ECG Cable for Seer 1000

The cable is intended to be used to conduct electrical signals from a patient's heart, via an electrode attached to the surface of the chest/limbs, to an electrocardiograph (ECG) machine (…

Registry build 21.09.26

The cable is intended to be used to conduct electrical signals from a patient’s heart, via an electrode attached to the surface of the chest/limbs, to an electrocardiograph (ECG) machine ( SEER 1000 recorder).

4manufacturers in China registered for this device type
12catalogue numbers in this listing
4510(k) clearances naming this product code

Who Else Makes It

Concentrated in Guangdong (2), Shanghai (1), Beijing (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code MWJ
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Philips (China) Investment Co., Ltd. Philips Healthcare – Shanghai CDC Shanghai Shanghai Specification developer 6
DM Systems (Beijing) Co., Ltd. Beijing Beijing Manufacturer 1

Record

Regulatory record for ECG Cable for Seer 1000
Listed by Getemed Medizin- UND Informationstechnik AG, Germany
FDA product code MWJ
Device type Electrocardiograph, Ambulatory (Without Analysis)
Device class Class 2
Regulation 21 CFR 870.2800
Establishment Manufacturer, Exporter
510(k) K130785
Record published 2019-09-12
Record revised 2024-06-06 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Latex Contains natural rubber latex
Label carries manufacturing date, serial number
Storage Special storage condition: Keep Dry; Handling environment humidity 0 to 90 % RH; Handling environment temperature -25 to 70 °C

Catalogue Numbers

Catalogue numbers for ECG Cable for Seer 1000
Catalogue number Size Status
7 Leads, 75 cm, AHA Color Code In distribution
5 Leads, 75 cm, IEC Color Code In distribution
7 Leads, 105 cm, IEC Color Code In distribution
3 Leads, 75 cm, AHA Color Code In distribution
7 Leads, 105 cm, AHA Color Code In distribution
5 Leads, 105 cm, IEC Color Code In distribution
5 Leads, 105 cm, AHA Color Code In distribution
7 Leads, 75 cm, IEC Color Code In distribution
5 Leads, 75 cm, AHA Color Code In distribution
3 Leads, 105 cm, IEC Color Code In distribution
3 Leads, 75 cm, IEC Color Code In distribution
3 Leads, 105 cm, AHA Color Code In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Spacelabs Healthcare Spacelabs Healthcare (Washington), Inc 60
Welch Allyn, Inc. Welch Allyn, Inc. 58
Norav NR Series Norav Medical Inc. 56
Eclipse Pro Spacelabs Healthcare (Washington), Inc 25
Seer 1000 Getemed Medizin- UND Informationstechnik AG 15
Seer 1000 ECG Cable Getemed Medizin- UND Informationstechnik AG 12
Seer Suzuken Co., Ltd. 12
H12+ Mortara Instrument, Inc. 10
Lifecard Spacelabs Healthcare (Washington), Inc 10
H3+ Patient Cable Mortara Instrument, Inc. 10
Spiderview Microport CRM SRL 9
ECG Cable for CM 3000-12 BT / Seer 12 Getemed Medizin- UND Informationstechnik AG 7

Showing 12 of 107. All products under Electrocardiograph, Ambulatory (Without Analysis)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K130785 2013-07-26
K122272 2013-03-28
K063042 2007-05-30
K051686 2005-07-14

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer