Altrix Temperature Management Wraps
Altrix Temperature Management Wraps transfer heat to or from a patient through circulating temperature-controlled water. They are patient-contact accessories for the Altrix controller and…
Altrix Temperature Management Wraps transfer heat to or from a patient through circulating temperature-controlled water. They are patient-contact accessories for the Altrix controller and wrap around the torso or thigh.
Layers of polymer film, nonwoven material and insulation are sealed together to form water channels. Insulated tubing connects the wrap to the controller through hoses.
Thermal Regulation
Water flowing through the channels warms or cools by conduction across the patient-contact surface. The controller regulates the circulating water as part of the prescribed temperature-management therapy. The wraps are supplied nonsterile and are used in adult or pediatric clinical temperature-management applications.
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (1), Anhui (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Sino Protection (Hefei) Medical Products Co., Ltd. | Hefei | Anhui | Contract manufacturer | 18 |
| Jiangyin Sinbon Electronics Co Ltd | Jiangyin | Jiangsu | Contract manufacturer | 13 |
| Copious Intl., Inc. | Heyuan, Guangdong Province | Contract manufacturer | 11 | |
| Jiangyin Puremed | Jiangyin | Jiangsu | Contract manufacturer | 7 |
| Betacera Inc. | Suzhou | Jiangsu | Contract manufacturer | 3 |
| Shanghai Xodus Medical Company Limited | Shanghai | Shanghai | Specification developer | 25 |
| Hangzhou Tappa Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 3 |
| Jiangmen Dacheng Medical Equipment Co., Ltd. | Jiangmen | Guangdong | Contract manufacturer | 1 |
Record
| Listed by | Stryker GmbH, Switzerland |
|---|---|
| FDA product code | DWJ |
| Device type | System, Thermal Regulating |
| Device class | Class 2 |
| Regulation | 21 CFR 870.5900 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K171149 |
| Record published | 2020-09-29 |
| Record revised | 2026-01-09 (version 3) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment atmospheric pressure 50 to 106 KiloPascal; Storage environment temperature -40 to 60 °C; Handling environment temperature -29 to 60 °C; Handling environment humidity 25 to 95 % RH; Storage environment humidity 10 to 95 % RH |
| Packaging | Case of 5 |
| Distribution end date | 2025-06-20 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 8003-003-103 | In distribution | |
| 8003-002-102 | In distribution | |
| 3008-002-106 | In distribution | |
| 8003-002-103 | In distribution | |
| 8003-002-105 | In distribution | |
| 8003-003-101 | In distribution | |
| 8003-002-101 | In distribution | |
| 8003-002-104 | In distribution | |
| 8003-003-104 | In distribution | |
| 8003-003-102 | In distribution | |
| 8003-002-002 | Withdrawn | |
| 8003-003-002 | Withdrawn | |
| 8003-002-004 | Withdrawn | |
| 8003-002-005 | Withdrawn | |
| 8003-002-006 | Withdrawn | |
| 8003-003-004 | Withdrawn | |
| 8003-002-003 | Withdrawn | |
| 8003-003-001 | Withdrawn | |
| 8003-003-003 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Mistral-Air | The Surgical Company International B.V. | 114 |
| Bair Hugger™ | 3M Company | 99 |
| IOB | Jiangmen Dacheng Medical Equipment Co., Ltd. | 68 |
| IOB | Iob Medical, Inc. | 61 |
| 3M™ Bair Hugger™ | 3M Company | 61 |
| Cocoon | Care Essentials PTY Ltd | 59 |
| Soft Air | Adroit Medical Systems, Inc. | 56 |
| Level 1 | ICU Medical, Inc | 49 |
| System, Thermal Regulating | Hangzhou Tappa Medical Technology Co., Ltd. | 47 |
| PremierPro | Prestige Ameritech | 39 |
| Bair Paws™ | 3M Company | 30 |
| SourceMark | Sourcemark, LLC. | 25 |
Showing 12 of 166. All products under System, Thermal Regulating
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K180834 | 2018-08-10 |
| K171149 | 2017-07-18 |
| K152266 | 2016-12-02 |
Recalls
4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2018-09-06 | Class II | Software design | Users may experience alarm fatigue due to frequent alarming relating to patient temperature deviation beyond 0.5C while in Automatic mode. 2. Users may experience a Remove from Use code 9 (RFU 9) fault condition relating to inadvertent flow | 389 units | 2020-04-13 |
| 2017-07-21 | Class II | Component design/selection | It was identified that the Mistral-Air Premium blankets may be capable of conducting electricity during a defibrillation or cardioversion therapy at higher energy levels (70 Joules or more) when the blanket is applied with the reflective si | 11160 | 2018-03-22 |
| 2017-03-29 | Class II | Software design | The water may reheat too quickly if the unit is in “Automatic” mode, switched to “Manual” mode to view water temperature, and then switched back to “Automatic” mode. | 119 | 2017-09-18 |
| 2013-12-27 | Class II | Device Design | Stryker Medical has identified that on some units of the MTA7900, there is a lack of a water temperature display while the unit is in Auto mode. While in Auto mode, only the patient temperature is displayed along with the set point. The wa | 1002 units | 2014-11-04 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.