EVO
3 catalogue numbers from Control Unit, listed by LivaNova Deutschland GmbH, Germany, under Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass. 3 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (2), Jiangsu (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Gcmedica Enterprise Ltd.(Wuxi) | Wuxi | Jiangsu | Contract manufacturer | 55 |
| Modern Medical Equipment Manufacturing Ltd. | Heng Li, Dongguan | Guangdong | Contract manufacturer | 26 |
| Modern Medical Equipment Manufacturing (Qing Yuan) Ltd | Qing Yuan | Guangdong | Contract manufacturer | 26 |
Record
| Listed by | LivaNova Deutschland GmbH, Germany |
|---|---|
| FDA product code | DWF |
| Device type | Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass |
| Device class | Class 2 |
| Regulation | 21 CFR 870.4210 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K082344 |
| Record published | 2021-05-14 |
| Record revised | 2024-05-07 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Control Unit | In distribution | |
| Occluder | In distribution | |
| Control Unit | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass | Medtronic, Inc. | 5,237 |
| DLP™ | Medtronic, Inc. | 804 |
| Bio-Medicus™ | Medtronic, Inc. | 223 |
| Pemco Inc | Pemco, Inc. | 137 |
| Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass | Maquet Cardiopulmonary GmbH | 135 |
| Venous cardiopulmonary bypass cannula | LivaNova USA, Inc. | 97 |
| Eopa™ | Medtronic, Inc. | 87 |
| Surge Cardiovascular | MED Michigan Holdings LLC | 80 |
| Arterial cardiopulmonary bypass cannula | LivaNova USA, Inc. | 79 |
| MC2™ | Medtronic, Inc. | 66 |
| Select Series® | Medtronic, Inc. | 63 |
| Edwards Lifesciences Aortic Perfusion Cannula | Edwards Lifesciences Technology Sarl | 52 |
Showing 12 of 372. All products under Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| LivaNova USA, Inc. | 510(k) number | 2010-06-18 | Not classified | PMA | Although accessories were designed for use with two models, the HLM C5 and the HLM S5, the submission that included references to the Mast Roller Pump, B-Care5, and the Electrical Venous Line Occluder accessories covered the new HLM S5 syst | 1 unit | 2010-07-21 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.