Edwards Lifesciences Vascular Torniquet Kit

Vascular Torniquet Kit

Registry build 21.09.26
10manufacturers in China registered for this device type
1catalogue number
5510(k) clearances naming this product code
8recalls on this code

Who Else Makes It

Concentrated in Beijing (3), Zhejiang (2), Guangdong (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DXC
Manufacturer City Province Registered as Device types
Suzhou Meccan Import and Export Corp. Suzhou Jiangsu Contract manufacturer 71
Shanghai INT Medical Instruments Co., Ltd. Shanghai Shanghai Contract manufacturer 10
Tianjin Demax Medical Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 5
Wickimed (Huizhou) Medical Equipment Manufacturing Co., Ltd. Huizhou Guangdong Contract manufacturer 3
Joykey Industrial (Pinghu) Limited Pinghu Zhejiang Contract manufacturer 43
Sunny Medical Device (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 11
Lepu Medical Technology (Beijing) Co., Ltd. Beijing Beijing Manufacturer 7
Terumo Medical Products (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 7
Beijing Target Medical Technologies Inc. Beijing Beijing Contract manufacturer 7
Beijing Demax Medical Technology Co., Ltd. Beijing Beijing Manufacturer 5

Record

Regulatory record for Edwards Lifesciences Vascular Torniquet Kit
Listed by Edwards Lifesciences Technology Sarl, United States
FDA product code DXC
Device type Clamp, Vascular
Device class Class 2
Regulation 21 CFR 870.4450
Establishment Contract manufacturer, Specification developer, Manufacturer
510(k) K910221
Record published 2016-08-31
Record revised 2022-04-08 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging Shipper of 10

Catalogue Numbers

Catalogue numbers for Edwards Lifesciences Vascular Torniquet Kit
Catalogue number Size Per pack Status
TK2 2 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Millennium Avalign Technologies, Inc. 831
Novo Surgical Novo Surgical, Inc. 708
Ambler Surgical Ambler Surgical, LLC 575
Pilling Teleflex Medical LLC 544
Avalign Avalign Technologies, Inc. 543
Boss Instruments Boss Instruments, Ltd. 457
V. Mueller Steris Corporation 432
Wexler Surgical, Inc. Wexler Surgical, Inc. 342
Integra® Jarit® Integra LifeSciences Production Corporation 331
Scanlan® Scanlan International, Inc. 294
HNM Medical HNM Stainless, LLC. 230
Aesculap Aesculap AG 136

Showing 12 of 639. All products under Clamp, Vascular

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K260105 2026-06-05
K163693 2017-01-26
K132175 2013-09-13
K113182 2011-12-07
K112694 2011-10-14

Recalls

1 of these is Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-05-14 Class I Device Design Possibility of balloon rupture in intra-aortic occlusion devices. If the balloon bursts during cardiopulmonary bypass, the heart can fill and warm, the operative site may be obscured, and the device will need to be exchanged or operative s 6552 2024-04-23
2019-01-16 Class II Process control Edwards Lifesciences has received a limited number of customer reports regarding an inter-lumen leak between the cardioplegia lumen and pressure lumen in the device. 2715 units
2018-03-30 Class II Under Investigation by firm Possible leak at distal open end of the strain relief, which causes medical staff to continue adding inflation fluid to maintain balloon pressure for adequate occlusion of the ascending aorta. 3,052 units total 2023-11-29
2015-05-05 Class II Device Design Potential device damage on the strain relief near the hub area, which may result in blood leakage. 3,360 units. 2017-12-12
2009-09-24 Not classified Process control Balloon catheters were spontaneously rupturing during use. 2,737 total 2012-04-25
2009-09-24 Not classified Process control Spontaneous balloon rupture during use of the product. 2,737 total 2012-04-25
2008-11-26 Not classified Nonconforming Material/Component Balloon rupture: Catheter balloon may rupture during cardiopulmonary bypass procedure. For further information, please telephone Edwards Lifesciences Research Medical, Inc. at 801-565-6173. 1267 units 2011-08-10
2008-11-26 Not classified Nonconforming Material/Component Balloon rupture: Catheter balloon may rupture during cardiopulmonary bypass procedure. For further information, please telephone Edwards Lifesciences Research Medical, Inc. at 801-565-6173. 963 units 2011-08-10

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer