LifeSignals
3 catalogue numbers from LP1253, listed by LifeSignals, Inc., United States, under Transmitters And Receivers, Physiological Signal, Radiofrequency. 11 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (5), Jiangsu (2), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Linxens Healthcare (Tianjin) Co., Ltd. | Jinnan District | Tianjin | Contract manufacturer | 7 |
| Dongguan CFE Electronic Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 2 |
| Chero Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 1 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Orantech Inc. | Shenzhen | Guangdong | Contract manufacturer | 40 |
| Suzhou Prosteri Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 20 |
| Avita (Wujiang) Co., Ltd. | Wujiang | Jiangsu | Contract manufacturer | 15 |
| Hangzhou VivaLNK Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Exporter | 4 |
Record
| Listed by | LifeSignals, Inc., United States |
|---|---|
| FDA product code | DRG |
| Device type | Transmitters And Receivers, Physiological Signal, Radiofrequency |
| Device class | Class 2 |
| Regulation | 21 CFR 870.2910 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| Record published | 2020-08-11 |
| Record revised | 2023-11-30 (version 4) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
| Storage | Special storage condition: For long-term storage of more than 30 days, maintain between 5 and 27 Degrees Celsius; Storage environment humidity 10 to 90 % RH; Storage environment temperature 0 to 45 °C; Handling environment humidity 10 to 90 % RH; Handling environment temperature 0 to 45 °C |
| Packaging | Small box of 25, big box of 8 |
| Distribution end date | 2023-11-01 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| LP1253 | In distribution | |
| LP1251 | In distribution | |
| LP1250 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Vital Sync | Covidien LP | 29 |
| Transmitters And Receivers, Physiological Signal, Radiofrequency | Nihon Kohden Corp. | 22 |
| LifeSync | LifeSync Corporation | 18 |
| Surveyor Patient Cable | Mortara Instrument, Inc. | 18 |
| Isansys | Isansys Lifecare, Ltd. | 15 |
| ZephyrLIFE Home | Zephyr Technology Corporation | 11 |
| Transmitters And Receivers, Physiological Signal, Radiofrequency | Nihon Kohden America, Inc. | 9 |
| InTouch Health | Intouch Health, Inc. | 7 |
| UbiqVue | LifeSignals, Inc. | 6 |
| X12+ | Mortara Instrument, Inc. | 5 |
| Welch Allyn, Inc. | Welch Allyn, Inc. | 5 |
| Ezypro ECG Recorder | Sigknow Biomedical Co., Ltd. | 3 |
Showing 12 of 211. All products under Transmitters And Receivers, Physiological Signal, Radiofrequency
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K261569 | 2026-07-09 |
| K242018 | 2024-11-12 |
| K202868 | 2021-07-21 |
| K200690 | 2020-07-15 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.