Acrobat V Stabilizer

Acrobat V Vacuum Off-Pump System

Registry build 21.09.26
9manufacturers in China registered for this device type
1catalogue number
8recalls on this code

Who Else Makes It

Concentrated in Guangdong (3), Beijing (3), Jiangsu (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MWS
Manufacturer City Province Registered as Device types
Jiangsu Guangda Medical Material Group Co., Ltd. Haian Jiangsu Contract manufacturer 32
Modern Medical Equipment Manufacturing Ltd. Heng Li, Dongguan Guangdong Contract manufacturer 26
Maquet (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 6
Modern Medical Equipment Manufacturing (Qing Yuan) Ltd Qing Yuan Guangdong Contract manufacturer 26
Bothwin (Beijing) Medical Technology Co., Ltd. Beijng Beijing Manufacturer 25
Global Medical Production Co., Ltd. Jiaxing Zhejiang Manufacturer 10
Beijing Hangtian Kadi Technology R&D Institute Beijing Beijing Manufacturer 5
Sumitomo Bakelite (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 3
Beijing Yuewei Medical Technology Co., Ltd. Beijing Beijing Manufacturer 2

Record

Regulatory record for Acrobat V Stabilizer
Listed by Maquet Cardiovascular LLC, United States
FDA product code MWS
Device type Stabilizer, Heart
Device class Class 1
Regulation 21 CFR 870.4500
Establishment Specification developer, Manufacturer
Premarket notification Exempt
Record published 2016-09-24
Record revised 2026-06-19 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Distribution end date 2025-12-31

Catalogue Numbers

Catalogue numbers for Acrobat V Stabilizer
Catalogue number Size Status
OM-9100S Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Octopus® Medtronic, Inc. 11
Heart Stabilizer Finger Attachment Sontec Instruments, Inc. 6
Heartline Stabilizer Arm Sontec Instruments, Inc. 6
Starfish™ Medtronic, Inc. 4
Stabilizer Tips Sontec Instruments, Inc. 4
Urchin® Medtronic, Inc. 3
Acrobat-I Stabilizer Maquet Cardiovascular LLC 2
Viper II Heart Stabilizer KDL Medical, Inc. 2
Viper II Apical Lift KDL Medical, Inc. 2
Acrobat-i Positioner Maquet Cardiovascular LLC 2
Acrobat SUV Stabilizer Maquet Cardiovascular LLC 2
Starfish® EVO Medtronic, Inc. 2

Showing 12 of 36. All products under Stabilizer, Heart

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of Acrobat V Stabilizer
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Maquet Cardiovascular LLC UDI-DI 2023-06-28 Class II Nonconforming Material/Component The Standard Blade may not securely latch onto the Activator Drive. This may result in the inability to stabilize and position or may result in the loss of stabilization and positioning of heart, release of device component into the patient 594 units

Recalls

6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-10-16 Class II Process change control Deviations in the manufacturing process created a compromise in the sterile barrier, in which sterility cannot be assured during the duration of the product’s 2-year shelf life. 10,778 units
2024-10-16 Class II Process change control Deviations in the manufacturing process created a compromise in the sterile barrier, in which sterility cannot be assured during the duration of the product’s 2-year shelf life. 33,823 units
2024-10-16 Class II Process change control Deviations in the manufacturing process created a compromise in the sterile barrier, in which sterility cannot be assured during the duration of the product’s 2-year shelf life. 14,338 units
2023-10-31 Class II Component design/selection The Positioner Arm may not tighten or lock during normal use. 6472 units
2023-09-13 Class II Device Design Housing Mount Jaw of these devices breaking during normal use and may result in injury to the epicardial tissue or vasculature, or a coronary artery or previously placed bypass graft, or could result in procedural delay and/or conversion. 2951 units
2014-08-13 Class II Package design/selection An internal finding identified the presence of pinholes/cuts in some of the Tyvek pouches of the vacuum tubing sets included as an accessory to Acrobat V Vacuum Off-Pump System, Acrobat SUV Vacuum Off-Pump System, Axius XPOSE 3 Access Devic 16,532 units (19,270 units international) 2016-03-30
2011-11-16 Not classified Employee error There may be a small perforation in the sterile pouch of select lots of the ACROBAT V, ACROBAT SUV, and ACROBAT Mechanical Stabilizers and the XPOSE 3 and XPOSE 4 Positioners. 9436 unit total (US AND WORLDWIDE) 2014-01-10
2011-11-16 Not classified Employee error There may be a small perforation in the sterile pouch of select lots of the ACROBAT V, ACROBAT SUV, and ACROBAT Mechanical Stabilizers and the XPOSE 3 and XPOSE 4 Positioners. 9436 unit total (US AND WORLDWIDE) 2014-01-10

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer