Trilogy 202
Trilogy 202 Ventilator, Russia
Who Else Makes It
Concentrated in Guangdong (46), Jiangsu (7), Beijing (5). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Tianjin Choice Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 12 |
| Taijia Medical Electronics (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| EMI (Dongguan) Asia Limited | Dongguan | Guangdong | Contract manufacturer | 9 |
| Wuhan Strong Electronics | Wuhan | Hubei | Contract manufacturer | 6 |
| Regent Electron Suzhou Co., Ltd. | Wujiang | Jiangsu | Contract manufacturer | 5 |
| Dongguan Ruibaolian Medical Science & Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 4 |
| Dongguan Kepler Special Cabling Company Limited | Dongguan | Guangdong | Contract manufacturer | 3 |
| Measurement Specialties Chengdu | Chengdu | Sichuan | Contract manufacturer | 3 |
| Beijing Kingst Commercial & Trade Co., Ltd. | Beijing | Beijing | Contract manufacturer | 2 |
| Suzhou Meccan Import and Export Corp. | Suzhou | Jiangsu | Contract manufacturer | 71 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
Showing 12 of 70. All 70 manufacturers in China registered for Oximeter
Record
| Listed by | Respironics Inc., United States |
|---|---|
| FDA product code | DQA |
| Device type | Oximeter |
| Device class | Class 2 |
| Regulation | 21 CFR 870.2700 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K093905 |
| Record published | 2018-02-16 |
| Record revised | 2021-03-04 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
| Storage | Storage environment humidity 15 to 95 % RH; Storage environment temperature -4 to 140 °F; Storage environment temperature -20 to 60 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Trilogy 202 Ventilator, Russia | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Unimed | Unimed Medical Supplies Inc | 2,838 |
| APK | APK Technology Co., Ltd. | 2,678 |
| ChoiceMMed | Beijing Choice Electronic Technology Co., Ltd. | 151 |
| Nellcor | Covidien LP | 138 |
| Nonin | Nonin Medical, Inc. | 129 |
| Orantech | Orantech Inc. | 97 |
| Med-link | Shenzhen MED-Link Electronics Tech Co., Ltd. | 93 |
| Welch Allyn, Inc. | Welch Allyn, Inc. | 66 |
| Medichoice | Owens & Minor Distribution, Inc. | 62 |
| Caremed | Shenzhen Caremed Medical Technology Co., Ltd. | 55 |
| Sensoronics | Sensoronics Incorporated | 53 |
| Virtuox | Healthcare Logistics Systems | 36 |
Showing 12 of 1,063. All products under Oximeter
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K972829 | 1997-10-28 |
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Philips Respironics, Inc. | 510(k) number | 2016-01-18 | Class II | Software design | Software Issue | 104,508 units | 2017-05-26 |
| Respironics Inc. | 510(k) number | 2014-02-11 | Class I | Component design/selection | Internal testing revealed a potentially defective component on the power management board that could affect the function of certain Trilogy Ventilators resulting in loss of therapy to patients. | 572 | 2015-04-17 |
| Respironics Inc. | 510(k) number | 2012-04-27 | Class I | Component design/selection | The specified Trilogy units are being recalled because of the potential for a faulty component in the power supply. | 173 | 2012-11-01 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.