Telemetry Transmitter
Catalogue number iT20, listed by Edan Instruments, Inc., China, under Transmitters And Receivers, Physiological Signal, Radiofrequency. 11 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (5), Jiangsu (2), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Linxens Healthcare (Tianjin) Co., Ltd. | Jinnan District | Tianjin | Contract manufacturer | 7 |
| Dongguan CFE Electronic Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 2 |
| Chero Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 1 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Orantech Inc. | Shenzhen | Guangdong | Contract manufacturer | 40 |
| Suzhou Prosteri Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 20 |
| Avita (Wujiang) Co., Ltd. | Wujiang | Jiangsu | Contract manufacturer | 15 |
| Hangzhou VivaLNK Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Exporter | 4 |
Record
| Listed by | Edan Instruments, Inc., China |
|---|---|
| FDA product code | DRG |
| Device type | Transmitters And Receivers, Physiological Signal, Radiofrequency |
| Device class | Class 2 |
| Regulation | 21 CFR 870.2910 |
| Establishment | Contract manufacturer, Manufacturer |
| 510(k) | K161056 |
| Record published | 2017-02-22 |
| Record revised | 2021-11-10 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Packaging | Pack of 4 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| iT20 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Vital Sync | Covidien LP | 29 |
| Transmitters And Receivers, Physiological Signal, Radiofrequency | Nihon Kohden Corp. | 22 |
| LifeSync | LifeSync Corporation | 18 |
| Surveyor Patient Cable | Mortara Instrument, Inc. | 18 |
| Isansys | Isansys Lifecare, Ltd. | 15 |
| ZephyrLIFE Home | Zephyr Technology Corporation | 11 |
| Transmitters And Receivers, Physiological Signal, Radiofrequency | Nihon Kohden America, Inc. | 9 |
| InTouch Health | Intouch Health, Inc. | 7 |
| UbiqVue | LifeSignals, Inc. | 6 |
| X12+ | Mortara Instrument, Inc. | 5 |
| Welch Allyn, Inc. | Welch Allyn, Inc. | 5 |
| Ezypro ECG Recorder | Sigknow Biomedical Co., Ltd. | 3 |
Showing 12 of 211. All products under Transmitters And Receivers, Physiological Signal, Radiofrequency
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Edan Diagnostics, Inc. | 510(k) number | 2025-10-24 | Class II | Device Design | As a result of receiving an FDA It Has Come to Our Attention Letter (IHCTOA Letter) regarding potential cybersecurity issues with various of the firm device. | 1457 | |
| Edan Diagnostics, Inc. | 510(k) number | 2017-11-17 | Class II | No Marketing Application | Firm became aware that it distributed 7 units in the U.S. that included a function that had not been cleared by U.S. FDA. | 7 units | 2022-09-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.