Triple Pressure Kit
2 catalogue numbers from 042951705F, listed by Argon Medical Devices, Inc., United States, under Transducer, Blood-Pressure, Extravascular. 7 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (5), Zhejiang (1), Shandong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Bioxin Medical Co., Ltd. | Weihai | Shandong | Contract manufacturer | 8 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| Orantech Inc. | Shenzhen | Guangdong | Contract manufacturer | 40 |
| Zhejiang Haisheng Medical Device Co., Ltd. | Shaoxing | Zhejiang | Contract manufacturer | 21 |
| Unimed Medical Supplies Inc | Shenzhen | Guangdong | Contract manufacturer | 15 |
| Shenzhen Antmed Co., Ltd. | Dongguan | Guangdong | Manufacturer | 4 |
Record
| Listed by | Argon Medical Devices, Inc., United States |
|---|---|
| FDA product code | DRS |
| Device type | Transducer, Blood-Pressure, Extravascular |
| Device class | Class 2 |
| Regulation | 21 CFR 870.2850 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer |
| Record published | 2016-09-16 |
| Record revised | 2026-05-11 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Packaging | Box of 5, box of 10 |
| Distribution end date | 2024-12-10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 042951705F | Withdrawn | |
| 042942601B | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| ICU Medical | ICU Medical, Inc | 381 |
| Medex | ICU Medical, Inc | 225 |
| Biotrans™ Pressure Monitoring Kits | Bioptimal International Pte. Ltd. | 134 |
| Transpac™ | ICU Medical, Inc | 117 |
| Antmed | Shenzhen Antmed Co., Ltd. | 96 |
| Namic | Navilyst Medical, Inc. | 60 |
| Namic | Medline Industries, Inc. | 58 |
| Transpac™/Transtar™ | ICU Medical, Inc | 58 |
| Merit Medical® | Argon Critical Care Systems Singapore PTE. Ltd. | 28 |
| Centurion | Centurion Medical Products Corporation | 23 |
| Transducer, Blood-Pressure, Extravascular | Utah Medical Products, Inc. | 22 |
| Deltran | Utah Medical Products, Inc. | 22 |
Showing 12 of 145. All products under Transducer, Blood-Pressure, Extravascular
Recalls
9 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2018-10-16 | Class II | Equipment maintenance | The seal formed on the edge of the pouch may be incomplete, which could result in a loss of sterility to the product. | Total number in recall for all products in dist: 49,130 unit | 2021-06-15 |
| 2018-10-16 | Class II | Equipment maintenance | The seal formed on the edge of the pouch may be incomplete, which could result in a loss of sterility to the product. | Total number in recall for all products in dist: 49,130 unit | 2021-06-15 |
| 2018-10-16 | Class II | Equipment maintenance | The seal formed on the edge of the pouch may be incomplete, which could result in a loss of sterility to the product. | Total number in recall for all products in dist: 49,130 unit | 2021-06-15 |
| 2018-10-16 | Class II | Equipment maintenance | The seal formed on the edge of the pouch may be incomplete, which could result in a loss of sterility to the product. | Total number in recall for all products in dist: 49,130 unit | 2021-06-15 |
| 2018-10-16 | Class II | Equipment maintenance | The seal formed on the edge of the pouch may be incomplete, which could result in a loss of sterility to the product. | Total number in recall for all products in dist: 49,130 unit | 2021-06-15 |
| 2018-10-16 | Class II | Equipment maintenance | The seal formed on the edge of the pouch may be incomplete, which could result in a loss of sterility to the product. | Total number in recall for all products in dist: 49,130 unit | 2021-06-15 |
| 2018-10-16 | Class II | Equipment maintenance | The seal formed on the edge of the pouch may be incomplete, which could result in a loss of sterility to the product. | Total number in recall for all products in dist: 49,130 unit | 2021-06-15 |
| 2018-10-16 | Class II | Equipment maintenance | The seal formed on the edge of the pouch may be incomplete, which could result in a loss of sterility to the product. | Total number in recall for all products in dist: 49,130 unit | 2021-06-15 |
| 2018-10-16 | Class II | Equipment maintenance | The seal formed on the edge of the pouch may be incomplete, which could result in a loss of sterility to the product. | Total number in recall for all products in dist: 49,130 unit | 2021-06-15 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.