Telemetry Transmitter

2 catalogue numbers from TD-60, listed by Shenzhen Mindray BIO-Medical Electronics Co., Ltd., China, under System, Network And Communication, Physiological Monitors. 4 manufacturers in China are registered for this product code.

Registry build 21.09.26
4manufacturers in China registered for this device type
2catalogue numbers in this listing
7510(k) clearances naming this product code

Who Else Makes It

All of them in Guangdong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code MSX
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Orantech Inc. Shenzhen Guangdong Contract manufacturer 40

Record

Regulatory record for Telemetry Transmitter
Listed by Shenzhen Mindray BIO-Medical Electronics Co., Ltd., China
FDA product code MSX
Device type System, Network And Communication, Physiological Monitors
Device class Class 2
Regulation 21 CFR 870.2300
Establishment Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K150632
Record published 2015-10-23
Record revised 2020-02-06 (version 4)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Telemetry Transmitter
Catalogue number Size Status
TD-60 In distribution
608M In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Messenger Spok Inc. 9
eCareManager Visicu, Inc. 8
Engage Medical Device Alarm Notification System (Emdan) Stryker GmbH 8
BeneVision Central Monitoring System Shenzhen Mindray BIO-Medical Electronics Co., Ltd. 7
Xhibit Spacelabs Healthcare (Washington), Inc 4
IntelliVue XDS Software Philips Medizin Systeme Böblingen GmbH 4
Ascom Ascom Sweden AB 3
Spacelabs Healthcare Spacelabs Healthcare (Washington), Inc 3
Patient SafetyNet Console Masimo Corporation 3
System, Network And Communication, Physiological Monitors Philips Medical Systems Hsg 3
RescueNet 12-Lead Zoll Medical Corporation 2
Current Health Wearable Monnitoring System Current Health Ltd 2

Showing 12 of 165. All products under System, Network And Communication, Physiological Monitors

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K242728 2025-07-31
K220058 2022-06-01
K193391 2020-05-21
K183238 2019-03-13
K162607 2017-04-20
K150632 2015-07-06
K080192 2008-04-03

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Telemetry Transmitter
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Mindray DS USA, Inc. 510(k) number 2017-07-14 Class II Component design/selection A damaged circuit board in the battery charger can cause the battery to overcharge and the battery case to swell and separate. 203 2018-12-17

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker