Ultra Iabp Catheter Kit

The Insightra Intra Aortic Balloon Catheter Kit is used in conjunction with an intra-aortic balloon pumping circuit for the emergency treatment of patients in cardiogenic shock. This…

Registry build 21.09.26

The Insightra Intra Aortic Balloon Catheter Kit is used in conjunction with an intra-aortic balloon pumping circuit for the emergency treatment of patients in cardiogenic shock. This condition occurs in patients post acute myocardial infarction, or with reduced cardiac output post open-heart surgery.

1manufacturer
3catalogue numbers in this listing
1510(k) clearance
1recall

Who Else Makes It

Registered in Guangdong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code DSP
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77

Record

Regulatory record for Ultra Iabp Catheter Kit
Listed by Insightra Medical, Inc., United States
FDA product code DSP
Device type System, Balloon, Intra-Aortic And Control
Device class Class 2
Regulation 21 CFR 870.3535
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K082746
Record published 2015-03-17
Record revised 2020-07-20 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Packaging Shipper box implant of 5, shipper box of 5, pack of 5
Sizes Catheter gauge 7 Fr; total volume 30 to 40 ml

Catalogue Numbers

Catalogue numbers for Ultra Iabp Catheter Kit
Catalogue number Size Status
IMU7F-30 Catheter Gauge 7 Fr In distribution
IMU7F-40 Total Volume 40 ml In distribution
IMU7F-35 Total Volume 35 ml In distribution

Same Product Code

Showing 12 of 268. All products under System, Balloon, Intra-Aortic And Control

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K082746 2009-01-12

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Ultra Iabp Catheter Kit
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Insightra Medical, Inc. 510(k) number 2025-07-19 Class II No Marketing Application Device contains indications for use and device compatibility claims that have not be reviewed and approved for safety and effectiveness by the FDA. Instructions for use are not consistent with product training. 24227 units 2026-03-18

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer