Red Dot™
3M™ Red Dot™ Neonatal, Pre-Wired, Radiolucent Monitoring Electrode with Clear Tape 2269T, 3/BG 10BG/BX 10BX/CASE
Who Else Makes It
Concentrated in Guangdong (12), Jiangsu (6), Zhejiang (6). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| China Qingdao Bright Medical Manufacturing Co., Ltd. | Qingdao | Shandong | Contract manufacturer | 8 |
| Linxens Healthcare (Tianjin) Co., Ltd. | Jinnan District | Tianjin | Contract manufacturer | 7 |
| Dongguan Ruibaolian Medical Science & Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 4 |
| Shanghai Yuechen Medical Supply Co..ltd. | Shanghai | Shanghai | Contract manufacturer | 1 |
| Boen Healthcare Co., Ltd. | Suzhou | Jiangsu | Specification developer | 263 |
| Hospital & Homecare IMP. & EXP. Co., Ltd. | Nanjing | Jiangsu | Contract manufacturer | 179 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Huzhou Junda Industry Co., Ltd. | Anji | Zhejiang | Contract manufacturer | 129 |
| Zhejiang Mediunion Healthcare Group Co., Ltd. | Ningbo | Zhejiang | Contract manufacturer | 105 |
| Ningbo Greetmed Medical Instruments Co., Ltd. | Ningbo | Zhejiang | Specification developer | 75 |
| Shanghai NEO-Medical Import & Export Co., Ltd. | Shanghai | Shanghai | Exporter | 59 |
| Ningbo Chibanda IMP &EXP Co., Ltd. | Ningbo | Zhejiang | Manufacturer | 59 |
Showing 12 of 33. All 33 manufacturers in China registered for Electrode, Electrocardiograph
Record
| Listed by | 3M Company, United States |
|---|---|
| FDA product code | DRX |
| Device type | Electrode, Electrocardiograph |
| Device class | Class 2 |
| Regulation | 21 CFR 870.2360 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2016-09-24 |
| Record revised | 2024-08-16 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Packaging | Box of 20, box of 200, box of 100, box of 40, box of 4, carton of 10 |
| Distribution end date | 2024-08-15 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 2270-5 | 5 | In distribution | |
| 2360 | 100 | In distribution | |
| 9641 | 50 | In distribution | |
| 2289PA | 5 | In distribution | |
| 2237 | 50 | In distribution | |
| 2660-3 | 3 | In distribution | |
| 2330 | 100 | In distribution | |
| 2570 | 50 | In distribution | |
| 9650 | 10 | In distribution | |
| 2259-3 | 3 | In distribution | |
| 9642 | 50 | In distribution | |
| 2560 | 50 | In distribution | |
| 2570-5 | 5 | In distribution | |
| 2238-5 | 5 | In distribution | |
| 2230 | 50 | In distribution | |
| 2271-50 | 50 | In distribution | |
| 2248-50 | 50 | In distribution | |
| 2271-5 | 5 | In distribution | |
| 2236 | In distribution | ||
| 9640 | 50 | In distribution | |
| 2249-50 | 50 | In distribution | |
| 2570-3 | 3 | In distribution | |
| 2259-50 | 50 | In distribution | |
| 2270-50 | 50 | In distribution | |
| 2255-50 | 50 | In distribution | |
| 2280 | 300 | In distribution | |
| 2256-50 | 50 | In distribution | |
| 2660-5 | 5 | In distribution | |
| 2282 | 300 | In distribution | |
| 2245-50 | 50 | In distribution | |
| 2670-5 | 5 | In distribution | |
| 2269T | 3 | In distribution | |
| 2670-3 | 3 | In distribution | |
| 2284 | 300 | In distribution | |
| 2238 | 50 | In distribution | |
| 2235 | 50 | In distribution | |
| 2289PAL | 5 | In distribution | |
| 2268-3 | 3 | In distribution | |
| 2283 | 300 | In distribution | |
| 2231 | 50 | In distribution | |
| 2282L | 300 | In distribution | |
| 2289T | 3 | In distribution | |
| 2239 | 50 | In distribution | |
| 2236 | 36 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| APK | APK Technology Co., Ltd. | 113 |
| Electrode, Electrocardiograph | Fiab SPA | 109 |
| Swaromed | Tyrolmed GmbH | 93 |
| MediMax Tech | Medimax Tech Inc. | 91 |
| Kendall | Cardinal Health | 91 |
| Medline | Medline Industries, Inc. | 78 |
| AMC | LifeSync Corporation | 74 |
| Kendall | Cardinal Health 200, LLC | 73 |
| Ambu WhiteSensor | Medico Electrodes International Ltd | 51 |
| Z-Brand™ | Graphic Controls Acquisition Corporation | 48 |
| S&W | Leonhard Lang Gmbh | 47 |
| Vermed | Graphic Controls Acquisition Corporation | 45 |
Showing 12 of 337. All products under Electrode, Electrocardiograph
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K974445 | 1998-07-26 |
| K970796 | 1997-04-09 |
| K902080 | 1990-07-18 |
| K896155 | 1989-12-13 |
| K821438 | 1982-05-25 |
Recalls
6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2021-10-06 | Class II | Process control | Potential for breakage of the ECG electrode carbon stud from the eyelet. | 2,081,000 electrodes | 2024-01-17 |
| 2020-09-15 | Class II | Process control | Corrosion could cause performance failures in the product. | 720,000 | 2022-02-01 |
| 2020-09-15 | Class II | Process control | Corrosion could cause performance failures in the product. | 10,145,050 units | 2022-02-01 |
| 2020-09-15 | Class II | Process control | Corrosion could cause performance failures in the product. | 1,572,000 units | 2022-02-01 |
| 2020-09-15 | Class II | Process control | Corrosion could cause performance failures in the product. | 287,200 units | 2022-02-01 |
| 2020-09-15 | Class II | Process control | Corrosion could cause performance failures in the product. | 156,600 units | 2022-02-01 |
| 2010-07-27 | Not classified | Process control | The sensing element of the 3M Red Dot Monitoring Electrode, Catalog # 2560 and Novaplus Universal Monitoring Electrode #V2560 may have corrosion. In an emergency situation where defibrillation is necessary and electrodes are already in use | 11,063 cases (20 pouches/case, 50 electrodes/pouch) | 2012-04-19 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.