Safety Adapter

The ADAP 1 is designed to interface between the recessed pin connectors used with Remington's cable models S-101-97, S-201-97, and FL-601-97, and the old models of external pulse generators…

Registry build 21.09.26

The ADAP 1 is designed to interface between the recessed pin connectors used with Remington’s cable models S-101-97, S-201-97, and FL-601-97, and the old models of external pulse generators (EPG) [old model is the acceptance of exposed 2mm pins]. Also, ADAP I is designed to be used with pacing system analyzers that have sockets that accept 2mm pins and 31.25mm separation between pins.

22manufacturers in China registered for this device type
4catalogue numbers in this listing
2510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Guangdong (18), Jiangsu (1), Zhejiang (1). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DSA
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Ningbo Xinwell Medical Technology Co., Ltd. Cixi Zhejiang Contract manufacturer 12
APK Technology Co., Ltd. Shenzhen Guangdong Contract manufacturer 6
ABA Medical Technology Co Ltd Guang Dong Guangdong Contract manufacturer 6
Beijing Rongrui Century Science Technology Co., Ltd. Beijing Beijing Contract manufacturer 4
Dongguan Rongrui-Century Science&Technology Co., Ltd. Dongguan Guangdong Contract manufacturer 4
Dongguan Ruibaolian Medical Science & Technology Co., Ltd. Dongguan Guangdong Contract manufacturer 4
Dongguan Kepler Special Cabling Company Limited Dongguan Guangdong Contract manufacturer 3
Palconn Technology Co., Ltd. Shenzhen Guangdong Contract manufacturer 2
Shenzhen Redy-MED Technology Co., Ltd. Shenzhen Guangdong Contract manufacturer 2
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56

Showing 12 of 22. All 22 manufacturers in China registered for Cable, Transducer And Electrode, Patient, (Including Connector)

Record

Regulatory record for Safety Adapter
Listed by Remington Medical, Inc., United States
FDA product code DSA
Device type Cable, Transducer And Electrode, Patient, (Including Connector)
Device class Class 2
Regulation 21 CFR 870.2900
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
Record published 2016-09-21
Record revised 2018-11-06 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number, manufacturing date
Packaging Shipping carton of 25
Sizes Length 254000000000000 Femtometer; area/surface area 15.204 Square inch

Catalogue Numbers

Catalogue numbers for Safety Adapter
Catalogue number Size Status
ADAP II Length 254000000000000 Femtometer In distribution
ADAP-2RL Length 254000000000000 Femtometer In distribution
ADAP I Area/Surface Area 15.204 Square inch In distribution
ADAP-2R Length 254000000000000 Femtometer In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Unimed Unimed Medical Supplies Inc 5,928
AMC LifeSync Corporation 1,058
Fogg System Company, Inc. Fogg System Company, Inc. 693
Multi-Link™ AirLife Finland Oy 611
Cable, Transducer And Electrode, Patient, (Including Connector) ConMed Corporation 284
Maguire Maguire Enterprises, Inc. 193
MediChoice Owens & Minor Distribution, Inc. 160
Vermed Graphic Controls Acquisition Corporation 159
Vital Signs™ AirLife Finland Oy 136
Multi-Link™ Carefusion Finland 320 Oy 136
Med-link Shenzhen MED-Link Electronics Tech Co., Ltd. 129
Conmed ConMed Corporation 106

Showing 12 of 1,260. All products under Cable, Transducer And Electrode, Patient, (Including Connector)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K971968 1997-07-23
K922009 1993-02-25

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2014-03-05 Class II Labeling Change Control Remington Medical discovered an error on the FL-601-97 IFU; part number IFU-RM-0154. Specifically, the polarity for the black chuck in the picture is wrong. It shows (+), but should show (-). 41,499 cables 2018-04-09
2010-05-19 Not classified Process design The Safe Connect component may separate from the cable, causing the cable to become unplugged from the EPG. 1488 units 2010-11-29

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer