enableCV Dual Stage Venous Drainage Cannula
enableCV Dual Stage Venous Drainage Cannula - TR3240OA
Who Else Makes It
Concentrated in Guangdong (2), Jiangsu (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Gcmedica Enterprise Ltd.(Wuxi) | Wuxi | Jiangsu | Contract manufacturer | 55 |
| Modern Medical Equipment Manufacturing Ltd. | Heng Li, Dongguan | Guangdong | Contract manufacturer | 26 |
| Modern Medical Equipment Manufacturing (Qing Yuan) Ltd | Qing Yuan | Guangdong | Contract manufacturer | 26 |
Record
| Listed by | Enablecv, LLC, United States |
|---|---|
| FDA product code | DWF |
| Device type | Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass |
| Device class | Class 2 |
| Regulation | 21 CFR 870.4210 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K120072 |
| Record published | 2026-02-14 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: Store sterile packaged device in a cool, dry place. |
| Packaging | Pack of 10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| TR3240O | 32/40 Fr. (10.6/13.3 mm) x 40 cm (16″) | In distribution |
| TR2838L | 28/38 Fr. (9.3/12.6 mm) X 40 cm (16″) | In distribution |
| TR3446L | 34/46 Fr. (11.3/15.3 mm) x 40 cm (16″) | In distribution |
| TR3240OA | 32/40 Fr. (10.6/13.3 mm) x 40 cm (16″) | In distribution |
| TR3651B | 36/51 Fr. (12.0/17.0 mm) x 40 cm (16″) | In distribution |
| TR3240L | 32/40 Fr. (10.6/13.3 mm) x 40 cm (16″) | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass | Medtronic, Inc. | 5,237 |
| DLP™ | Medtronic, Inc. | 804 |
| Bio-Medicus™ | Medtronic, Inc. | 223 |
| Pemco Inc | Pemco, Inc. | 137 |
| Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass | Maquet Cardiopulmonary GmbH | 135 |
| Venous cardiopulmonary bypass cannula | LivaNova USA, Inc. | 97 |
| Eopa™ | Medtronic, Inc. | 87 |
| Surge Cardiovascular | MED Michigan Holdings LLC | 80 |
| Arterial cardiopulmonary bypass cannula | LivaNova USA, Inc. | 79 |
| MC2™ | Medtronic, Inc. | 66 |
| Select Series® | Medtronic, Inc. | 63 |
| Edwards Lifesciences Aortic Perfusion Cannula | Edwards Lifesciences Technology Sarl | 52 |
Showing 12 of 372. All products under Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| SPS Sterilization, Inc | 510(k) number | 2018-03-07 | Class II | Labeling False and Misleading | The expiration date on the device labeling exceeds its actual validated shelf life because the sterilization process used does not have adequate support for the extended shelf life. | 10 units total | 2018-11-27 |
| SPS Sterilization, Inc | 510(k) number | 2018-03-07 | Class II | Labeling False and Misleading | The expiration date on the device labeling exceeds its actual validated shelf life because the sterilization process used does not have adequate support for the extended shelf life. | 5 units total | 2018-11-27 |
| SPS Sterilization, Inc | 510(k) number | 2018-03-07 | Class II | Labeling False and Misleading | The expiration date on the device labeling exceeds its actual validated shelf life because the sterilization process used does not have adequate support for the extended shelf life. | 5 units total | 2018-11-27 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2015-11-04 | Class II | Employee error | Edwards Lifesciences initiated a field action for the Thin-Flex Venous Cannula (Model TF292902A) because the connector size is incorrectly described in the Edwards product guide as 3/8 inch. The actual and correct connector size is 1/2 inch | 8,915 units | 2017-02-10 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.