Accessrail Platform (Deep Blade)

Catalogue number DB-1000, listed by Maquet Cardiovascular LLC, United States, under Instruments, Surgical, Cardiovascular. 6 manufacturers in China are registered for this product code.

Registry build 21.09.26
6manufacturers in China registered for this device type
1catalogue number
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (1), Shandong (1).

Chinese manufacturers registered for FDA product code DWS
Manufacturer City Province Registered as Device types
Shanghai Medical Instruments (Group) Ltd. Corp. Shanghai Shanghai Contract manufacturer 235
Xinhua Surgical Instrument Co., Ltd. Zibo Shandong Manufacturer 222
Asol Co., Ltd. Huaian Jiangsu Manufacturer 22
Huaian Tisurg Medical Instruments Co., Ltd. Huaian Jiangsu Contract manufacturer 22
Huaian Wolfram Surgical Instruments Huaian Jiangsu Manufacturer 14
Global Medical Production Co., Ltd. Jiaxing Zhejiang Manufacturer 10

Record

Regulatory record for Accessrail Platform (Deep Blade)
Listed by Maquet Cardiovascular LLC, United States
FDA product code DWS
Device type Instruments, Surgical, Cardiovascular
Device class Class 1
Regulation 21 CFR 870.4500
Establishment Specification developer, Manufacturer
Premarket notification Exempt
Record published 2016-09-24
Record revised 2021-04-13 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Accessrail Platform (Deep Blade)
Catalogue number Size Status
DB-1000 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Delacroix-Chevalier Landanger 1,819
Landanger Landanger 1,213
Ambler Surgical Ambler Surgical, LLC 1,013
Pilling Teleflex Medical LLC 971
Wexler Surgical, Inc. Wexler Surgical, Inc. 876
V. Mueller Steris Corporation 716
Novo Surgical Novo Surgical, Inc. 387
Integra® Jarit® Integra LifeSciences Production Corporation 364
Instruments, Surgical, Cardiovascular Fehling Instruments GmbH 352
Novo Surgical Inc. Novo Surgical, Inc. 290
Avalign Avalign Technologies, Inc. 283
Millennium Avalign Technologies, Inc. 272

Showing 12 of 472. All products under Instruments, Surgical, Cardiovascular

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2023-06-28 Class II Nonconforming Material/Component The Standard Blade may not securely latch onto the Activator Drive. This may result in the inability to stabilize and position or may result in the loss of stabilization and positioning of heart, release of device component into the patient 594 units
2023-06-28 Class II Nonconforming Material/Component The Standard Blade may not securely latch onto the Activator Drive. This may result in the inability to stabilize and position or may result in the loss of stabilization and positioning of heart, release of device component into the patient 401 units
2023-06-28 Class II Nonconforming Material/Component The Standard Blade may not securely latch onto the Activator Drive. This may result in the inability to stabilize and position or may result in the loss of stabilization and positioning of heart, release of device component into the patient 785 units
2023-06-28 Class II Nonconforming Material/Component The Standard Blade may not securely latch onto the Activator Drive. This may result in the inability to stabilize and position or may result in the loss of stabilization and positioning of heart, release of device component into the patient 334 units
2022-02-09 Class II Mixed-up of materials/components Potential for corrosion on the pins of the Ultima Activator II Reusable Drive Mechanism. Harms may include allergic reaction, metal toxicity, and other delayed responses. 60

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer