Caremed
Caremed Patient Cable and Leadwires
Who Else Makes It
Concentrated in Guangdong (18), Jiangsu (1), Zhejiang (1). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Ningbo Xinwell Medical Technology Co., Ltd. | Cixi | Zhejiang | Contract manufacturer | 12 |
| APK Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 6 |
| ABA Medical Technology Co Ltd | Guang Dong | Guangdong | Contract manufacturer | 6 |
| Beijing Rongrui Century Science Technology Co., Ltd. | Beijing | Beijing | Contract manufacturer | 4 |
| Dongguan Rongrui-Century Science&Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 4 |
| Dongguan Ruibaolian Medical Science & Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 4 |
| Dongguan Kepler Special Cabling Company Limited | Dongguan | Guangdong | Contract manufacturer | 3 |
| Palconn Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 2 |
| Shenzhen Redy-MED Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 2 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
Showing 12 of 22. All 22 manufacturers in China registered for Cable, Transducer And Electrode, Patient, (Including Connector)
Record
| Listed by | Shenzhen Caremed Medical Technology Co., Ltd., China |
|---|---|
| FDA product code | DSA |
| Device type | Cable, Transducer And Electrode, Patient, (Including Connector) |
| Device class | Class 2 |
| Regulation | 21 CFR 870.2900 |
| Establishment | Contract manufacturer, Manufacturer |
| 510(k) | K153188 |
| Record published | 2026-07-09 |
| Record revised | 2024-06-06 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
| Distribution end date | 2019-11-01 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| KM-PA01060G | In distribution | |
| 2585P | In distribution | |
| LSI-ECGL40 | In distribution | |
| KM-PA01048R | In distribution | |
| KM-PA01048B | In distribution | |
| KM-PA050540RG | In distribution | |
| KM-82060 | In distribution | |
| MQB5-90S | In distribution | |
| ED5R-90S-A | In distribution | |
| KM-PA01048G | In distribution | |
| KM-82096 | In distribution | |
| KM-PA01060R | In distribution | |
| E10R-SH1-N | In distribution | |
| EK10R-SH1-PA | In distribution | |
| KM-PA02036G | In distribution | |
| cable | In distribution | |
| MQ-2586 | In distribution | |
| E10R-MQ | In distribution | |
| MQ10-LN | In distribution | |
| LSI-ECGL30 | In distribution | |
| KM-82060/E | In distribution | |
| KM-PA051348TC | In distribution | |
| LSI-ECGL24 | In distribution | |
| PWC10-LB-A | Withdrawn | |
| EHPU385-A | Withdrawn | |
| EHPU585-A | Withdrawn | |
| AD-BA-10 | Withdrawn | |
| EHP5R-90P-A | Withdrawn | |
| EHP3R-90P-A | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Unimed | Unimed Medical Supplies Inc | 5,928 |
| AMC | LifeSync Corporation | 1,058 |
| Fogg System Company, Inc. | Fogg System Company, Inc. | 693 |
| Multi-Link™ | AirLife Finland Oy | 611 |
| Cable, Transducer And Electrode, Patient, (Including Connector) | ConMed Corporation | 284 |
| Maguire | Maguire Enterprises, Inc. | 193 |
| MediChoice | Owens & Minor Distribution, Inc. | 160 |
| Vermed | Graphic Controls Acquisition Corporation | 159 |
| Vital Signs™ | AirLife Finland Oy | 136 |
| Multi-Link™ | Carefusion Finland 320 Oy | 136 |
| Med-link | Shenzhen MED-Link Electronics Tech Co., Ltd. | 129 |
| Conmed | ConMed Corporation | 106 |
Showing 12 of 1,260. All products under Cable, Transducer And Electrode, Patient, (Including Connector)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K153188 | 2016-10-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.