturer 71
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61

Showing 12 of 70. All 70 manufacturers in China registered for Oximeter

Record

Regulatory record for rainbow® DCI-dc3 SpCO® SpMet® SpO2 Adult Direct Connect Reusable Sensor
Listed by Masimo Corporation, United States
FDA product code DQA
Device type Oximeter
Device class Class 2
Regulation 21 CFR 870.2700
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K080238
Record published 2016-08-23
Record revised 2025-12-22 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, manufacturing date
Storage Handling environment humidity 15 to 95 % RH; Handling environment temperature -40 to 70 °C; Storage environment humidity 15 to 95 % RH; Storage environment temperature -40 to 70 °C

Catalogue Numbers

Catalogue numbers for rainbow® DCI-dc3 SpCO® SpMet® SpO2 Adult Direct Connect Reusable Sensor
Catalogue number Size Status
2201 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Unimed Unimed Medical Supplies Inc 2,838
APK APK Technology Co., Ltd. 2,678
ChoiceMMed Beijing Choice Electronic Technology Co., Ltd. 151
Nellcor Covidien LP 138
Nonin Nonin Medical, Inc. 129
Orantech Orantech Inc. 97
Med-link Shenzhen MED-Link Electronics Tech Co., Ltd. 93
Welch Allyn, Inc. Welch Allyn, Inc. 66
Medichoice Owens & Minor Distribution, Inc. 62
Caremed Shenzhen Caremed Medical Technology Co., Ltd. 55
Sensoronics Sensoronics Incorporated 53
Virtuox Healthcare Logistics Systems 36

Showing 12 of 1,063. All products under Oximeter

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K223721 2023-12-15
K232389 2023-09-07
K213676 2023-04-16
K221953 2022-08-04
K212876 2021-10-08
K201770 2020-09-24
K182887 2019-03-22
K181956 2019-01-23
K180046 2018-10-23
K162675 2016-12-28
K160940 2016-11-23
K150314 2015-10-22
K120984 2013-04-26
K120657 2012-09-19
K121914 2012-09-07
K121912 2012-07-24
K113596 2012-02-24
K111403 2011-12-30
K111621 2011-10-26
K111888 2011-09-23
K110028 2011-03-17
K101031 2010-11-18
K101896 2010-10-21
K100428 2010-07-09
K100403 2010-06-23
K100617 2010-05-28
K094046 2010-05-14
K091241 2009-11-06
K092838 2009-10-15
K090662 2009-08-10
K091057 2009-07-09
K090165 2009-07-09
K083622 2009-04-02
K082052 2008-10-10
K081659 2008-09-09
K080238 2008-05-12
K073024 2008-02-08
K071024 2007-06-29
K063140 2006-12-29
K061204 2006-07-27
K060143 2006-06-16
K053477 2006-03-16
K053269 2005-12-21
K051439 2005-07-15
K051212 2005-07-12
K050252 2005-05-11
K050068 2005-02-09
K042536 2005-01-19
K042346 2004-09-20
K041815 2004-07-29
K041204 2004-06-29
K040259 2004-04-22
K033998 2004-03-19
K040214 2004-02-25
K033296 2004-02-19
K032551 2004-02-19
K033349 2004-01-28
K033298 2003-12-12
K031330 2003-05-12
K013792 2001-12-11
K012992 2001-10-03
K011851 2001-07-11
K010419 2001-03-06
K003167 2000-11-08
K003244 2000-11-08
K002939 2000-10-06
K002751 2000-10-05
K002682 2000-09-13
K002477 2000-09-08
K002574 2000-09-06
K000126 2000-04-14
K993555 1999-11-19
K992238 1999-10-08
K992340 1999-10-08
K990966 1999-06-07
K973887 1998-01-08
K962603 1997-02-06

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of rainbow® DCI-dc3 SpCO® SpMet® SpO2 Adult Direct Connect Reusable Sensor
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Masimo Corporation 510(k) number 2015-10-28 Class II Finished device change control These sensors were manufactured with incompatible configurations. This could result in sensors that will provide either no readings or inaccurate readings for the SpCO and SpMet parameters. 3476 units total (3322 units in US) 2016-05-18

Recalls

10 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-02-15 Class II Material/Component Contamination Their is a potential that Oximeter may automatically power off and on resulting in loss of monitoring. 4978 units
2024-02-15 Class II Material/Component Contamination Their is a potential that Oximeter may automatically power off and on resulting in loss of monitoring. 21,723 units
2024-02-15 Class II Material/Component Contamination Their is a potential that Oximeter may automatically power off and on resulting in loss of monitoring. 443 units
2024-02-15 Class II Material/Component Contamination Their is a potential that Oximeter may automatically power off and on resulting in loss of monitoring. 65
2023-04-21 Class II Nonconforming Material/Component TC-I tip clip sensor may produce readings outside the accuracy specification. 138,926 units
2023-04-21 Class II Nonconforming Material/Component TC-I tip clip sensor may produce readings outside the accuracy specification. 123,745 units
2023-04-21 Class II Nonconforming Material/Component TC-I tip clip sensor may produce readings outside the accuracy specification. 86 units
2023-04-21 Class II Nonconforming Material/Component TC-I tip clip sensor may produce readings outside the accuracy specification. 443,799 units
2014-09-30 Class II Employee error Firm has identified a small number of Oximetry Cables with crossed-internal wires. The effect on performance when these wires are crossed is that when a low SpO2 value is measured, a high SpO2 value would be displayed on the monitoring dev 21,754 units (21,222) in the U.S. and Puerto Rico) 2016-03-28
2013-03-13 Class II Device Design Masimo has identified a very small number (0.02%) of Rad-8 devices with 20-pin patient cable connector that, when moved, can power off without the operator pressing the power button. 42,908 units 2015-06-10
2010-12-23 Not classified Process design Masimo Corporation is initiating a voluntary recall on the Pronto-7 rainbow 4D Resuable Sensor because when performing an SpHb measurement, the sensor may incorrectly read actual finger temperature. As a result, Pronto-7 Check Pulse CO-Oxi 497 2013-03-26
2006-02-02 Not classified Other Internal testing revealed that some of the sensors might not meet the accuracy specifications of : 2% for SpO2 and of: 3% for SpCO, due to the tolerance of one of the emitter LED’s used in the calculation ofSpO2 and SpCO. The SpO2 reading m 321 2008-06-17
2005-06-10 Not classified Other Speaker component failure resulting in ceasation of an audible alarm even though the condition continues that caused the alarm. 8,110 2008-06-17

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer