Heartstring III System 4.3MM
Catalogue number HSK-3043, listed by Maquet Cardiovascular LLC, United States, under Clamp, Vascular. 10 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Beijing (3), Zhejiang (2), Guangdong (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Suzhou Meccan Import and Export Corp. | Suzhou | Jiangsu | Contract manufacturer | 71 |
| Shanghai INT Medical Instruments Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Tianjin Demax Medical Technology Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 5 |
| Wickimed (Huizhou) Medical Equipment Manufacturing Co., Ltd. | Huizhou | Guangdong | Contract manufacturer | 3 |
| Joykey Industrial (Pinghu) Limited | Pinghu | Zhejiang | Contract manufacturer | 43 |
| Sunny Medical Device (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 11 |
| Lepu Medical Technology (Beijing) Co., Ltd. | Beijing | Beijing | Manufacturer | 7 |
| Terumo Medical Products (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 7 |
| Beijing Target Medical Technologies Inc. | Beijing | Beijing | Contract manufacturer | 7 |
| Beijing Demax Medical Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 5 |
Record
| Listed by | Maquet Cardiovascular LLC, United States |
|---|---|
| FDA product code | DXC |
| Device type | Clamp, Vascular |
| Device class | Class 2 |
| Regulation | 21 CFR 870.4450 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K130382 |
| Record published | 2016-09-24 |
| Record revised | 2025-02-06 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Sizes | Outer diameter 4.3 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| HSK-3043 | Outer Diameter 4.3 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Millennium | Avalign Technologies, Inc. | 831 |
| Novo Surgical | Novo Surgical, Inc. | 708 |
| Ambler Surgical | Ambler Surgical, LLC | 575 |
| Pilling | Teleflex Medical LLC | 544 |
| Avalign | Avalign Technologies, Inc. | 543 |
| Boss Instruments | Boss Instruments, Ltd. | 457 |
| V. Mueller | Steris Corporation | 432 |
| Wexler Surgical, Inc. | Wexler Surgical, Inc. | 342 |
| Integra® Jarit® | Integra LifeSciences Production Corporation | 331 |
| Scanlan® | Scanlan International, Inc. | 294 |
| HNM Medical | HNM Stainless, LLC. | 230 |
| Aesculap | Aesculap AG | 136 |
Showing 12 of 639. All products under Clamp, Vascular
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Maquet Cardiovascular LLC | 510(k) number | 2025-08-15 | Class II | Under Investigation by firm | Three failure modes have been identified: failure of the Heartstring Seal to load, failure of the Heartstring Seal to deploy into the aortotomy, and failure of the deployed Heartstring Seal to provide adequate hemostasis. | 126 units (91 US, 35 OUS) |
| Maquet Cardiovascular LLC | 510(k) number | 2025-08-15 | Class II | Under Investigation by firm | Three failure modes have been identified: failure of the Heartstring Seal to load, failure of the Heartstring Seal to deploy into the aortotomy, and failure of the deployed Heartstring Seal to provide adequate hemostasis. | 28,331 units (16,615 US, 11,716 OUS) |
| Maquet Cardiovascular LLC | 510(k) number | 2025-08-15 | Class II | Under Investigation by firm | Three failure modes have been identified: failure of the Heartstring Seal to load, failure of the Heartstring Seal to deploy into the aortotomy, and failure of the deployed Heartstring Seal to provide adequate hemostasis. | 12,471 units (6,565 US, 5,906 OUS) |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2010-05-05 | Not classified | Process design | Deployment tube may detach during use due to insufficient adhesive, which may result in product failure to operate. | 1630 | 2011-06-21 |