Check-Flo
Check-Flo Hemostasis Assembly
Who Else Makes It
Concentrated in Jiangsu (3), Beijing (3), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shanghai INT Medical Instruments Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Elite Medtek(Jiangsu) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 9 |
| Tianjin Demax Medical Technology Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 5 |
| Boen Healthcare Co., Ltd. | Suzhou | Jiangsu | Specification developer | 263 |
| Zhejiang Mediunion Healthcare Group Co., Ltd. | Ningbo | Zhejiang | Contract manufacturer | 105 |
| Joykey Industrial (Pinghu) Limited | Pinghu | Zhejiang | Contract manufacturer | 43 |
| Sunny Medical Device (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 11 |
| Tianck Medical Co., Ltd. | Huizhou | Guangdong | Manufacturer | 10 |
| Lepu Medical Technology (Beijing) Co., Ltd. | Beijing | Beijing | Manufacturer | 7 |
| Beijing Target Medical Technologies Inc. | Beijing | Beijing | Contract manufacturer | 7 |
| Beijing Demax Medical Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 5 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
Showing 12 of 13. All 13 manufacturers in China registered for Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass
Record
| Listed by | Cook Incorporated, United States |
|---|---|
| FDA product code | DTL |
| Device type | Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass |
| Device class | Class 2 |
| Regulation | 21 CFR 870.4290 |
| Establishment | Contract manufacturer, Contract steriliser, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2017-08-22 |
| Record revised | 2020-03-05 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: Store in dark, dry, cool place. |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| G06002 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| DeRoyal | Deroyal Industries, Inc. | 171 |
| Namic | Medline Industries, Inc. | 170 |
| Namic | Navilyst Medical, Inc. | 165 |
| Merit® Manifold | Merit Medical Systems, Inc. | 119 |
| Connector | LivaNova USA, Inc. | 70 |
| Medline Industries, Inc. | Medline Industries, Inc. | 62 |
| Demax | Beijing Demax Medical Technology Co., Ltd. | 60 |
| DLP® | Medtronic, Inc. | 51 |
| Marquis® Stopcock | Merit Medical Systems, Inc. | 40 |
| Cook | Cook Incorporated | 38 |
| Unbranded | Advance Medical Designs, Inc. | 30 |
| Contrast Line | Argon Medical Devices, Inc. | 25 |
Showing 12 of 127. All products under Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass
Recalls
6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2018-03-29 | Class II | Equipment maintenance | Cap-adapter assembly of the device may potentially not be adequately tightened, possibly leading to fluid leakage from or air aspiration into the connecting tube. | 6345 | 2019-04-09 |
| 2018-03-29 | Class II | Equipment maintenance | Cap-adapter assembly of the device may potentially not be adequately tightened, possibly leading to fluid leakage from or air aspiration into the connecting tube. | 304 | 2019-04-09 |
| 2018-03-29 | Class II | Equipment maintenance | Cap-adapter assembly of the device may potentially not be adequately tightened, possibly leading to fluid leakage from or air aspiration into the connecting tube. | 220 | 2019-04-09 |
| 2018-03-29 | Class II | Equipment maintenance | Cap-adapter assembly of the device may potentially not be adequately tightened, possibly leading to fluid leakage from or air aspiration into the connecting tube. | 220 | 2019-04-09 |
| 2018-03-29 | Class II | Equipment maintenance | Cap-adapter assembly of the device may potentially not be adequately tightened, possibly leading to fluid leakage from or air aspiration into the connecting tube. | 886 | 2019-04-09 |
| 2018-03-29 | Class II | Equipment maintenance | Cap-adapter assembly of the device may potentially not be adequately tightened, possibly leading to fluid leakage from or air aspiration into the connecting tube. | 554 | 2019-04-09 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.