Acist Navvus® Catheter

Navvus Catheter is a pressure-sensing catheter used with the ACIST RXi System to obtain intravascular pressure measurements. The measurements support assessment of coronary and peripheral…

Registry build 21.09.26

Navvus Catheter is a pressure-sensing catheter used with the ACIST RXi System to obtain intravascular pressure measurements. The measurements support assessment of coronary and peripheral artery disease in catheterization and cardiovascular laboratories.

An optical pressure sensor at the end of a fiber optic is integrated into a monorail catheter. The catheter carries the measured pressure signal to the RXi system, which converts the data into physiological measurements such as fractional flow reserve.

Listed Item

Navvus Catheter, p/n 701481-010

Catheter Placement

The catheter is designed to fit within a percutaneous guiding catheter for passage through a vessel. It is a single-patient sensing device used as the measurement component of the compatible RXi system.

4manufacturers in China registered for this device type
3catalogue numbers in this listing
2510(k) clearances naming this product code

Who Else Makes It

Concentrated in Shanghai (1), Guangdong (1), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code DXO
Manufacturer City Province Registered as Device types
Amphenol Alden Products Company Shenzhen Guangdong Contract manufacturer 24
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Suzhou Prosteri Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 20
Beijing Bywave Sensing Medical Technology Co., Ltd. Beijing Beijing Manufacturer 2

Record

Regulatory record for Acist Navvus® Catheter
Listed by Acist Medical Systems, Inc., United States
FDA product code DXO
Device type Transducer, Pressure, Catheter Tip
Device class Class 2
Regulation 21 CFR 870.2870
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K132474
Record published 2017-08-15
Record revised 2019-10-18 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging Shelf box, inner box of 5, pack of 5
Distribution end date 2019-04-10

Catalogue Numbers

Catalogue numbers for Acist Navvus® Catheter
Catalogue number Size Status
014667 Working Length: 150 Centimeter In distribution
014667 Working Length: 150 Centimeter Withdrawn
014667 Working Length: 150 Centimeter Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Truwave Edwards Lifesciences Technology Sarl 456
OptoMonitor 3 Opsens Inc. 73
Truwave, Vamp Edwards Lifesciences Technology Sarl 45
Truwave, Vamp Plus Edwards Lifesciences Technology Sarl 24
PX1800 → Truwave Cables Edwards Lifesciences Technology Sarl 22
Truwave, Vamp JR Edwards Lifesciences Technology Sarl 12
Truwave Cables Edwards Lifesciences Technology Sarl 7
TruWave, Vamp Plus Becton, Dickinson AND Company 5
TruWave Becton, Dickinson AND Company 4
Comet Boston Scientific Corporation 4
Medline Industries, Inc. Medline Industries, Inc. 4
Pressure Tubing Edwards Lifesciences Technology Sarl 3

Showing 12 of 63. All products under Transducer, Pressure, Catheter Tip

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K233904 2024-07-17
K132474 2014-01-30

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer