Turbo-Power Laser Atherectomy Catheter

The Turbo-Power Laser Atherectomy Catheter delivers ultraviolet laser energy to obstructing tissue in peripheral arteries. Optical fibres carry energy from a compatible laser console to the…

Registry build 21.09.26

The Turbo-Power Laser Atherectomy Catheter delivers ultraviolet laser energy to obstructing tissue in peripheral arteries. Optical fibres carry energy from a compatible laser console to the catheter tip, where it breaks down lesion material. The catheter combines this fibre assembly with a motor drive unit.

It is used for new or recurrent lesions in native arteries below the groin and for restenosis within bare nitinol stents in the femoropopliteal arteries, with adjunctive balloon angioplasty. The 2.0 and 2.3 millimetre catheters are used in vessels with reference diameters of at least 3 millimetres.

Compatibility and Placement

The catheter is compatible with the CVX-300 Excimer Laser System and Philips Laser System. It tracks over a 0.018 inch guidewire and has a radiopaque distal marker. Each catheter is supplied sterile for a single prescription use.

3manufacturers in China registered for this device type
4catalogue numbers in this listing
10510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

All of them in Guangdong. 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MCW
Manufacturer City Province Registered as Device types
ATL Technology DG,Ltd. Dongguan Guangdong Contract manufacturer 14
Quasar Electronics Technology (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 2
Dongguan King Medical Technology Co., Ltd. Dongguan Guangdong Contract manufacturer 14

Record

Regulatory record for Turbo-Power Laser Atherectomy Catheter
Listed by Spectranetics Corp., United States
FDA product code MCW
Device type Catheter, Peripheral, Atherectomy
Device class Class 2
Regulation 21 CFR 870.4875
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K222837
Record published 2018-11-29
Record revised 2024-10-21 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Storage Special storage condition: Keep Dry
Sizes Outer diameter 2 to 2.3 mm; length 125 to 150 cm; lumen/inner diameter 0.018 in

Catalogue Numbers

Catalogue numbers for Turbo-Power Laser Atherectomy Catheter
Catalogue number Size Status
423-050 Outer Diameter 2.3 mm In distribution
420-050 Outer Diameter 2.0 mm In distribution
423-050 Outer Diameter 2.3 mm In distribution
420-050 Outer Diameter 2.0 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Diamondback Peripheral Cardiovascular Systems Incorporated 44
Turbo-Elite™ Spectranetics Corp. 24
Stealth Cardiovascular Systems Incorporated 20
Zilient Cardiovascular Systems Incorporated 16
TurboHawk Covidien LP 15
HawkOne Covidien LP 14
Turbo-Elite Laser Atherectomy Catheter Spectranetics Corp. 12
SilverHawk Covidien LP 11
Auryon Atherectomy Catheter Eximo Medical Ltd 10
Revolution Peripheral Atherectomy System Rex Medical 8
Peripheral RotaLink® Plus Boston Scientific Corporation 8
SilverHawkTM Covidien LP 8

Showing 12 of 102. All products under Catheter, Peripheral, Atherectomy

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K250385 2025-03-13
K222837 2022-12-08
K180694 2018-04-05
K172687 2017-11-27
K170059 2017-04-07
K162561 2017-01-05
K152181 2015-11-12
K140775 2014-07-23
K123632 2013-01-25
K094036 2010-01-25

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-11-25 Class II Device Design Due to complaints received for the marker band detaching from the distal tip of the catheter and remaining in the patient as laser catheter was retracted. 40,276 catheters
2023-11-15 Class II Packaging process control Incorrect product labeling. Exterior product box label does not match internal pouch label. 1,239 catheters
2017-06-06 Class II Device Design Potential for flouroscopially visible marker band at the tip of the Rapid Exchange Turbo Elite Atherectomy Catheters to become loose or disengaged rom the catheter when the device is in use in an off-label manner. 2021-07-08
2016-10-31 Class II Packaging Spectranetics Corporation announces a voluntary field action for the Turbo Elite Atherectomy Catheter, ELCA Coronary Atherectomy Catheter, and Bridge Occlusion Balloon due to potentially compromised integrity of the outer sterile packaging. 14,624 units 2017-04-18
2016-01-15 Class II Error in labeling The product is labeled with an expiration date that is past its shelf life. 8 units 2017-03-02

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer