Affinity Fusion™

Oxygenator CB811 Fusion Cortiva US

Registry build 21.09.26
1manufacturer
7catalogue numbers in this listing
16510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Registered in Guangdong.

Chinese manufacturers registered for FDA product code DTZ
Manufacturer City Province Registered as Device types
Lifemotion Medical Technology Co., Ltd. Shenzhen Guangdong Contract manufacturer 2

Record

Regulatory record for Affinity Fusion™
Listed by Medtronic, Inc., United States
FDA product code DTZ
Device type Oxygenator, Cardiopulmonary Bypass
Device class Class 2
Regulation 21 CFR 870.4350
Establishment Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K183490
Record published 2020-01-21
Record revised 2026-02-12 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Storage Storage environment humidity 30 to 75 % RH; Handling environment temperature up to 40 °C; Special storage condition: Store the product at room temperature.

Catalogue Numbers

Catalogue numbers for Affinity Fusion™
Catalogue number Size Status
CB811 In distribution
BB811 In distribution
CB811 In distribution
BB811 In distribution
BB811 In distribution
CB841 In distribution
CB811 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Oxygenator, Cardiopulmonary Bypass Medtronic, Inc. 1,281
Intersept™ Medtronic, Inc. 103
Inspire Sorin Group Italia SRL 14
Capiox®fx Terumo Corp. 14
Capiox®rx Terumo Corp. 13
Quantum Perfusion Blood Oxygenator with Integrated AF VT75-C2U Spectrum Medical Ltd 11
Lilliput Sorin Group Italia SRL 11
Abiomed Breethe OXY-1 System Breethe, Inc. 11
Kids Sorin Group Italia SRL 8
Affinity NT™ Medtronic, Inc. 8
QUADROX-i Maquet Cardiopulmonary GmbH 7
Capiox® FX Hollow Fiber Oxygenator w Integrated Arterial Filter w Hardshell Res. Terumo Cardiovascular Systems Corporation 6

Showing 12 of 69. All products under Oxygenator, Cardiopulmonary Bypass

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K241352 2024-06-12
K230640 2023-04-06
K203111 2021-09-16
K191444 2019-09-27
K191029 2019-05-17
K183490 2019-04-12
K183511 2019-03-18
K172984 2017-11-20
K172626 2017-10-25
K162896 2016-12-06
K162016 2016-09-21
K143073 2015-03-25
K142784 2014-10-24
K123314 2013-01-22
K122827 2012-12-14
K100645 2012-09-14

Recalls Naming This Product

8 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Affinity Fusion™
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Medtronic Perfusion Systems 510(k) number 2022-12-12 Class II Process change control An upward trend of complaints in which the Temperature Monitoring Adapter (TMA), located on the Affinity Fusion Oxygenator, had come loose from the oxygenator either during pre-procedure perfusion set-up or post-procedure when disassembling 2,937 units
Medtronic Perfusion Systems 510(k) number 2022-12-12 Class II Process change control An upward trend of complaints in which the Temperature Monitoring Adapter (TMA), located on the Affinity Fusion Oxygenator, had come loose from the oxygenator either during pre-procedure perfusion set-up or post-procedure when disassembling 90,220 units
Medtronic Perfusion Systems 510(k) number 2022-12-12 Class II Process change control An upward trend of complaints in which the Temperature Monitoring Adapter (TMA), located on the Affinity Fusion Oxygenator, had come loose from the oxygenator either during pre-procedure perfusion set-up or post-procedure when disassembling 1,340 units
Medtronic Perfusion Systems 510(k) number 2022-12-12 Class II Process change control An upward trend of complaints in which the Temperature Monitoring Adapter (TMA), located on the Affinity Fusion Oxygenator, had come loose from the oxygenator either during pre-procedure perfusion set-up or post-procedure when disassembling 4,462 units
Medtronic Perfusion Systems 510(k) number 2022-12-12 Class II Process change control An upward trend of complaints in which the Temperature Monitoring Adapter (TMA), located on the Affinity Fusion Oxygenator, had come loose from the oxygenator either during pre-procedure perfusion set-up or post-procedure when disassembling 63,278 units
Medtronic Perfusion Systems 510(k) number 2022-12-12 Class II Process change control An upward trend of complaints in which the Temperature Monitoring Adapter (TMA), located on the Affinity Fusion Oxygenator, had come loose from the oxygenator either during pre-procedure perfusion set-up or post-procedure when disassembling 40,498 units
Medtronic, Inc. 510(k) number 2016-11-16 Class II Process control Medtronic is initiating a voluntary product recall for specific lot numbers of the Affinity Fusion Oxygenators with Balance1 Biosurface. These are distributed as stand-alone devices, or as a combination unit with the Affinity Fusion Cardiot 5609 (663 US; 4946 OUS) 2017-08-01
Medtronic Perfusion Systems 510(k) number 2014-10-31 Class II Process control Medtronic initiated an Urgent Medical Device Recall for 66 distributed Affinity FusionTM Oxygenation Systems with Carmeda Bioactive Surface due to damaged heat exchangers.
Product affected by this issue is limited to model CB841 sold stand
66, UPDATE: 168 additional devices. 2015-08-11

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2013-07-17 Class II Process control Medtronic was notified that Edwards Lifesciences has initiated a product recall for the Rigid Suction Wand, model S099B. The Wands are included within certain Perfusion Tubing Packs that are manufactured and distributed by Medtronic. 217 2014-02-04
2011-12-14 Not classified Labeling design Instructions for Use for the DLP Single Stage Venous Cannulae are in the process of being updated. The current precaution statement referencing ventricular assist procedures will be identified as a contraindication in the updated Instructi 106 2014-05-22
2008-10-17 Not classified Error in labeling Medtronic has identified an issue with the labeling of the I-4500 Silicone Oxygenators (P/N 61399402655). Lot numbers of this oxygenator manufactured between August 2007 and September 2008 have an incorrect “Recommended maximum blood flow 408 2011-04-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer