Tornado

Tornado Embolization Microcoil

Registry build 21.09.26
6manufacturers in China registered for this device type
111catalogue numbers in this listing
13510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (4), Guangdong (1), Shanghai (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code KRD
Manufacturer City Province Registered as Device types
Amphenol Alden Products Company Shenzhen Guangdong Contract manufacturer 24
Suzhou Prosteri Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 20
Canyon Medical Inc. Nanjing Jiangsu Manufacturer 4
Suzhou Hengrui Hongyuan Medical Co., Ltd. Suzhou Jiangsu Manufacturer 3
Microport Neurotech (Shanghai) Co., Ltd. Shanghai Shanghai Manufacturer 2
Suzhou Haowei Medical Technology Co., Ltd. Suzhou Jiangsu Manufacturer 1

Record

Regulatory record for Tornado
Listed by Cook Incorporated, United States
FDA product code KRD
Device type Device, Vascular, For Promoting Embolization
Device class Class 2
Regulation 21 CFR 870.3300
Establishment Contract manufacturer, Contract steriliser, Specification developer, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2018-09-04
Record revised 2021-02-05 (version 3)

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Storage Special storage condition: Store in dark, dry, cool place.

Catalogue Numbers

Catalogue numbers for Tornado
Catalogue number Size Status
G47547 In distribution
G11059 In distribution
G08356 In distribution
G47425 In distribution
G08259 In distribution
G12924 In distribution
G47541 In distribution
G09952 In distribution
G10425 In distribution
G10420 In distribution
G10417 In distribution
G11051 In distribution
G47423 In distribution
G47430 In distribution
G47432 In distribution
G09953 In distribution
G11058 In distribution
G47524 In distribution
G47431 In distribution
G08939 In distribution
G47525 In distribution
G08261 In distribution
G09218 In distribution
G47550 In distribution
G09949 In distribution
G09948 In distribution
G47528 In distribution
G10427 In distribution
G47416 In distribution
G47522 In distribution
G10411 In distribution
G47530 In distribution
G47434 In distribution
G47527 In distribution
G13210 In distribution
G10416 In distribution
G10412 In distribution
G47424 In distribution
G10418 In distribution
G47415 In distribution
G11052 In distribution
G47417 In distribution
G47521 In distribution
G47426 In distribution
G10414 In distribution
G13366 In distribution
G47538 In distribution
G11055 In distribution
G08357 In distribution
G09947 In distribution
G47520 In distribution
G11053 In distribution
G10413 In distribution
G47523 In distribution
G09951 In distribution
G13106 In distribution
G47419 In distribution
G47519 In distribution
G47549 In distribution
G47531 In distribution
G47427 In distribution
G47421 In distribution
G47517 In distribution
G10419 In distribution
G47533 In distribution
G13207 In distribution
G10422 In distribution
G47548 In distribution
G10415 In distribution
G11065 In distribution
G13108 In distribution
G09217 In distribution
G09944 In distribution
G13346 In distribution
G47536 In distribution
G11056 In distribution
G13105 In distribution
G13109 In distribution
G47532 In distribution
G47429 In distribution
G47420 In distribution
G47535 In distribution
G47539 In distribution
G10428 In distribution
G47546 In distribution
G47540 In distribution
G13107 In distribution
G47534 In distribution
G10421 In distribution
G10424 In distribution
G47422 In distribution
G47428 In distribution
G11054 In distribution
G11064 In distribution
G47418 In distribution
G09837 In distribution
G47537 In distribution
G10426 In distribution
G11057 In distribution
G47544 In distribution
G09945 In distribution
G47545 In distribution
G09946 In distribution
G09216 In distribution
G47542 In distribution
G09215 In distribution
G09950 In distribution
G47529 In distribution
G47518 In distribution
G11061 In distribution
G13209 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prestige Coil System Balt USA, LLC 339
Axium™ Detachable Coil System Micro Therapeutics, Inc. 279
Optima Coil System Balt USA, LLC 255
AxiumTM Micro Therapeutics, Inc. 255
Avenir Shanghai Wallaby Medical Technologies Co., Inc. 184
MReye Cook Incorporated 167
Axium™ Prime Detachable Coil System Micro Therapeutics, Inc. 162
Nester Cook Incorporated 160
Axium Micro Therapeutics, Inc. 146
ConcertoTM Micro Therapeutics, Inc. 133
V-Trak MicroVention, Inc. 105
HydroFrame 10 Advanced MicroVention, Inc. 104

Showing 12 of 158. All products under Device, Vascular, For Promoting Embolization

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K160219 2016-08-03
K153778 2016-05-19
K150931 2015-12-18
K150964 2015-12-18
K151676 2015-07-22
K123712 2013-01-03
K090624 2009-04-02
K063619 2006-12-20
K052834 2005-11-23
K993455 2000-01-11
K992121 1999-12-20
K940189 1994-11-28
K940982 1994-10-14

Recalls Naming This Product

2 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of Tornado
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Cook Incorporated UDI-DI 2025-04-17 Class II Process control Cook Medical identified that devices from the affected device lots may contain the incorrectly sized embolization coil. 2952 units
Cook Incorporated UDI-DI 2022-05-05 Class II Under Investigation by firm The loading cartridges included with these devices may contain a small, unintended, stainless-steel cannula. 106,033

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2022-05-05 Class II Under Investigation by firm The loading cartridges included with these devices may contain a small, unintended, stainless-steel cannula. 106,033
2022-05-05 Class II Under Investigation by firm The loading cartridges included with these devices may contain a small, unintended, stainless-steel cannula. 106,033
2005-09-26 Not classified Other The coil is 20 centimeters in length, but the label states the length is 20 millimeters. 242 2006-01-10

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P780011 1988-01-29 MINI BALLOON Bd Becton Dickinson Vacutainer Systems Preanalytic

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer