Venous Cardiopolmunary Bypass Cannula
35 catalogue numbers from RTS-11129, listed by Sorin Group Italia SRL, under Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass. 3 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (2), Jiangsu (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Gcmedica Enterprise Ltd.(Wuxi) | Wuxi | Jiangsu | Contract manufacturer | 55 |
| Modern Medical Equipment Manufacturing Ltd. | Heng Li, Dongguan | Guangdong | Contract manufacturer | 26 |
| Modern Medical Equipment Manufacturing (Qing Yuan) Ltd | Qing Yuan | Guangdong | Contract manufacturer | 26 |
Record
| Listed by | Sorin Group Italia SRL |
|---|---|
| FDA product code | DWF |
| Device type | Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass |
| Device class | Class 2 |
| Regulation | 21 CFR 870.4210 |
| 510(k) | K943934 |
| Record published | 2025-12-19 |
| Record revised | 2026-03-19 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Packaging | Case of 10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| RTS-11129 | In distribution | |
| RDS-61134 | In distribution | |
| RDS-61046 | In distribution | |
| RDS-61146 | In distribution | |
| RV-40020 | In distribution | |
| RV-40022 | In distribution | |
| RV-41028 | In distribution | |
| RDS-61037 | In distribution | |
| RV-41024 | In distribution | |
| RV-41030 | In distribution | |
| RV-41032 | In distribution | |
| RV-40030 | In distribution | |
| RV-41020 | In distribution | |
| RV-40024 | In distribution | |
| RV-41034 | In distribution | |
| RV-41026 | In distribution | |
| RV-40028 | In distribution | |
| RTS-13029 | In distribution | |
| RV-40536 | In distribution | |
| RV-41036 | In distribution | |
| RV-40034 | In distribution | |
| RDS-61137 | In distribution | |
| RV-40018 | In distribution | |
| RV-41018 | In distribution | |
| RV-41022 | In distribution | |
| RV-40036 | In distribution | |
| RV-40026 | In distribution | |
| RDS-61150 | In distribution | |
| RTS-13129 | In distribution | |
| RDS-61140 | In distribution | |
| RV-40016 | In distribution | |
| RDS-61040 | In distribution | |
| RTS-11029 | In distribution | |
| RDS-61034 | In distribution | |
| RV-40032 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass | Medtronic, Inc. | 5,237 |
| DLP™ | Medtronic, Inc. | 804 |
| Bio-Medicus™ | Medtronic, Inc. | 223 |
| Pemco Inc | Pemco, Inc. | 137 |
| Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass | Maquet Cardiopulmonary GmbH | 135 |
| Venous cardiopulmonary bypass cannula | LivaNova USA, Inc. | 97 |
| Eopa™ | Medtronic, Inc. | 87 |
| Surge Cardiovascular | MED Michigan Holdings LLC | 80 |
| Arterial cardiopulmonary bypass cannula | LivaNova USA, Inc. | 79 |
| MC2™ | Medtronic, Inc. | 66 |
| Select Series® | Medtronic, Inc. | 63 |
| Edwards Lifesciences Aortic Perfusion Cannula | Edwards Lifesciences Technology Sarl | 52 |
Showing 12 of 372. All products under Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| LivaNova USA, Inc. | 510(k) number | 2017-06-09 | Class II | Process control | Identification of excess plastic on the tip of the cannula. | 105,770 units | 2023-11-09 |
| LivaNova USA, Inc. | 510(k) number | 2016-08-12 | Class II | Process control | Sorin Group USA, Inc. announces a voluntary field for the Aortic Arch Cannula and Coronary Artery Perfusion Cannula With Ballon because the tip of the cannula should be bent at either a 45 or 90 degree angle. Samples have been returned wher | 200 units worldwide | 2017-03-27 |
| LivaNova USA, Inc. | 510(k) number | 2016-06-22 | Class II | Process control | Sorin Group USA is recalling Aortic Arch Cannulae (part numbers NA-55X7 and NA-55X8) because the distal end may be less than specified. The defective cannula are showing an angle that is about 15-20 degrees instead of approximately 45 degr | 5740 | 2017-03-27 |
| LivaNova USA, Inc. | 510(k) number | 2016-01-25 | Class II | Employee error | Sorin Group initiated field correction for the Dual Stage Venous Return Catheter because the incorrect Instructions For Use (IFU) was packaged in the case. | 60 | 2016-10-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.