Intersept®

Conn RED 6109 3/16 X 1/4 W/Luer LOCK20PK

Registry build 21.09.26
13manufacturers in China registered for this device type
16catalogue numbers in this listing
3510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Jiangsu (3), Beijing (3), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DTL
Manufacturer City Province Registered as Device types
Shanghai INT Medical Instruments Co., Ltd. Shanghai Shanghai Contract manufacturer 10
Elite Medtek(Jiangsu) Co., Ltd. Changzhou Jiangsu Contract manufacturer 9
Tianjin Demax Medical Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 5
Boen Healthcare Co., Ltd. Suzhou Jiangsu Specification developer 263
Zhejiang Mediunion Healthcare Group Co., Ltd. Ningbo Zhejiang Contract manufacturer 105
Joykey Industrial (Pinghu) Limited Pinghu Zhejiang Contract manufacturer 43
Sunny Medical Device (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 11
Tianck Medical Co., Ltd. Huizhou Guangdong Manufacturer 10
Lepu Medical Technology (Beijing) Co., Ltd. Beijing Beijing Manufacturer 7
Beijing Target Medical Technologies Inc. Beijing Beijing Contract manufacturer 7
Beijing Demax Medical Technology Co., Ltd. Beijing Beijing Manufacturer 5
Curatia Medical Limited Suzhou Jiangsu Specification developer 5

Showing 12 of 13. All 13 manufacturers in China registered for Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass

Record

Regulatory record for Intersept®
Listed by Medtronic, Inc., United States
FDA product code DTL
Device type Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass
Device class Class 2
Regulation 21 CFR 870.4290
Establishment Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K883956
Record published 2016-09-22
Record revised 2025-03-03 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Ethylene Oxide
Single use Yes
Label carries lot or batch number
Packaging Pack of 20
Distribution end date 2019-05-02

Catalogue Numbers

Catalogue numbers for Intersept®
Catalogue number Size Status
6137 6.4 MM Port Outer Diameter In distribution
6123 9.5 MM Port Outer Diameter In distribution
6111 6.4 MM Port Outer Diameter In distribution
6125 12.7 MM Port Outer Diameter Withdrawn
6107 9.5 MM Port Outer Diameter Withdrawn
6106 6.4 MM Port Outer Diameter Withdrawn
6113 12.7 MM Port Outer Diameter Withdrawn
6136 6.4 MM Port Outer Diameter Withdrawn
6109 6.4 MM Port Outer Diameter Withdrawn
6124 4.8 MM Port Outer Diameter Withdrawn
6130 6.4 MM Port Outer Diameter Withdrawn
6110 6.4 MM Port Outer Diameter Withdrawn
6117 15.9 MM Port Outer Diameter Withdrawn
6141 6.4 MM Port Outer Diameter Withdrawn
6131 9.5 MM Port Outer Diameter Withdrawn
6140 9.5 MM Port Outer Diameter Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
DeRoyal Deroyal Industries, Inc. 171
Namic Medline Industries, Inc. 170
Namic Navilyst Medical, Inc. 165
Merit® Manifold Merit Medical Systems, Inc. 119
Connector LivaNova USA, Inc. 70
Medline Industries, Inc. Medline Industries, Inc. 62
Demax Beijing Demax Medical Technology Co., Ltd. 60
DLP® Medtronic, Inc. 51
Marquis® Stopcock Merit Medical Systems, Inc. 40
Cook Cook Incorporated 38
Unbranded Advance Medical Designs, Inc. 30
Contrast Line Argon Medical Devices, Inc. 25

Showing 12 of 127. All products under Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K123448 2012-12-13
K122811 2012-10-12
K113845 2012-01-25

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2008-08-27 Not classified Process control Medtronic has identified an issue with the packaging for specific lots of the Medtronic Adjustable Valve and valves contained in the Attain Left Heart Delivery System kits. A small number of valve package seals could be compromised. 35,193 total 2011-05-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer