Tram®
Catalogue number 00884450312353, listed by Merit Medical Systems, Inc., United States, under Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass. 13 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (3), Beijing (3), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shanghai INT Medical Instruments Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Elite Medtek(Jiangsu) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 9 |
| Tianjin Demax Medical Technology Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 5 |
| Boen Healthcare Co., Ltd. | Suzhou | Jiangsu | Specification developer | 263 |
| Zhejiang Mediunion Healthcare Group Co., Ltd. | Ningbo | Zhejiang | Contract manufacturer | 105 |
| Joykey Industrial (Pinghu) Limited | Pinghu | Zhejiang | Contract manufacturer | 43 |
| Sunny Medical Device (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 11 |
| Tianck Medical Co., Ltd. | Huizhou | Guangdong | Manufacturer | 10 |
| Lepu Medical Technology (Beijing) Co., Ltd. | Beijing | Beijing | Manufacturer | 7 |
| Beijing Target Medical Technologies Inc. | Beijing | Beijing | Contract manufacturer | 7 |
| Beijing Demax Medical Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 5 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
Showing 12 of 13. All 13 manufacturers in China registered for Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass
Record
| Listed by | Merit Medical Systems, Inc., United States |
|---|---|
| FDA product code | DTL |
| Device type | Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass |
| Device class | Class 2 |
| Regulation | 21 CFR 870.4290 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2023-05-18 |
| Record revised | 2025-05-12 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Packaging | Pack of 4, pack of 10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 00884450312353 | Cable Length-48″ (122 cm) | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| DeRoyal | Deroyal Industries, Inc. | 171 |
| Namic | Medline Industries, Inc. | 170 |
| Namic | Navilyst Medical, Inc. | 165 |
| Merit® Manifold | Merit Medical Systems, Inc. | 119 |
| Connector | LivaNova USA, Inc. | 70 |
| Medline Industries, Inc. | Medline Industries, Inc. | 62 |
| Demax | Beijing Demax Medical Technology Co., Ltd. | 60 |
| DLP® | Medtronic, Inc. | 51 |
| Marquis® Stopcock | Merit Medical Systems, Inc. | 40 |
| Cook | Cook Incorporated | 38 |
| Unbranded | Advance Medical Designs, Inc. | 30 |
| Contrast Line | Argon Medical Devices, Inc. | 25 |
Showing 12 of 127. All products under Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K143429 | 2014-12-22 |
| K140475 | 2014-04-16 |
| K100319 | 2010-04-28 |
| K072556 | 2007-11-20 |
| K993057 | 1999-10-05 |
| K933084 | 1994-03-23 |
| K934123 | 1993-11-23 |
| K925419 | 1993-01-22 |
| K913161 | 1991-10-21 |
Recalls
4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-08-04 | Class II | Process change control | Hemostasis valve has a manufacturing defect and when used the valve cap may remain depressed, leading to potential leakage, which may result in procedure inconvenience and/or hemorrhage. | 217,141 | |
| 2025-07-25 | Class II | Employee error | Due to a manufacturing issue involving the silicone quad ring where the ring is deformed or otherwise damaged and may cause a foreign body in the fluid pathway. | 447 | |
| 2022-03-01 | Class II | Component change control | A design change made to a hemostasis valve to improve manufacturability caused an internal gap between the rotator and the Y-body, where the guidewire can get caught, resulting in difficulty advancing the guidewire through the device. This | 36445 | |
| 2022-03-01 | Class II | Component change control | A design change made to a hemostasis valve to improve manufacturability caused an internal gap between the rotator and the Y-body, where the guidewire can get caught, resulting in difficulty advancing the guidewire through the device. This | 58963 | |
| 2010-12-16 | Not classified | Packaging process control | Compromised sterility/weak or open seals. | 28,679 for all products | 2012-08-08 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.